RCCB VKL005 - автоматический выключатель остаточного тока

  • 4 полюса rccb for reliable residual-current protection in three-phase systems; 2P version for single-phase

  • In 16–100 A; IΔn 10/30/100/300 mA; Ue 240 V (2P) / 415 V (4P); Inc = IΔc up to 10 kA; Uimp 6 kV

  • IEC/EN 61008-1 compliance, DIN-rail EN 60715 mounting, IP20 terminals

Получить предложение

Категория:

Обзор

Kuangya VKL005 4 полюса rccb (also available in 2P) detects earth-leakage current and disconnects
the circuit to protect people and installations against electric shock and fire hazards caused by insulation faults.
It is suitable for residential, commercial and light-industrial distribution boards.

Основные характеристики

  • Poles: 2P / 4P
  • Rated current (In): 16, 25, 32, 40, 63, 80, 100 A
  • Rated sensitivity (IΔn): 10 / 30 / 100 / 300 мА
  • Rated voltage (Ue): 2P: 240 V~; 4P: 415 V~
  • Insulation voltage (Ui): 500 V; Frequency: 50/60 Hz
  • Residual making & breaking (IΔm):
    500 A (In = 16–40 A); 630 A (63 A); 800 A (80 A); 1000 A (100 A)
  • Conditional short-circuit (Inc = IΔc): 6 kA / 10 kA (with upstream SCPD)
  • Impulse withstand (Uimp): 6 kV; Dielectric test: 2.5 kV (1 min)
  • Endurance: ≥20,000 mechanical / ≥2000 electrical operations
  • Terminal protection: IP20; Tightening torque: 2.5 N·m (≈22 in-lbs)
  • Terminals & sizes: cable 25–35 mm²; pin-type busbar 10/16 mm²
  • Mounting & wiring: DIN rail EN 60715 (35 mm); top/bottom connection

Technical Data

МодельVKL005
Поляки2P, 4P
Rated current (In)16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated sensitivity (IΔn)10 mA, 30 mA, 100 mA, 300 mA
Rated voltage (Ue)2P: 240 V~; 4P: 415 V~
Insulation voltage (Ui)500 V
Rated frequency50/60 Hz
Residual making & breaking (IΔm)500 A (In = 16–40 A); 630 A (In = 63 A); 800 A (In = 80 A); 1000 A (In = 100 A)
Conditional short-circuit (Inc = IΔc)6000 A, 10000 A
Impulse withstand (Uimp)6 kV
Dielectric test2.5 kV (1 min, power frequency)
Electrical life≥2000 operations
Mechanical life≥20,000 operations
Terminal protection degreeIP20
Tightening torque2.5 N·m (≈22 in-lbs)
Terminal size (cable)25–35 mm²
Terminal size (busbar)10/16 mm²
МонтажDIN rail EN 60715 (35 mm)
ConnectionTop and bottom

Приложения

  • Three-phase panels using a 4 полюса rccb for residual-current protection
  • Single-phase boards with 2P version (30 mA for additional personal protection)
  • Commercial and light-industrial distributions coordinated with upstream SCPD (6/10 kA)

4 pole rccb VKL005 Kuangya 2P/4P 16–100A 10/30/100/300 mA

Отзывы

Отзывов пока нет.

Будьте первым, кто оставил отзыв на “RCCB VKL005 — Residual Current Circuit Breaker”

Ваш адрес email не будет опубликован. Обязательные поля помечены *