RCCB VKL001 - Disjoncteur à courant résiduel

  • The Kuangya VKL001 rccb monophasé device disconnects circuits upon residual current, preventing electric shock and fire hazards.

  • 2P / 4P options; In 16–100 A; IΔn 10/30/100/300 mA; Ue 240 V (2P) / 415 V (4P); Inc = IΔc up to 10 kA; Uimp 6 kV.

  • Compliant with IEC/EN 61008-1; approvals: SEMKO, UKCA, CE.

Obtenir un devis

Catégorie :

Vue d'ensemble

The VKL001 rccb monophasé (also available for three-phase boards as 4P) detects earth-leakage
currents and trips before harm occurs, providing protection for people and installations. It is widely applied in
housing, the tertiary sector, and industry. Selection covers rated currents from 16 A to 100 A and residual
sensitivities from 10 mA to 300 mA.

Detection classes & selection

  • Classe AC — trips for slowly increasing sinusoidal AC residual currents, whether applied slowly or suddenly.
  • Une classe — all AC features plus tripping for pulsating DC residual currents, whether applied suddenly or increasing slowly.
  • High-immunity variants (Si/G/KV) — filters against spurious tripping caused by harmonics and transient surges; stable under 8/20 μs surge of 3000 A (per datasheet note).

Tripping sensitivity & time

  • 10 mA — precision instrument leakage protection and bathroom use (available on 2P/4P 16–40 A).
  • 30 mA — additional protection against direct contact.
  • 100 mA — coordinated with the earthing system for indirect contact protection.
  • 300 mA — protection against indirect contacts and fire hazards.
  • Instantaneous — tripping without intentional delay; break time under IΔn (Normal) ≤ 100 ms.
  • Short time delay (Si, G, KV) — ensures any tripping at least 10 ms (10–300 ms range).
  • Selective (S) — 150–500 ms, ensures discrimination with a downstream non-selective RCD.

Key features

  • Configurations : 2P / 4P; top or bottom supply; any mounting position.
  • Courant nominal In : 16, 25, 32, 40, 63, 80, 100 A.
  • Sensibilité nominale IΔn : 10 mA (2P/4P 16–40 A), 30 mA, 100 mA, 300 mA.
  • Tension nominale Ue : 2P: 240 V~; 4P: 415 V~. Ui : 500 V. Frequency: 50/60 Hz.
  • Residual making & breaking (IΔm): 500 A (In 16–40 A); 630 A (63 A); 800 A (80 A); 1000 A (100 A).
  • Conditional short-circuit (Inc = IΔc): 6000 A or 10000 A (with upstream SCPD coordination).
  • Impulse withstand (Uimp): 6 kV; Essai diélectrique : 2.5 kV (1 min at power frequency).
  • Endurance: ≥ 20,000 mechanical operations / ≥ 2000 electrical operations.
  • Terminal protection degree: IP20; Fault current indicator: Yes.
  • En milieu ambiant : −25 °C … +55 °C (daily avg ≤ 35 °C); Stockage : −40 °C … +70 °C.
  • Terminaux : cable / pin-type busbar; sizes (cable): 25–35 mm²; 18–3 / 18–2 AWG; sizes (busbar): 10/16 mm²; 18–8 / 18–5 AWG.
  • Tightening torque: 2.5 N·m (≈ 22 in-lbs).
  • Montage : DIN rail EN 60715 (35 mm), fast clip device; connection from top and bottom.
  • Standards & approvals: IEC/EN 61008-1; SEMKO, UKCA, CE.

Technical Data (full table)

StandardIEC/EN 61008-1
Model No.VKL001
Pôles2P, 4P
Courant nominal (In)16A, 25A, 32A, 40A, 63A, 80A, 100A
Sensibilité nominale (IΔn)10 mA (2P/4P 16-40 A), 30 mA, 100 mA, 300 mA
Tension nominale (Ue)2P: 240 V~; 4P: 415 V~
Insulation voltage (Ui)500 V
Rated frequency (fn)50/60 Hz
Rated residual making & breaking (IΔm)500 A (In = 16–40 A); 630 A (In = 63 A); 800 A (In = 80 A); 1000 A (In = 100 A)
Conditional short-circuit current (Inc = IΔc)6000 A; 10000 A
Type (waveform sensed)AC, A
Tripping time (Instantaneous)Break time under IΔn ≤ 100 ms
Tripping time (Short time delay)10–300 ms (Si, G, KV types)
Tripping time (Selective S)150-500 ms
Impulse withstand (Uimp)6 kV
Dielectric test voltage2.5 kV (1 min)
Pollution degree2
Electrical life≥ 2000 operations
Mechanical life≥ 20,000 operations
Fault current indicatorYes
Terminal protection degreeIP20
Ambient temperature−25 °C to +55 °C (daily avg ≤ 35 °C)
Température de stockage−40 °C to +70 °C
Terminal connection typeCâble / Barre collectrice à broches
Terminal size (cable)25–35 mm²; 18–3 / 18–2 AWG
Terminal size (busbar)10/16 mm²; 18–8 / 18–5 AWG
Tightening torque2.5 N·m (≈ 22 in-lbs)
MontageDIN rail EN 60715 (35 mm), fast clip
ConnexionTop and bottom
AgrémentsSEMKO, UKCA, CE

Applications

  • Single-phase boards requiring an rccb monophasé device at 240 V~ (2P).
  • Three-phase distribution at 415 V~ (4P) with coordination for 6/10 kA conditional short-circuit.
  • Loads with electronics and frequent transients — use high-immunity variants (Si/G/KV) to reduce nuisance trips.

rccb single phase VKL001 Kuangya 2P/4P 16–100A 10/30/100/300 mA