VRL01 / VRL02 / VRL03 RCBO — Single-Pole + Neutral (1P+N) 6–50A

  • rcbo single pole (1P+N) modular RCBO for single-phase branches, In 6–50A, tripping curves B/C.

  • Type AC / Type A, sensitivities IΔn 10 / 30 / 100 / 300 mA; Icn 6 kA / 10 kA @ 240 V, 50/60 Hz.

  • Certified SEMKO / UKCA / CE; standard IEC/EN 61009-1; front test button, DIN-rail mounting.

Получить предложение

Категория:

rcbo single pole VRL01 / VRL02 / VRL03 integrates residual-current and overcurrent protection in a compact 1P+N format, rated 6–50 A for 240 V, 50/60 Hz systems with Type AC/A and multiple IΔn options.

Обзор

The VRL01 / VRL02 / VRL03 family is designed for single-phase distribution branches where
reliable residual-current protection and coordinated overcurrent performance are required.
Each variant shares the same 1P+N footprint and broad current range up to 50 A, with
selectable tripping curves (B/C), multiple residual sensitivities, and high breaking
capacity options (6/10 kA) to match fault levels on 240 V systems.

Основные характеристики

  • Form factor: 1P+N (single-pole + neutral)
  • Rated current (In): 6–50 A (typical steps: 6/10/16/20/25/32/40/50 A)
  • Rated voltage (Ue): AC 240 V, 50/60 Hz
  • Residual current type: Type AC / Type A
  • Sensitivities (IΔn): 10 / 30 / 100 / 300 мА
  • MCB tripping curves: B (3–5×In) и C (5–10×In)
  • Breaking capacity (Icn): 6 kA / 10 kA @ 240 V
  • Front test button (T); DIN-rail mounting; front wiring
  • Compliance & certification: IEC/EN 61009-1; SEMKO, UKCA, CE

RCBO Single Pole Technical Data — VRL01 / VRL02 / VRL03

ПараметрVRL01VRL02VRL03
Поляки1P+N (single-pole + neutral)
Rated current (In)6–50 A6–50 A6–50 A
Rated voltage (Ue)AC 240 VAC 240 VAC 240 V
Частота50/60 Hz
Residual current typeType AC / Type A
Rated residual current (IΔn)10 / 30 / 100 / 300 мА
MCB tripping curveB: 3–5 × In; C: 5–10 × In
Breaking capacity (Icn)6 kA / 10 kA @ 240 V6 kA / 10 kA @ 240 V6 kA / 10 kA @ 240 V
УстановкаDIN-rail; front wiring; test button (T)
Recommended useResidential & commercial branches (lighting / sockets) within 1P+N and ≤50 A
СтандартыIEC/EN 61009-1
СертификатыSEMKO, UKCA, CE

Приложения

  • Apartments & houses: lighting/socket circuits up to 50 A
  • Commercial offices & retail: small-to-medium branch protection
  • Public facilities: classrooms, admin areas, auxiliary circuits
 

Standards & Compliance

Conforms to IEC/EN 61009-1 with certifications SEMKO, UKCA, CE.
Coordinate with upstream protective devices; follow local codes for selectivity and fault levels.

ЧАСТО ЗАДАВАЕМЫЕ ВОПРОСЫ

Do VRL01, VRL02 and VRL03 differ in core protection features?

All three share the same 1P+N format, 6–50 A range, Type AC/A residual options and B/C curves. They are part of the same platform with high breaking-capacity options (6/10 kA) for 240 V systems.

Which sensitivity (IΔn) should be used for sockets and lighting?

30 mA is most common for socket/lighting circuits. 10 mA is for higher touch-safety; 100/300 mA may be used per coordination and local code requirements.

How to choose between curve B and curve C?

Use curve B (3–5×In) for resistive/lightly inductive loads; use curve C (5–10×In) for circuits with higher inrush such as motors or transformers.

Отзывы

Отзывов пока нет.

Будьте первым, кто оставил отзыв на “VRL01 / VRL02 / VRL03 RCBO — Single-Pole + Neutral (1P+N) 6–50A”

Ваш адрес email не будет опубликован. Обязательные поля помечены *