Automatic Transfer Switch (المنشطات الأمفيتامينية) Solutions

تأكد من continuous power supply مع reliable ATS solutions from Kuangya.
Covering Dual Power systems, MCCB Type switches, and Manual Load Isolation devices, designed for hospitals, data centers, factories, and critical facilities.

Automatic Transfer Switch Solutions

Select from Kuangya’s ATS series — DIN-rail modular, dual power, MCCB type, and load isolation transfer switches.

How to Choose Your Automatic Transfer Switch

Pick the right ATS by application level, control logic, and isolation requirement. Quick compare below.

السلسلةالاستخدام الرئيسيControl / MechanismPoles & CurrentWhen to choose
G2R-63 DIN RailResidential, commercial and solar backupElectronic automatic transfer + manual mode6–63A · 2P/4PNeed compact DIN-rail installation and rapid transfer between normal and standby power.
KGLD Dual PowerGrid ↔ Generator / Dual-source mainsElectronic controller + motorized mechanism20–1600A · 3P/4PNeed fast transfer, status I/O, and coordinated protection at main switchboard.
KGQ2 MCCB TypeCompact cabinets / C&I backupMCCB interlock, optional remote control100–1600A · 3P/4PPrefer MCCB structure with high breaking capacity in limited space.
KGLZ Manual IsolationManual changeover & visible isolationManual handle, mechanical interlock63–3150A · 3P/4PNeed simple, durable, and safe isolation for distribution or maintenance.

Hospital / Data Center Mains

Require fast & reliable transfer with monitoring and alarms.

Recommended: KGLD Dual Power ATS

C&I Backup in Compact Panels

Prefer MCCB framework with high SCC and compact size.

Recommended: KGQ2 Automatic Changeover

Distribution Isolation / Generator Manual

الحاجة visible isolation and straightforward manual operation.

Recommended: KGLZ Load Isolation

الميزات والفوائد الرئيسية

Reliable power transfer with safety, compliance, and long service life.

Wide Current Range

From 6A up to 3150A, suitable for small commercial to heavy industrial systems.

Multiple Mechanisms

Electronic, MCCB, or manual handle types available for different ATS applications.

Safety & Reliability

Mechanical interlock, visible isolation, and quick transfer ensure operator safety.

الامتثال للمعايير

Model-specific standards and conformity documents are available on request.

Easy Installation

Compact design, panel-mount options, and front access for wiring & service.

Durable Build

High-quality copper contacts, arc-resistant chambers, and long mechanical life >10,000 operations.

التطبيقات وحالات الاستخدام

Where Kuangya ATS is deployed across industries and power distribution levels.

Factories & Industrial Plants

High SCC coordination in compact panels; MCCB-type preferred.

Use KGQ2 MCCB Type

Telecom & Micro Data Rooms

Compact backup distribution with remote status I/O.

Use KGLD Dual Power

لماذا تختار كوانجيا

Reliable ATS manufacturer with strong engineering background and proven quality.

🏭

المصنع مباشرة

Own manufacturing base with strict QC and fast lead time.

📐

الدعم الهندسي

Guidance on sizing, wiring and installation for different applications.

⏱️

الخدمات اللوجستية السريعة

Short production cycle and reliable international shipping service.

⚙️

OEM / ODM

Custom branding and tailored specifications available on request.

🛡️

جودة معتمدة

Model-specific compliance and conformity documents are available on request.

Installation & Compliance Guide

General Installation Requirements

Automatic transfer switches must be installed by qualified electricians familiar with local wiring codes. Each Kuangya ATS is delivered with clear terminal markings and installation manuals. Ensure adequate clearance around the switch for cable bending radius, ventilation, and safe operation of the handle or actuator.

  • Mount ATS vertically inside switchboards or wall-mounted enclosures.
  • Provide sufficient space for incoming and outgoing cables.
  • Observe torque values on power terminals to guarantee reliable contact.
  • Maintain separation between power and control wiring to reduce interference.

Wiring & Connection Practices

بالنسبة لـ KGLD dual power ATS, connect the electronic controller to the power supply and signal I/O terminals. Remote monitoring, genset start/stop, and alarm outputs are available. For KGQ2 MCCB type, verify interlock wiring if optional motor mechanism or remote control is used. For KGLZ manual switches, only power conductors are connected, with mechanical interlock ensuring isolation.

Always check phase sequence and neutral connections. In 4-pole versions, the neutral conductor must be wired through the designated neutral terminal of the ATS. Incorrect neutral handling can lead to equipment malfunction or hazardous touch voltages.

Compliance & Standards

Kuangya ATS models are developed with reference to applicable transfer-switch standards, including IEC 60947-6-1 where applicable. Certification, conformity documents, and factory test reports vary by model and destination market; confirm the required documents before ordering.

When integrating ATS into low-voltage assemblies, verify that the overall short-circuit rating (SCCR) meets local regulations. Always coordinate ATS with upstream protection (fuses or MCCBs) to comply with IEC and NEC installation rules.

Safety Considerations

During installation and service:

  • Isolate all sources before working on ATS terminals.
  • Use appropriate PPE (insulated gloves, arc-rated clothing) according to site safety rules.
  • Do not bypass mechanical or electrical interlocks.
  • Check that control power and auxiliary contacts are correctly wired before energizing.

Follow the model manual, operating duty, and site maintenance plan. A qualified electrician should inspect terminal tightness, contact condition, interlock operation, and control wiring integrity.

Support & Documentation

Available documentation varies by model and project requirements. Documents may include:

  • Datasheets with dimensions, ratings, and connection diagrams.
  • Wiring guides for generator and dual-utility systems.
  • Certificates of conformity and compliance with IEC/CE standards.

Contact our engineering team for project-specific guidance or to request official compliance letters for tenders and EPC submissions.

الأسئلة الشائعة

Frequently asked questions about Kuangya automatic transfer switches.

What is the difference between G2R-63, KGLD, KGQ2 and KGLZ?

G2R-63 = Compact DIN-rail automatic transfer switch. KGLD = Dual power ATS with controller. KGQ2 = MCCB type automatic changeover. KGLZ = Manual isolation switch with visible disconnector.

Which current ratings are available?

G2R-63: 6–63A in 2P/4P; KGLD: 20–1600A, KGQ2: 100–1600A, and KGLZ: 63–3150A in 3P/4P.

Are Kuangya ATS compliant with international standards?

Models are designed for applicable transfer-switch standards. Certification and conformity documents vary by model and destination market; request the required documents before ordering.

Can ATS be used for both grid and generator switching?

Yes, ATS are designed for dual-source transfer (utility ↔ utility, or utility ↔ genset).

Do you provide wiring diagrams and installation support?

Yes, each product has wiring docs and we provide engineering support.

What is the transfer time of an ATS?

G2R-63 transfers in less than 50 ms; KGLD ≤200 ms; KGQ2 mechanical type is slightly longer; KGLZ manual transfer depends on the operator.

How is safety ensured during operation?

Automatic models use mechanical and/or electrical interlocking as applicable. Manual isolation models use mechanical interlocking and visible isolation. Always follow the model-specific wiring and operating instructions.

Can I request OEM or customized ATS?

Yes, Kuangya provides OEM/ODM with branding, rating, and panel customization.

What maintenance is required for ATS?

Follow the model manual and site maintenance schedule. A qualified electrician should inspect terminals, contacts, interlocks, and control wiring according to operating conditions.

Where can I buy Kuangya ATS?

Request a quotation through our website or contact an authorized distributor. Confirm the required current, voltage, poles, application, and delivery destination.