Kuangya KGLD series isolated dual power automatic transfer switch (ATS), covering 20A–3200A, designed for reliable power grid ↔ generator changeover.
Features fast switching, integrated ATS controller, motor drive mechanism, high dielectric withstand, and >8000 operations lifespan.
Suitable for hospitals, banks, high-rise buildings, industrial plants, and other critical applications requiring uninterrupted power supply.
그리고 KGLD Series Dual Power Automatic Transfer Switch (ATS) is a reliable dual power automatic transfer switch designed for switching between main and standby power or grid and generator.
With a compact design, high switching speed, and compliance with IEC 60947-6-1, the KGLD series ensures stable operation in critical facilities.
It provides automatic transfer, electrical and mechanical interlock, and an optional forced “0” position for maintenance.
Hospitals, banks, and data centers requiring continuous power
Industrial facilities using 자동 전송 스위치 equipment
Residential and commercial buildings with dual source power supply
Generator backup systems with dual power automatic transfer switch
Wide current range: 20–1600A, suitable for various ATS switch applications
Rated working voltage: AC400V, insulation up to 1000V
High short-circuit capacity: up to 120kA
Fast switching: conversion time 0.45s–1.2s
IEC 60947-6-1 / GB/T14048.11 ATS 표준 충족
Supports both manual and automatic transfer operation
Available in 3P and 4P models, ideal as a dual power automatic transfer switch for commercial and industrial projects
Rated Current (A) | Rated Insulation Voltage Ui (V) | Rated Impulse Withstand Voltage Uimp (kV) | Rated Working Voltage Ue (V) | AC-31A Rated Current (A) | AC-35A Rated Current (A) | AC-33A Rated Current (A) | Rated Making Capacity | Rated Breaking Capacity | Rated Limited Short Circuit Capacity (kA) | Rated Short-time Withstand Current (kA) | Conversion Time I↔II (s) | Control Voltage | Motor Power Start (W) | Motor Power Normal (W) | Weight (kg) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
20 | 750 | 8 | AC400 | 20 | 20 | 20 | 10 Ie | 8 Ie | 50 | 7 | 0.45 | AC220 | 300 | 55 | 7.0 |
40 | 750 | 8 | AC400 | 40 | 40 | 40 | 10 Ie | 8 Ie | 50 | 7 | 0.45 | AC220 | 300 | 55 | 7.0 |
63 | 750 | 8 | AC400 | 63 | 63 | 63 | 10 Ie | 8 Ie | 50 | 7 | 0.45 | AC220 | 300 | 55 | 7.2 |
80 | 750 | 8 | AC400 | 80 | 80 | 80 | 10 Ie | 8 Ie | 50 | 7 | 0.45 | AC220 | 300 | 55 | 7.2 |
100 | 750 | 8 | AC400 | 100 | 100 | 100 | 10 Ie | 8 Ie | 50 | 7 | 0.45 | AC220 | 300 | 55 | 7.5 |
125 | 750 | 8 | AC400 | 125 | 125 | 125 | 10 Ie | 8 Ie | 50 | 7 | 0.45 | AC220 | 325 | 62 | 7.5 |
160 | 750 | 8 | AC400 | 160 | 160 | 160 | 10 Ie | 8 Ie | 50 | 7 | 0.45 | AC220 | 335 | 62 | 8.8 |
250 | 750 | 8 | AC400 | 250 | 250 | 250 | 10 Ie | 8 Ie | 50 | 7 | 0.45 | AC220 | 335 | 62 | 9.0 |
400 | 750 | 8 | AC400 | 400 | 400 | 400 | 10 Ie | 8 Ie | 50 | 9 | 0.6 | AC220 | 335 | 74 | 16.5 |
630 | 750 | 8 | AC400 | 630 | 630 | 630 | 10 Ie | 8 Ie | 50 | 9 | 0.6 | AC220 | 335 | 74 | 17.0 |
800 | 1000 | 12 | AC400 | 800 | 800 | 800 | 10 Ie | 8 Ie | 70 | 13 | 1.2 | AC220 | 440 | 90 | 32.0 |
1000 | 1000 | 12 | AC400 | 1000 | 1000 | 800 | 10 Ie | 8 Ie | 70 | 26 | 1.2 | AC220 | 440 | 98 | 36.0 |
1250 | 1000 | 12 | AC400 | 1250 | 1000 | 800 | 10 Ie | 8 Ie | 100 | 50 | 1.2 | AC220 | 440 | 98 | 40.0 |
1600 | 1000 | 12 | AC400 | 1600 | 1600 | 1000 | 10 Ie | 8 Ie | 120 | 50 | 1.2 | AC220 | 440 | 98 | 43.0 |
The KGLD automatic transfer switch provides multiple wiring modes depending on system design, including:
Detailed wiring diagrams are available in the product catalog and should be strictly followed during installation.
The KGLD series conforms to the following international standards:
When choosing a KGLD automatic transfer switch, consider the following factors:
KGLD is motor-driven automatic ATS with wide current range (20–1600A), while KGQ2 focuses on molded case dual power switches with different application emphasis.
Yes. It supports grid-to-generator transfer, with automatic voltage detection and secure switching.
Yes, wiring modes include manual remote control and controller-based operation for smart systems.
Mechanical endurance ≥8000 operations, electrical endurance ≥6000 operations under rated conditions.
Yes, compliant with IEC 60947-6-1, IEC 60947-3, GB/T14048.11, and related standards.