VRL01 / VRL02 / VRL03 RCBO - أحادي القطب + محايد (1P+N) 6-50A

  • rcbo أحادي القطب (1P+N) modular RCBO for single-phase branches, In 6–50A, tripping curves ب/ج.

  • النوع AC/النوع A, ، الحساسيات IΔn 10 / 30 / 100 / 300 mA; Icn 6 kA / 10 kA @ 240 V, ، 50/60 هرتز.

  • Certified SEMKO / UKCA / CE; standard IEC/EN 61009-1; front test button, DIN-rail mounting.

احصل على عرض أسعار

التصنيف:

rcbo أحادية القطب VRL01 / VRL02 / VRL03 integrates residual-current and overcurrent protection in a compact 1P+N format, rated 6–50 A for 240 V, 50/60 Hz systems with Type AC/A and multiple IΔn options.

لمحة عامة

The VRL01 / VRL02 / VRL03 family is designed for single-phase distribution branches where
reliable residual-current protection and coordinated overcurrent performance are required.
Each variant shares the same 1P+N footprint and broad current range up to 50 A, with
selectable tripping curves (B/C), multiple residual sensitivities, and high breaking
capacity options (6/10 kA) to match fault levels on 240 V systems.

الميزات الرئيسية

  • عامل الشكل: 1ص+ن (single-pole + neutral)
  • التيار المقدر (في): 6–50 A (typical steps: 6/10/16/20/25/32/40/50 A)
  • الجهد المقنن (Ue): تيار متردد 240 فولت, 50/60 Hz
  • نوع التيار المتبقي: النوع AC/النوع A
  • الحساسيات (IΔn): 10 / 30 / 100 / 100 / 300 مللي أمبير
  • MCB tripping curves: ب (3-5×في) و C (5-10×10×في)
  • سعة الانكسار (Icn): 6 kA / 10 kA @ 240 V
  • Front test button (T); DIN-rail mounting; front wiring
  • Compliance & certification: IEC/EN 61009-1; SEMKO, UKCA, CE

RCBO Single Pole Technical Data — VRL01 / VRL02 / VRL03

المعلمةVRL01VRL02VRL03
الأعمدة1P+N (قطب واحد + محايد)
التيار المقدر (في)6–50 A6–50 A6–50 A
الجهد المقنن (Ue)تيار متردد 240 فولتتيار متردد 240 فولتتيار متردد 240 فولت
التردد50/60 هرتز
نوع التيار المتبقيالنوع AC/النوع A
التيار المتبقي المقدر (IΔn)10 / 30 / 100 / 100 / 300 مللي أمبير
منحنى تعثر MCBب: 3-5 × بوصة؛ ج: 5-10 × بوصة
سعة الانكسار (Icn)6 kA / 10 kA @ 240 V6 kA / 10 kA @ 240 V6 kA / 10 kA @ 240 V
التركيبالسكة الحديدية DIN؛ الأسلاك الأمامية؛ زر الاختبار (T)
الاستخدام الموصى بهResidential & commercial branches (lighting / sockets) within 1P+N and ≤50 A
المعاييرIEC/EN 61009-1
الشهاداتSEMKO, UKCA, CE

التطبيقات

  • Apartments & houses: lighting/socket circuits up to 50 A
  • Commercial offices & retail: small-to-medium branch protection
  • Public facilities: classrooms, admin areas, auxiliary circuits
 

المعايير والامتثال

Conforms to IEC/EN 61009-1 with certifications SEMKO, UKCA, CE.
Coordinate with upstream protective devices; follow local codes for selectivity and fault levels.

الأسئلة الشائعة

Do VRL01, VRL02 and VRL03 differ in core protection features?

All three share the same 1P+N format, 6–50 A range, Type AC/A residual options and B/C curves. They are part of the same platform with high breaking-capacity options (6/10 kA) for 240 V systems.

Which sensitivity (IΔn) should be used for sockets and lighting?

30 mA is most common for socket/lighting circuits. 10 mA is for higher touch-safety; 100/300 mA may be used per coordination and local code requirements.

How to choose between curve B and curve C?

استخدم المنحنى B (3-5 × بوصة) للأحمال المقاومة/الحثية الخفيفة؛ استخدم المنحنى C (5-10 × بوصة) للدوائر ذات التدفق العالي مثل المحركات أو المحولات.