RCCB VFL007 - قاطع دارة التيار المتبقي

  • Breaker RCCB designed for 2P and 4P systems, ensuring reliable leakage current protection

  • Rated current options: 16A–100A, sensitivity: 30mA / 100mA / 300mA

  • IEC/EN 61008-1 compliance, compact DIN rail mounting, long mechanical and electrical life

احصل على عرض أسعار

التصنيف:

لمحة عامة

إن VFL007 breaker RCCB is engineered to protect people and equipment from earth leakage currents,
preventing electric shocks and fire hazards. With 2 pole and 4 pole versions, it suits both residential and
industrial installations. The device complies with IEC/EN 61008-1
and provides dependable protection in diverse applications.

الميزات الرئيسية

  • Available in 2P and 4P configurations for single-phase and three-phase systems
  • Rated current range: 16A, 25A, 32A, 40A, 63A, 80A, 100A
  • Rated residual operating current (IΔn): 30mA, 100mA, 300mA
  • Rated voltage: 2P 240V, 4P 415V
  • Short-circuit capacity up to 10kA
  • Impulse withstand voltage: 6kV
  • Terminal protection: IP20
  • Operating temperature range: −25°C to +55°C
  • Test button for quick verification
  • DIN rail mounting with compact design

البيانات الفنية

قياسيIEC/EN 61008-1
الأعمدة2P, 4P
التيار المقنن في16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Sensitivity IΔn30 مللي أمبير، 100 مللي أمبير، 300 مللي أمبير
الفولتية المقدرة Ue2P: 240V / 4P: 415V
التردد المقدر50/60Hz
Short-Circuit Capacity10 كيلو أمبير
Impulse Withstand Voltage6kV
Terminal Size (cable)25–35 mm²
Terminal Size (busbar)18–8 AWG
Terminal Protection DegreeIP20
الحياة الميكانيكية≥ 2000 operations
Electrical Life≥ 2000 operations
درجة حرارة التشغيل−25°C to +55°C
درجة حرارة التخزين−40°C to +70°C
التركيبDIN rail EN 60715 (35mm)

التطبيقات

The VFL007 breaker RCCB is suitable for multiple distribution systems where leakage protection is required:

الشهادات

  • IEC/EN 61008-1 compliance
  • CE certification
  • UKCA approval
  • توجيه RoHS

الأسئلة الشائعة

What is the purpose of the VFL007 breaker RCCB?

It disconnects the circuit when leakage current is detected, protecting against electric shocks and fire risks.

Can the VFL007 be used alone for overload protection?

No. RCCBs provide earth leakage protection only; MCBs or MCCBs must be combined for overload and short-circuit protection.

What are the available sensitivity options?

The VFL007 breaker RCCB supports 30mA, 100mA, and 300mA sensitivities for different applications.

المراجعات

لا توجد مراجعات بعد.

كن أول من يقيم “RCCB VFL007 — Residual Current Circuit Breaker”

لن يتم نشر عنوان بريدك الإلكتروني. الحقول الإلزامية مشار إليها بـ *