RCCB VKL11 (A/AC/ASi) - Interruptor diferencial residual

  • El Kuangya VKL11 4p rccb provides fast disconnection on earth-leakage to protect people and installations

  • 2P / 4P; In 16-100 A; IΔn 10/30/100/300 mA; Ue 240 V (2P) / 415 V (4P); Ui 500 V; 50/60 Hz

  • High-immunity ASi option to reduce nuisance trips; DIN-rail EN 60715; IP20 terminals

Solicitar presupuesto

Categoría:

Visión general

VKL11 is a residual current circuit breaker for 4p rccb applications in three-phase boards, with a 2P
version for single-phase systems. It detects earth-leakage current and disconnects the circuit to prevent electric
shock and fire hazards caused by insulation faults. Detection classes include CA, A,
y ASi (high-immunity) to suit different load characteristics and reduce nuisance tripping.

Características principales

  • Postes: 2P / 4P for single-phase and three-phase systems
  • Corriente nominal (In): 16, 25, 32, 40, 63, 80, 100 A
  • Sensibilidad nominal (IΔn): 10 / 30 / 100 / 300 mA
  • Tensión nominal (Ue): 240 V~ (2P) / 415 V~ (4P); Ui: 500 V; fn: 50/60 Hz
  • Residual making & breaking (IΔm): 500 / 630 / 800 / 1000 A (per In group)
  • Conditional short-circuit (Inc = IΔc): 6000 A / 10000 A (with upstream SCPD)
  • Impulse withstand (Uimp): 4 kV / 6 kV (by variant)
  • Protección de terminales: IP20; DIN-rail EN 60715 (35 mm) mounting

Datos técnicos

ModeloVKL11 (A/AC/ASi)
EstándarIEC/EN 61008-1
Postes2P, 4P
Corriente nominal (In)16A, 25A, 32A, 40A, 63A, 80A, 100A
Sensibilidad nominal (IΔn)10 mA, 30 mA, 100 mA, 300 mA
Tensión nominal (Ue)2P: 240 V~; 4P: 415 V~
Tensión de aislamiento (Ui)500 V
Frecuencia nominal50/60 Hz
Fabricación y rotura de residuos (IΔm)500 A (En 16-40 A); 630 A (63 A); 800 A (80 A); 1000 A (100 A)
Cortocircuito condicional (Inc = IΔc)6000 A; 10000 A (coord. with upstream SCPD)
Resistencia al impulso (Uimp)4 kV / 6 kV (por variante)
Grado de protección de los terminalesIP20
Temperatura ambienteDe -25 °C a +55 °C (media diaria ≤ 35 °C)
Temperatura de almacenamiento-40 °C a +70 °C
Conexión de terminalesCable / Barra colectora con pasador
Tamaño del terminal (cable)25-35 mm²
Tamaño del terminal (barra colectora)10/16 mm²
Par de apriete2,5 N-m
MontajeCarril DIN EN 60715 (35 mm)
ConexiónArriba y abajo
Waveform classAC, A, ASi (high-immunity)

Aplicaciones

  • Three-phase distribution boards using a 4p rccb for residual-current protection
  • Residential/commercial systems requiring discrimination or high-immunity (ASi) options
  • Installations coordinated with upstream SCPD for 6/10 kA conditional ratings

4p rccb VKL11 A/AC/ASi Kuangya 2P/4P 16–100A IΔn 10/30/100/300 mA

Valoraciones

No hay valoraciones aún.

Sé el primero en valorar “RCCB VKL11 (A/AC/ASi) — Residual Current Circuit Breaker”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *