Ensure continuous power supply com reliable ATS solutions from Kuangya.
Covering Dual Power systems, MCCB Type switches, and
Manual Load Isolation devices, designed for hospitals, data centers, factories, and critical facilities.
Select from Kuangya’s ATS series — dual power, MCCB type, and load isolation transfer switches.
Pick the right ATS by application level, control logic, and isolation requirement. Quick compare below.
Série | Main Use | Control / Mechanism | Poles & Current | When to choose |
---|---|---|---|---|
KGLD Dual Power | Grid ↔ Generator / Dual-source mains | Electronic controller + motorized mechanism | 20–1600A · 3P/4P | Need fast transfer, status I/O, and coordinated protection at main switchboard. |
KGQ2 MCCB Type | Compact cabinets / C&I backup | MCCB interlock, optional remote control | 100–1600A · 3P/4P | Prefer MCCB structure with high breaking capacity in limited space. |
KGLZ Manual Isolation | Manual changeover & visible isolation | Manual handle, mechanical interlock | 63–3150A · 3P/4P | Need simple, durable, and safe isolation for distribution or maintenance. |
Require fast & reliable transfer with monitoring and alarms.
Recomendado: KGLD Dual Power ATS
Prefer MCCB framework with high SCC and compact size.
Recomendado: KGQ2 Automatic Changeover
Need visible isolation and straightforward manual operation.
Recomendado: KGLZ Load Isolation
Reliable power transfer with safety, compliance, and long service life.
From 20A up to 3150A, suitable for small commercial to heavy industrial systems.
Electronic, MCCB, or manual handle types available for different ATS applications.
Mechanical interlock, visible isolation, and quick transfer ensure operator safety.
Designed according to IEC 60947-6-1 & international approvals.
Compact design, panel-mount options, and front access for wiring & service.
High-quality copper contacts, arc-resistant chambers, and long mechanical life >10,000 operations.
Where Kuangya ATS is deployed across industries and power distribution levels.
Main switchboards needing fast transfer and alarm/monitoring.
Use KGLD Dual Power ATSReliable backup for elevators, HVAC, lighting, and critical loads.
Use KGQ2 Automatic ChangeoverHigh SCC coordination in compact panels; MCCB-type preferred.
Use KGQ2 MCCB TypeSimple, durable, visible isolation for generator rooms.
Use KGLZ Load IsolationReliable ATS manufacturer with strong engineering background and proven quality.
Own manufacturing base with strict QC and fast lead time.
Guidance on sizing, wiring and installation for different applications.
Short production cycle and reliable international shipping service.
Custom branding and tailored specifications available on request.
Products designed under IEC standards with CE & RoHS compliance.
Automatic transfer switches must be installed by qualified electricians familiar with local wiring codes. Each Kuangya ATS is delivered with clear terminal markings and installation manuals. Ensure adequate clearance around the switch for cable bending radius, ventilation, and safe operation of the handle or actuator.
Para KGLD dual power ATS, connect the electronic controller to the power supply and signal I/O terminals. Remote monitoring, genset start/stop, and alarm outputs are available. For KGQ2 MCCB type, verify interlock wiring if optional motor mechanism or remote control is used. For KGLZ manual switches, only power conductors are connected, with mechanical interlock ensuring isolation.
Always check phase sequence and neutral connections. In 4-pole versions, the neutral conductor must be wired through the designated neutral terminal of the ATS. Incorrect neutral handling can lead to equipment malfunction or hazardous touch voltages.
Kuangya ATS are designed according to IEC 60947-6-1, covering automatic and manual transfer switches. Products carry CE and RoHS conformity, and can be supplied with factory test reports. For large projects, witness testing and additional certificates (TÜV, CB scheme) can be arranged upon request.
When integrating ATS into low-voltage assemblies, verify that the overall short-circuit rating (SCCR) meets local regulations. Always coordinate ATS with upstream protection (fuses or MCCBs) to comply with IEC and NEC installation rules.
During installation and service:
Periodic inspection is recommended every 6–12 months depending on load cycles. Inspect contact wear, interlock operation, and control wiring integrity.
Each Kuangya ATS is shipped with a printed manual and QR code for online resources. Additional documents include:
Contact our engineering team for project-specific guidance or to request official compliance letters for tenders and EPC submissions.
Frequently asked questions about Kuangya automatic transfer switches.
KGLD = Dual power ATS with controller. KGQ2 = MCCB type automatic changeover. KGLZ = Manual isolation switch with visible disconnector.
KGLD: 20–1600A, KGQ2: 100–1600A, KGLZ: 63–3150A. All in 3P/4P versions.
Yes, designed to IEC 60947-6-1 with CE & RoHS conformity.
Yes, ATS are designed for dual-source transfer (utility ↔ utility, or utility ↔ genset).
Yes, each product has wiring docs and we provide engineering support.
KGLD ≤200 ms, KGQ2 mechanical type slightly longer, KGLZ manual depends on operator.
All ATS have mechanical/electrical interlocks to prevent simultaneous ON. Manual type ensures visible isolation.
Yes, Kuangya provides OEM/ODM with branding, rating, and panel customization.
Check contacts, terminals, and interlock every 6–12 months. Replace worn modules if necessary.
Purchase directly via our website, authorized distributors, or request a quote online.