RCCB VKL001 - автоматический выключатель остаточного тока

  • The Kuangya VKL001 однофазное устройство rccb device disconnects circuits upon residual current, preventing electric shock and fire hazards.

  • 2P / 4P options; In 16–100 A; IΔn 10/30/100/300 mA; Ue 240 V (2P) / 415 V (4P); Inc = IΔc up to 10 kA; Uimp 6 kV.

  • Compliant with IEC/EN 61008-1; approvals: SEMKO, UKCA, CE.

Получить предложение

Категория:

Обзор

The VKL001 однофазное устройство rccb (also available for three-phase boards as 4P) detects earth-leakage
currents and trips before harm occurs, providing protection for people and installations. It is widely applied in
housing, the tertiary sector, and industry. Selection covers rated currents from 16 A to 100 A and residual
sensitivities from 10 mA to 300 mA.

Detection classes & selection

  • AC class — trips for slowly increasing sinusoidal AC residual currents, whether applied slowly or suddenly.
  • A class — all AC features plus tripping for pulsating DC residual currents, whether applied suddenly or increasing slowly.
  • High-immunity variants (Si/G/KV) — filters against spurious tripping caused by harmonics and transient surges; stable under 8/20 μs surge of 3000 A (per datasheet note).

Tripping sensitivity & time

  • 10 mA — precision instrument leakage protection and bathroom use (available on 2P/4P 16–40 A).
  • 30 мА — additional protection against direct contact.
  • 100 мА — coordinated with the earthing system for indirect contact protection.
  • 300 мА — protection against indirect contacts and fire hazards.
  • Instantaneous — tripping without intentional delay; break time under IΔn (Normal) ≤ 100 ms.
  • Короткая временная задержка (Si, G, KV) — ensures any tripping at least 10 ms (10–300 ms range).
  • Selective (S) — 150–500 ms, ensures discrimination with a downstream non-selective RCD.

Key features

  • Configurations: 2P / 4P; top or bottom supply; any mounting position.
  • Rated current In: 16, 25, 32, 40, 63, 80, 100 A.
  • Rated sensitivity IΔn: 10 мА (2P/4P 16-40 A), 30 мА, 100 мА, 300 мА.
  • Rated voltage Ue: 2P: 240 V~; 4P: 415 V~. Ui: 500 V. Частота: 50/60 Гц.
  • Остаточное создание и разрушение (IΔm): 500 A (In 16–40 A); 630 A (63 A); 800 A (80 A); 1000 A (100 A).
  • Условное короткое замыкание (Inc = IΔc): 6000 A or 10000 A (with upstream SCPD coordination).
  • Выдерживаемый импульс (Uimp): 6 кВ; Диэлектрическое испытание: 2.5 kV (1 min at power frequency).
  • Выносливость: ≥ 20,000 mechanical operations / ≥ 2000 electrical operations.
  • Степень защиты клемм: IP20; Fault current indicator: Yes.
  • Ambient: −25 °C … +55 °C (daily avg ≤ 35 °C); Storage: −40 °C … +70 °C.
  • Терминалы: cable / pin-type busbar; sizes (cable): 25–35 mm²; 18–3 / 18–2 AWG; sizes (busbar): 10/16 mm²; 18–8 / 18–5 AWG.
  • Момент затяжки: 2.5 N·m (≈ 22 in-lbs).
  • Крепление: DIN rail EN 60715 (35 mm), fast clip device; connection from top and bottom.
  • Standards & approvals: IEC/EN 61008-1; SEMKO, UKCA, CE.

Technical Data (full table)

СтандартIEC/EN 61008-1
Модель №.VKL001
Поляки2P, 4P
Номинальный ток (В)16A, 25A, 32A, 40A, 63A, 80A, 100A
Номинальная чувствительность (IΔn)10 mA (2P/4P 16–40 A), 30 mA, 100 mA, 300 mA
Номинальное напряжение (Ue)2P: 240 V~; 4P: 415 V~
Напряжение изоляции (Ui)500 V
Rated frequency (fn)50/60 Гц
Rated residual making & breaking (IΔm)500 A (В = 16-40 A); 630 A (В = 63 A); 800 A (В = 80 A); 1000 A (В = 100 A)
Условный ток короткого замыкания (Inc = IΔc)6000 A; 10000 A
Тип (измеряемая форма волны)AC, A
Tripping time (Instantaneous)Break time under IΔn ≤ 100 ms
Tripping time (Short time delay)10–300 ms (Si, G, KV types)
Tripping time (Selective S)150–500 ms
Выдерживаемый импульс (Uimp)6 кВ
Испытательное напряжение диэлектрика2,5 кВ (1 мин)
Степень загрязнения2
Срок службы электрооборудования≥ 2000 операций
Механический срок службы≥ 20,000 operations
Индикатор тока неисправностиДа
Степень защиты клеммIP20
Температура окружающей среды−25 °C to +55 °C (daily avg ≤ 35 °C)
Температура храненияот -40 °C до +70 °C
Тип клеммного соединенияКабель / Штыревая шина
Размер клеммы (кабель)25-35 мм²; 18-3 / 18-2 AWG
Размер клемм (шина)10/16 мм²; 18-8 / 18-5 AWG
Момент затяжки2,5 Н-м (≈ 22 дюйма-фунта)
МонтажDIN rail EN 60715 (35 mm), fast clip
СоединениеСверху и снизу
ОдобренияСЕМКО, УККА, КЭ

Приложения

  • Single-phase boards requiring an однофазное устройство rccb device at 240 V~ (2P).
  • Three-phase distribution at 415 V~ (4P) with coordination for 6/10 kA conditional short-circuit.
  • Loads with electronics and frequent transients — use high-immunity variants (Si/G/KV) to reduce nuisance trips.

rccb single phase VKL001 Kuangya 2P/4P 16–100A 10/30/100/300 mA