  • rcbo unipolaire (1P+N) modular RCBO for single-phase branches, In 6–50A, tripping curves B/C.

  • Type AC / Type A, sensibilités IΔn 10 / 30 / 100 / 300 mA; Icn 6 kA / 10 kA @ 240 V, 50/60 Hz.

  • Certified SEMKO / UKCA / CE; standard IEC/EN 61009-1; front test button, DIN-rail mounting.

Obtenir un devis

Catégorie :

rcbo unipolaire VRL01 / VRL02 / VRL03 integrates residual-current and overcurrent protection in a compact 1P+N format, rated 6–50 A for 240 V, 50/60 Hz systems with Type AC/A and multiple IΔn options.

Vue d'ensemble

The VRL01 / VRL02 / VRL03 family is designed for single-phase distribution branches where
reliable residual-current protection and coordinated overcurrent performance are required.
Each variant shares the same 1P+N footprint and broad current range up to 50 A, with
selectable tripping curves (B/C), multiple residual sensitivities, and high breaking
capacity options (6/10 kA) to match fault levels on 240 V systems.

Caractéristiques principales

  • Facteur de forme : 1P+N (single-pole + neutral)
  • Courant nominal (In) : 6–50 A (typical steps: 6/10/16/20/25/32/40/50 A)
  • Tension nominale (Ue) : 240 V CA, 50/60 Hz
  • Type de courant résiduel : Type AC / Type A
  • Sensibilités (IΔn) : 10 / 30 / 100 / 300 mA
  • MCB tripping curves: B (3-5×In) et C (5-10×In)
  • Capacité de rupture (Icn) : 6 kA / 10 kA @ 240 V
  • Front test button (T); DIN-rail mounting; front wiring
  • Compliance & certification: IEC/EN 61009-1; SEMKO, UKCA, CE

RCBO Single Pole Technical Data — VRL01 / VRL02 / VRL03

ParamètresVRL01VRL02VRL03
Pôles1P+N (unipolaire + neutre)
Courant nominal (In)6–50 A6–50 A6–50 A
Tension nominale (Ue)240 V CA240 V CA240 V CA
Fréquence50/60 Hz
Type de courant résiduelType AC / Type A
Courant résiduel nominal (IΔn)10 / 30 / 100 / 300 mA
MCB tripping curveB : 3-5 × In ; C : 5-10 × In
Capacité de rupture (Icn)6 kA / 10 kA @ 240 V6 kA / 10 kA @ 240 V6 kA / 10 kA @ 240 V
InstallationRail DIN ; câblage frontal ; bouton de test (T)
Recommended useResidential & commercial branches (lighting / sockets) within 1P+N and ≤50 A
NormesIEC/EN 61009-1
CertificationsSEMKO, UKCA, CE

Applications

  • Apartments & houses: lighting/socket circuits up to 50 A
  • Commercial offices & retail: small-to-medium branch protection
  • Public facilities: classrooms, admin areas, auxiliary circuits
 

Normes et conformité

Conforms to IEC/EN 61009-1 with certifications SEMKO, UKCA, CE.
Coordinate with upstream protective devices; follow local codes for selectivity and fault levels.

FAQ

Do VRL01, VRL02 and VRL03 differ in core protection features?

All three share the same 1P+N format, 6–50 A range, Type AC/A residual options and B/C curves. They are part of the same platform with high breaking-capacity options (6/10 kA) for 240 V systems.

Which sensitivity (IΔn) should be used for sockets and lighting?

30 mA is most common for socket/lighting circuits. 10 mA is for higher touch-safety; 100/300 mA may be used per coordination and local code requirements.

How to choose between curve B and curve C?

Utiliser la courbe B (3-5×In) pour les charges résistives/légèrement inductives ; utiliser la courbe C (5-10×In) pour les circuits avec des appels de courant plus importants tels que les moteurs ou les transformateurs.

Avis

Il n’y a pas encore d’avis.

Soyez le premier à laisser votre avis sur “VRL01 / VRL02 / VRL03 RCBO — Single-Pole + Neutral (1P+N) 6–50A”

Votre adresse e-mail ne sera pas publiée. Les champs obligatoires sont indiqués avec *