قاطع الدائرة الكهربائية VFL005 من النوع RCCB - 2P و4P حماية التيار المتبقي

  • Circuit breaker RCCB type for reliable residual current protection in residential and industrial systems

  • Available in 2 pole & 4 pole versions, rated current options 16A to 100A, sensitivity from 30mA to 300mA

  • Compliant with IEC/EN 61008-1, featuring high short-circuit withstand capacity and compact installation

احصل على عرض أسعار

التصنيف:

لمحة عامة

إن VFL005 circuit breaker RCCB type provides effective protection against leakage current, electric shocks,
and fire hazards caused by ground faults. Designed with 2P and 4P configurations, it ensures reliable safety in both
residential and commercial installations. The unit complies with IEC/EN 61008-1 standards.

الميزات الرئيسية

  • 2P and 4P residual current circuit breaker with rated currents from 16A to 100A
  • Sensitivity options: 30mA, 100mA, 300mA for flexible protection levels
  • Rated voltage: 2P up to 240V, 4P up to 415V
  • Short-circuit withstand capacity up to 10kA
  • High surge immunity up to 6kV
  • Test button for functional verification
  • Terminal protection degree: IP20
  • Operating temperature: −25°C to +55°C

البيانات الفنية

قياسيIEC/EN 61008-1
الأعمدة2P, 4P
التيار المقنن في16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Sensitivity IΔn30 مللي أمبير، 100 مللي أمبير، 300 مللي أمبير
الفولتية المقدرة Ue2P: 240V / 4P: 415V
التردد المقدر50/60Hz
Short-Circuit Capacity10 كيلو أمبير
Impulse Withstand Voltage6kV
Terminal Size for Cable25–35 mm²
Terminal ProtectionIP20
الحياة الميكانيكية≥ 2000 operations
Electrical Life≥ 2000 operations
التركيبDIN rail EN 60715 (35mm)

التطبيقات

The VFL005 circuit breaker RCCB type is suitable for residential, commercial, and industrial distribution systems.
Common applications include:

الشهادات

  • IEC/EN 61008-1 compliance
  • CE certified
  • UKCA compliant
  • توجيه RoHS

الأسئلة الشائعة

What is the difference between a 2P and 4P RCCB?

2P RCCBs are used in single-phase systems, while 4P RCCBs are designed for three-phase systems. The choice depends on the type of installation.

Does the VFL005 circuit breaker RCCB type protect against overload?

No, RCCBs are intended for residual current (earth leakage) protection. Overcurrent and short-circuit protection require an MCB or MCCB in combination.

What are the available rated currents for VFL005?

The VFL005 supports 16A, 25A, 32A, 40A, 63A, 80A, and 100A configurations.

المراجعات

لا توجد مراجعات بعد.

كن أول من يقيم “VFL005 Circuit Breaker RCCB Type – 2P & 4P Residual Current Protection”

لن يتم نشر عنوان بريدك الإلكتروني. الحقول الإلزامية مشار إليها بـ *