  • Circuit breaker RCCB type protection for residential, commercial, and light-industrial systems

  • 2P/4P options, rated current 16–100 A, sensitivities 30/100/300 mA, Ue 240 V (2P) / 415 V (4P)

  • IEC/EN 61008-1 compliance, high endurance, DIN-rail mounting, CE & UKCA

احصل على عرض أسعار

التصنيف:

لمحة عامة

The Kuangya VFL008 قاطع دارة كهربائية من نوع rccb disconnects the circuit when residual current exceeds the
preset threshold, preventing electric shock and fire hazards due to insulation faults. Available in both 2-pole and
4-pole versions, this circuit breaker rccb type suits single-phase and three-phase distribution boards in homes,
offices, and light-industrial facilities.

الميزات الرئيسية

  • Poles: 2 ف-2/ف-4
  • Rated current (In): 16, 25, 32, 40, 63, 80, 100 A
  • Rated sensitivity (IΔn): 30 / 100 / 100 / 300 مللي أمبير
  • Rated voltage (Ue): 240 فولت ~ ~ (2 فولت) / 415 فولت ~ (4 فولت)
  • Insulation voltage (Ui): 500 V   |   Frequency: 50/60 هرتز
  • Residual making & breaking (IΔm): 500 A (In 16–40 A); 630 A (63 A); 800 A (80 A); 1000 A (100 A)
  • Conditional short-circuit current (Inc = IΔc): 6 kA / 10 kA (with upstream SCPD coordination)
  • Impulse withstand (Uimp): 6 kV; Dielectric test: 2.5 kV (1 min)
  • Endurance: ≥20,000 mechanical / ≥2000 electrical operations
  • Terminal protection: IP20; fault current indicator
  • Ambient: −25 °C to +55 °C (daily avg ≤ 35 °C); Storage: −40 °C to +70 °C
  • Wiring: cable 25–35 mm² or pin-type busbar; top/bottom connection
  • التركيب: DIN rail EN 60715 (35 mm), fast clip
  • Standards/Approvals: IEC/EN 61008-1; CE / UKCA

البيانات الفنية

الطرازVFL008
الأعمدة2P, 4P
Rated current (In)16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated sensitivity (IΔn)30 mA, 100 mA, 300 mA
Rated voltage (Ue)2P: 240 V~; 4P: 415 V~
Insulation voltage (Ui)500 V
Rated frequency50/60 هرتز
Residual making & breaking (IΔm)500 A (In = 16–40 A); 630 A (In = 63 A); 800 A (In = 80 A); 1000 A (In = 100 A)
Conditional short-circuit (Inc = IΔc)6000 A, 10000 A
Tripping time classesInstantaneous / Short time delay (10–300 ms) / Selective S (150–500 ms)
Break time under IΔn (Normal)≤ 100 ms
Impulse withstand (Uimp)6 kV
Dielectric test voltage2.5 kV (1 min)
Pollution degree2
Electrical life≥ 2000 operations
Mechanical life≥ 2000 operations
Terminal protection degreeIP20
Ambient temperature (avg ≤ 35 °C)−25 °C to +55 °C
Storage temperature−40 °C to +70 °C
Terminal connectionCable / Pin-type busbar
Terminal size (cable)25–35 mm²; 18–3 / 18–2 AWG
Terminal size (busbar)10/16 mm²; 18–8 / 18–5 AWG
عزم دوران الشد2.5 N·m (≈ 22 in-lbs)
التركيبDIN rail EN 60715 (35 mm)
ConnectionTop and bottom
ApprovalsCE, UKCA

التطبيقات

  • Residential distribution boards (30 mA additional protection)
  • Commercial buildings requiring coordinated leakage and short-circuit protection
  • Light-industrial panels; consider short-time-delay or S-selective per coordination study