VDL01 RCBO Circuit Breaker — 2P/4P Adjustable Residual Current Protection (up to 90A)

  • rcbo circuit breaker VDL01 with 2P/4P options and adjustable current pairs (5/15A → 60/90A), designed for mains/feeder protection.

  • Normal & Type S (time-delay) residual protection with IΔn 300 mA / 500 mA, coordinated selectivity for upstream devices.

  • Icn 3 kA, 230/240 V & 400/415 V, digital current display, anti-tamper design; built to NF C 61450 / NF C 62411 / IEC 61009.

احصل على عرض أسعار

التصنيف:

rcbo circuit breaker VDL01 is a two- or four-pole adjustable device combining residual-current and overcurrent protection for mains and feeder circuits, with selectable Normal and Type S (time-delay) characteristics.

لمحة عامة

VDL01 integrates residual-current and overcurrent protection into a compact 2P/4P form.
It features adjustable current pairs to match upstream/downstream coordination and
offers Normal و Type S (time-delay) residual functions with higher
sensitivities (IΔn 300 mA / 500 mA) suitable for main/feeder selectivity.
A digital current display and anti-tamper design improve on-site setting and security.

الميزات الرئيسية

  • Poles: 2P و 4P for single- and three-phase systems
  • Adjustable current pairs: 5/15 A, 10/30 A, 15/45 A, 30/60 A, 60/90 A
  • Residual modes: Normal & Type S (time-delay for selective protection)
  • Sensitivity (IΔn): 300 mA / 500 mA
  • Breaking capacity (Icn): 3 kA
  • Rated voltage: 230/240 V و 400/415 V, 50/60 Hz
  • Digital current display; anti-tamper design; temperature-insensitive operation
  • Standards: NF C 61450, NF C 62411, IEC 61009

RCBO Circuit Breaker Technical Data — VDL01

المعلمةVDL01 (2P)VDL01 (4P)
الأعمدة2P4P
Adjustable current pairs (A)5/15, 10/30, 15/45, 30/60, 60/90
Rated voltage (Ue)230/240 V400/415 V
التردد50/60 هرتز
Residual modeNormal / Type S (time-delay)
Rated residual current (IΔn)300 mA / 500 mA
Breaking capacity (Icn)3 kA
Indication / InterfaceDigital current display; anti-tamper design
Temperature sensitivityInsensitive (per product note)
المعاييرNF C 61450; NF C 62411; IEC 61009

التطبيقات

  • Mains and feeder circuits requiring selective residual protection (Type S)
  • Commercial and public buildings with coordinated upstream devices
  • Three-phase distribution where 4P selectivity and higher IΔn are needed
  • Panels needing adjustable current pairs for field tuning
 

المعايير والامتثال

Designed in accordance with NF C 61450, NF C 62411, و IEC 61009. Check local codes for selectivity and discrimination requirements.

الأسئلة الشائعة

What does Type S mean on VDL01?

Type S is a time-delay residual function that helps achieve selectivity with downstream RCD/RCBOs, reducing nuisance trips on mains/feeder circuits.

How do the adjustable current pairs work?

You can select among 5/15, 10/30, 15/45, 30/60, and 60/90 A pairs to match the protected feeder and upstream device, using the built-in digital display to verify settings.

When should I choose 4P over 2P?

Use 4P for three-phase systems or when neutral switching and full four-pole isolation are required; 2P fits single-phase feeders.

Which IΔn should I use?

VDL01 offers 300 mA and 500 mA suited for upstream selectivity. Choose per local codes and coordination studies.

المراجعات

لا توجد مراجعات بعد.

كن أول من يقيم “VDL01 RCBO Circuit Breaker — 2P/4P Adjustable Residual Current Protection (up to 90A)”

لن يتم نشر عنوان بريدك الإلكتروني. الحقول الإلزامية مشار إليها بـ *