RCCB VFL007 - Interruptor diferencial residual

  • Breaker RCCB designed for 2P and 4P systems, ensuring reliable leakage current protection

  • Rated current options: 16A–100A, sensitivity: 30mA / 100mA / 300mA

  • IEC/EN 61008-1 compliance, compact DIN rail mounting, long mechanical and electrical life

Solicitar presupuesto

Categoría:

Visión general

En VFL007 breaker RCCB is engineered to protect people and equipment from earth leakage currents,
preventing electric shocks and fire hazards. With 2 pole and 4 pole versions, it suits both residential and
industrial installations. The device complies with IEC/EN 61008-1
and provides dependable protection in diverse applications.

Características principales

  • Available in 2P and 4P configurations for single-phase and three-phase systems
  • Rated current range: 16A, 25A, 32A, 40A, 63A, 80A, 100A
  • Rated residual operating current (IΔn): 30mA, 100mA, 300mA
  • Rated voltage: 2P 240V, 4P 415V
  • Short-circuit capacity up to 10kA
  • Impulse withstand voltage: 6kV
  • Terminal protection: IP20
  • Operating temperature range: −25°C to +55°C
  • Test button for quick verification
  • DIN rail mounting with compact design

Technical Data

EstándarIEC/EN 61008-1
Postes2P, 4P
Rated Current In16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Sensitivity IΔn30 mA, 100 mA, 300 mA
Rated Voltage Ue2P: 240V / 4P: 415V
Frecuencia nominal50/60 Hz
Short-Circuit Capacity10kA
Impulse Withstand Voltage6kV
Terminal Size (cable)25–35 mm²
Terminal Size (busbar)18–8 AWG
Terminal Protection DegreeIP20
Mechanical Life≥ 2000 operations
Electrical Life≥ 2000 operations
Temperatura de funcionamiento−25°C to +55°C
Storage Temperature−40°C to +70°C
MontajeDIN rail EN 60715 (35mm)

Aplicaciones

The VFL007 breaker RCCB is suitable for multiple distribution systems where leakage protection is required:

  • 2 pole RCCB for residential distribution boards
  • 4 pole RCCB for industrial three-phase panels
  • Offices, schools, data centers, and public facilities
  • Integration with DC Surge Protective Devices y
    DC Fuses for enhanced protection

Certificaciones

  • IEC/EN 61008-1 compliance
  • Certificación CE
  • UKCA approval
  • Directiva RoHS

PREGUNTAS FRECUENTES

What is the purpose of the VFL007 breaker RCCB?

It disconnects the circuit when leakage current is detected, protecting against electric shocks and fire risks.

Can the VFL007 be used alone for overload protection?

No. RCCBs provide earth leakage protection only; MCBs or MCCBs must be combined for overload and short-circuit protection.

What are the available sensitivity options?

The VFL007 breaker RCCB supports 30mA, 100mA, and 300mA sensitivities for different applications.