Automatic Transfer Switch (ATS) Solutions

Ensure continuous power supply com reliable ATS solutions from Kuangya.
Covering Dual Power systems, MCCB Type switches, and Manual Load Isolation devices, designed for hospitals, data centers, factories, and critical facilities.

Automatic Transfer Switch Solutions

Select from Kuangya’s ATS series — dual power, MCCB type, and load isolation transfer switches.

How to Choose Your Automatic Transfer Switch

Pick the right ATS by application level, control logic, and isolation requirement. Quick compare below.

SérieMain UseControl / MechanismPoles & CurrentWhen to choose
KGLD Dual PowerGrid ↔ Generator / Dual-source mainsElectronic controller + motorized mechanism20–1600A · 3P/4PNeed fast transfer, status I/O, and coordinated protection at main switchboard.
KGQ2 MCCB TypeCompact cabinets / C&I backupMCCB interlock, optional remote control100–1600A · 3P/4PPrefer MCCB structure with high breaking capacity in limited space.
KGLZ Manual IsolationManual changeover & visible isolationManual handle, mechanical interlock63–3150A · 3P/4PNeed simple, durable, and safe isolation for distribution or maintenance.

Hospital / Data Center Mains

Require fast & reliable transfer with monitoring and alarms.

Recomendado: KGLD Dual Power ATS

Distribution Isolation / Generator Manual

Need visible isolation and straightforward manual operation.

Recomendado: KGLZ Load Isolation

Principais recursos e benefícios

Reliable power transfer with safety, compliance, and long service life.

Wide Current Range

From 20A up to 3150A, suitable for small commercial to heavy industrial systems.

Multiple Mechanisms

Electronic, MCCB, or manual handle types available for different ATS applications.

Safety & Reliability

Mechanical interlock, visible isolation, and quick transfer ensure operator safety.

Standards Compliance

Designed according to IEC 60947-6-1 & international approvals.

Easy Installation

Compact design, panel-mount options, and front access for wiring & service.

Durable Build

High-quality copper contacts, arc-resistant chambers, and long mechanical life >10,000 operations.

Aplicativos e casos de uso

Where Kuangya ATS is deployed across industries and power distribution levels.

Factories & Industrial Plants

High SCC coordination in compact panels; MCCB-type preferred.

Use KGQ2 MCCB Type

Telecom & Micro Data Rooms

Compact backup distribution with remote status I/O.

Use KGLD Dual Power

Por que escolher Kuangya?

Reliable ATS manufacturer with strong engineering background and proven quality.

🏭

Direto da fábrica

Own manufacturing base with strict QC and fast lead time.

📐

Engineering Support

Guidance on sizing, wiring and installation for different applications.

⏱️

Logística rápida

Short production cycle and reliable international shipping service.

⚙️

OEM / ODM

Custom branding and tailored specifications available on request.

🛡️

Qualidade certificada

Products designed under IEC standards with CE & RoHS compliance.

Installation & Compliance Guide

General Installation Requirements

Automatic transfer switches must be installed by qualified electricians familiar with local wiring codes. Each Kuangya ATS is delivered with clear terminal markings and installation manuals. Ensure adequate clearance around the switch for cable bending radius, ventilation, and safe operation of the handle or actuator.

  • Mount ATS vertically inside switchboards or wall-mounted enclosures.
  • Provide sufficient space for incoming and outgoing cables.
  • Observe torque values on power terminals to guarantee reliable contact.
  • Maintain separation between power and control wiring to reduce interference.

Wiring & Connection Practices

Para KGLD dual power ATS, connect the electronic controller to the power supply and signal I/O terminals. Remote monitoring, genset start/stop, and alarm outputs are available. For KGQ2 MCCB type, verify interlock wiring if optional motor mechanism or remote control is used. For KGLZ manual switches, only power conductors are connected, with mechanical interlock ensuring isolation.

Always check phase sequence and neutral connections. In 4-pole versions, the neutral conductor must be wired through the designated neutral terminal of the ATS. Incorrect neutral handling can lead to equipment malfunction or hazardous touch voltages.

Compliance & Standards

Kuangya ATS are designed according to IEC 60947-6-1, covering automatic and manual transfer switches. Products carry CE and RoHS conformity, and can be supplied with factory test reports. For large projects, witness testing and additional certificates (TÜV, CB scheme) can be arranged upon request.

When integrating ATS into low-voltage assemblies, verify that the overall short-circuit rating (SCCR) meets local regulations. Always coordinate ATS with upstream protection (fuses or MCCBs) to comply with IEC and NEC installation rules.

Considerações sobre segurança

During installation and service:

  • Isolate all sources before working on ATS terminals.
  • Use appropriate PPE (insulated gloves, arc-rated clothing) according to site safety rules.
  • Do not bypass mechanical or electrical interlocks.
  • Check that control power and auxiliary contacts are correctly wired before energizing.

Periodic inspection is recommended every 6–12 months depending on load cycles. Inspect contact wear, interlock operation, and control wiring integrity.

Support & Documentation

Each Kuangya ATS is shipped with a printed manual and QR code for online resources. Additional documents include:

  • Datasheets with dimensions, ratings, and connection diagrams.
  • Wiring guides for generator and dual-utility systems.
  • Certificates of conformity and compliance with IEC/CE standards.

Contact our engineering team for project-specific guidance or to request official compliance letters for tenders and EPC submissions.

PERGUNTAS FREQUENTES

Frequently asked questions about Kuangya automatic transfer switches.

What is the difference between KGLD, KGQ2 and KGLZ?

KGLD = Dual power ATS with controller. KGQ2 = MCCB type automatic changeover. KGLZ = Manual isolation switch with visible disconnector.

Which current ratings are available?

KGLD: 20–1600A, KGQ2: 100–1600A, KGLZ: 63–3150A. All in 3P/4P versions.

Are Kuangya ATS compliant with international standards?

Yes, designed to IEC 60947-6-1 with CE & RoHS conformity.

Can ATS be used for both grid and generator switching?

Yes, ATS are designed for dual-source transfer (utility ↔ utility, or utility ↔ genset).

Do you provide wiring diagrams and installation support?

Yes, each product has wiring docs and we provide engineering support.

What is the transfer time of an ATS?

KGLD ≤200 ms, KGQ2 mechanical type slightly longer, KGLZ manual depends on operator.

How is safety ensured during operation?

All ATS have mechanical/electrical interlocks to prevent simultaneous ON. Manual type ensures visible isolation.

Can I request OEM or customized ATS?

Yes, Kuangya provides OEM/ODM with branding, rating, and panel customization.

What maintenance is required for ATS?

Check contacts, terminals, and interlock every 6–12 months. Replace worn modules if necessary.

Where can I buy Kuangya ATS?

Purchase directly via our website, authorized distributors, or request a quote online.