VDL006 RCBO - однополюсный + нейтраль (1P+N) 6-40A

  • rcbo однополюсный (1P+N) compact RCBO for residential & commercial branches, In 6–40A.

  • Тип AC / Тип A, чувствительность IΔn 10 / 30 / 100 / 300 мА; Icn 3 / 4.5 / 6 kA @ 240 V.

  • Сертифицированный SEMKO / UKCA / CE / SAA; DIN-rail mounting, front test button.

Получить предложение

Категория:

rcbo однополюсный VDL006 integrates residual-current and overcurrent protection in a compact 1P+N form factor, covering 6–40 A with Type AC/A and multiple sensitivities for residential and commercial circuits.

Обзор

VDL006 is a single-pole + neutral (1P+N) modular RCBO designed for single-phase
distribution branches where space efficiency and coordinated protection are required.
It supports Type AC and Type A residual protections with selectable sensitivities
(10 / 30 / 100 / 300 mA) and offers multiple breaking-capacity options (3 / 4.5 / 6 kA)
to match different fault-level environments on 240 V, 50/60 Hz systems.

Основные характеристики

  • Форм-фактор: 1P+N, compact single-module width
  • Номинальный ток (В): 6–40 A (typical steps: 6/10/16/20/25/32/40 A)
  • Тип остаточного тока: Тип AC / Тип A
  • Чувствительность (IΔn): 10 / 30 / 100 / 300 мА
  • Разрывная способность (Icn): 3 / 4.5 / 6 kA @ 240 V
  • Номинальное напряжение: AC 240 В, 50/60 Гц
  • Передняя кнопка тестирования (T) для обычной проверки остаточных функций
  • DIN-rail mounting; front wiring; compact installation depth

RCBO Single Pole Technical Data — VDL006

ПараметрVDL006
Поляки1P+N (однополюсный + нейтральный)
Номинальный ток (В)6–40 A
Номинальное напряжение (Ue)AC 240 В
Частота50/60 Гц
Тип остаточного токаТип AC / Тип A
Номинальный остаточный ток (IΔn)10 / 30 / 100 / 300 мА
Разрывная способность (Icn)3 / 4.5 / 6 kA @ 240 V
УстановкаDIN-рейка; проводка спереди; контрольная кнопка (T)
Рекомендуемое использованиеResidential & commercial branch circuits (lighting / sockets)

Приложения

  • Apartment & house distribution boards (lighting / socket circuits)
  • Commercial offices & retail small-load protection
  • Public buildings’ auxiliary branches within 1P+N and ≤40 A
 

Standards & Certifications

Compliance: IEC/EN 61009-1. Certifications: СЕМКО, УККА, КЭ, САА.
Always verify coordination and local code requirements for selectivity and fault levels.

ЧАСТО ЗАДАВАЕМЫЕ ВОПРОСЫ

What does VDL006 cover compared to higher-end multi-pole models?

VDL006 targets 1P+N single-phase branches up to 40 A on 240 V systems, with Type AC/A residual protection and multiple IΔn and Icn options. For three-phase or EV/Type B scenarios, choose other series accordingly.

Which sensitivity (IΔn) is typical for sockets?

30 mA is commonly used for socket/lighting circuits; 10 mA for higher touch-safety requirements; 100/300 mA per coordination needs and local codes.

Does VDL006 support rcbo single pole installation space saving?

Yes. The compact 1P+N design helps save rail width while providing full residual and overcurrent protection.

Отзывы

Отзывов пока нет.

Будьте первым, кто оставил отзыв на “VDL006 RCBO — Single-Pole + Neutral (1P+N) 6–40A”