Arc-fault detection device (AFDD) with integrated overcurrent and residual current protection.
Rated current range: 6A–40A잔류 전류 유형 A, tripping curve B/C.
다음 사항을 준수합니다. EN62606 & EN61009-1, short-circuit capacity 6kA.
그리고 AFDD-1 Arc Fault Detection Device integrates 아크 결함 감지(AFDD),
overcurrent protection (MCB) 및 residual current protection (RCCB, Type A) in one compact 1P+N module.
It complies with EN62606 및 EN61009-1, providing early detection of series/parallel arc faults
and fast disconnection to reduce fire risks in residential, commercial and industrial installations.
| 시리즈 | AFDD |
|---|---|
| 모델 | AFDD-1 |
| 폴 | 1P+N (1 Module) |
| Rated current (AC) | 6A, 10A, 13A, 16A, 20A, 25A, 32A, 40A |
| Residual current type | 유형 A |
| Rated residual current IΔn | 10 mA, 30 mA |
| Min./Max. test circuit voltage | 196 V / 253 V |
| Tripping characteristic | B, C |
| Operating frequency | 50Hz |
| Impulse withstand voltage (Uimp) | 4 kV |
| Rated voltage (AC) | 240 V |
| Rated short-circuit current (Icn) | 6 kA |
| Surge current strength | 0.25 kA |
| Max. total switching capacity | 6 kA |
| Rated insulation voltage | 250 V |
| Heat loss per pole | 3 W |
| Short-circuit backup fuse (SCPD) | 100 A (gG) |
| Overvoltage class | III |
| Terminals | Screw-type, top & bottom (load circuit) |
| Neutral conductor position | Left / Right |
| Max. connection cable length | 70 m (DB to outer socket) |
| Clamping area | 1–25 mm² |
| Tightening torque | 2.0–2.4 Nm |
| Mechanical endurance | ≥ 20,000 cycles |
| Electrical endurance | ≥ 4,000 cycles |
| Storage / Operating temperature | -35℃…+60℃ / -25℃…+40℃ |
| Housing type / material | Distribution board housing / Thermoplastic |
| 마운팅 | DIN rail (35 mm) |
| Protection class | IP20 (installed: IP40) |
| 표준 | EN62606, EN61009-1 |
| Power limitation category | 3 |
| Pollution degree (EN60664) | 2 |
| 인증 | UKCA, CE |
Fire protection for final circuits up to 40 A in residential, commercial and public buildings
(bedrooms, offices, hospitals, schools). Suitable for TN-S 및 TN-C-S networks.
Not suitable for TN-C systems or circuits with smooth DC residual currents not equal to 50 Hz.
AFDD detects series/parallel arc faults to prevent fires; RCCB trips on residual (leakage) current. AFDD-1 integrates AFDD + MCB + RCCB in one device.
No. AFDD-1 is intended for TN-S and TN-C-S networks.
Type A: sinusoidal AC and pulsating DC residual currents.