DC MCCB | 250V 250A Moulded Case Circuit Breaker

KUANGYA DC Circuit Protection

DC MCCB for Battery, ESS and Low-Voltage PV Circuits

MCCB-250DC is a compact 1-pole moulded case circuit breaker rated 250A at 250V DC, with a nameplate Icu of 25kA. Use this page to review confirmed ratings, selection checks and project information before requesting a quotation.

KUANGYA MCCB-250DC 1P 250A 250V DC moulded case circuit breaker
250 В ПОСТОЯННОГО ТОКАНоминальное рабочее напряжение
250AНоминальный ток
25 кАUltimate breaking capacity (Icu)
1 PoleCompact DC format

What Is a DC MCCB?

A DC moulded case circuit breaker provides switching and overcurrent protection for a correctly engineered direct-current circuit. Compared with a miniature circuit breaker, an MCCB is generally selected where higher current, higher fault-duty or more robust panel integration is required. DC arc interruption is demanding, so voltage, polarity, pole arrangement and prospective short-circuit current must be verified for the exact application.

MCCB-250DC Confirmed Specifications

ПараметрConfirmed valueSelection meaning
Product typeDC moulded case circuit breakerFor suitably engineered DC circuits
МодельMCCB-250DCKUANGYA product designation
Количество столбов1PDoes not automatically isolate every live conductor
Номинальный ток (В)250ACheck conductor ampacity, enclosure temperature and derating
Номинальное рабочее напряжение (Ue)250 В ПОСТОЯННОГО ТОКАMaximum operating voltage must remain within the device rating
Ultimate breaking capacity (Icu)25 кАAvailable fault current must be assessed at the installation point
Service breaking capacity (Ics)75% of IcuConfirm project duty and coordination requirements

Values above are based on the product nameplate and current product page. Confirm the offered model, documentation and applicable certification scope before ordering.

Типовые применения

Battery & ESS

DC distribution and protection in battery banks and energy-storage cabinets after calculation of maximum voltage and fault current.

Low-Voltage Solar PV

PV circuits whose maximum operating and open-circuit voltage remain within the device rating under the lowest expected temperature.

Industrial DC Distribution

Control power, charging equipment and DC panels requiring a 250A moulded-case protective device.

Information Needed for MCCB Selection

Send these values with your enquiry so our team can check the model more efficiently:

  • Maximum continuous DC system voltage
  • Normal load current and conductor size
  • Calculated prospective short-circuit current
  • Battery, ESS, PV or industrial application
  • Required poles and isolation arrangement
  • Ambient temperature and enclosure conditions
  • Upstream/downstream protective devices
  • Quantity, destination country and OEM needs

DC MCCB vs DC MCB

Selection pointDC MCCBDC MCB
Typical useHigher-current feeders and panel protectionLower-current branch circuits
Form factorMoulded-case, panel mountedCompact modular/DIN-rail format
Selection priorityCurrent, voltage, fault duty, poles and coordinationCurrent, voltage, trip curve, fault duty and poles

This comparison is general. Final device selection must be based on the exact manufacturer data and project design.

Часто задаваемые вопросы

Can a 250V DC MCCB be used on a higher-voltage system?

No. The maximum operating voltage, including credible system conditions, must not exceed the device’s stated DC rating. Use a model and pole arrangement specifically documented for the higher voltage.

Is a 1P MCCB a complete DC isolator?

Not automatically. The required number of poles and isolation arrangement depend on the earthing system, live conductors, equipment instructions and local rules.

Is 25kA always sufficient?

Only when the calculated prospective short-circuit current at the installation point, together with the required coordination and duty, is within the device’s documented capability.

What should I send for an accurate quotation?

Provide system voltage, load current, calculated fault current, application, pole requirement, quantity, destination country and any OEM or certification requirements.

Related Protection Products

Need Model Confirmation or OEM Pricing?

Tell KUANGYA your electrical parameters and purchasing requirements. We will help confirm the suitable model before quotation.