VDL01 Interruptor automático RCBO - Protección de corriente residual ajustable 2P/4P (hasta 90A)

  • rcbo circuit breaker VDL01 with 2P/4P options and adjustable current pairs (5/15A → 60/90A), designed for mains/feeder protection.

  • Normal & Type S (time-delay) residual protection with IΔn 300 mA / 500 mA, coordinated selectivity for upstream devices.

  • Icn 3 kA, 230/240 V & 400/415 V, digital current display, anti-tamper design; built to NF C 61450 / NF C 62411 / IEC 61009.

Solicitar presupuesto

Categoría:

rcbo circuit breaker VDL01 is a two- or four-pole adjustable device combining residual-current and overcurrent protection for mains and feeder circuits, with selectable Normal and Type S (time-delay) characteristics.

Visión general

VDL01 integrates residual-current and overcurrent protection into a compact 2P/4P form.
It features adjustable current pairs to match upstream/downstream coordination and
offers Normal y Tipo S (time-delay) residual functions with higher
sensitivities (IΔn 300 mA / 500 mA) suitable for main/feeder selectivity.
A digital current display and anti-tamper design improve on-site setting and security.

Características principales

  • Postes: 2P y 4P for single- and three-phase systems
  • Adjustable current pairs: 5/15 A, 10/30 A, 15/45 A, 30/60 A, 60/90 A
  • Residual modes: Normal & Tipo S (time-delay for selective protection)
  • Sensibilidad (IΔn): 300 mA / 500 mA
  • Capacidad de rotura (Icn): 3 kA
  • Tensión nominal: 230/240 V y 400/415 V, 50/60 Hz
  • Digital current display; anti-tamper design; temperature-insensitive operation
  • Standards: NF C 61450, NF C 62411, IEC 61009

RCBO Circuit Breaker Technical Data — VDL01

ParámetroVDL01 (2P)VDL01 (4P)
Postes2P4P
Adjustable current pairs (A)5/15, 10/30, 15/45, 30/60, 60/90
Tensión nominal (Ue)230/240 V400/415 V
Frecuencia50/60 Hz
Residual modeNormal / Type S (time-delay)
Corriente residual nominal (IΔn)300 mA / 500 mA
Capacidad de rotura (Icn)3 kA
Indication / InterfaceDigital current display; anti-tamper design
Temperature sensitivityInsensitive (per product note)
NormasNF C 61450; NF C 62411; IEC 61009

Aplicaciones

  • Mains and feeder circuits requiring selective residual protection (Type S)
  • Commercial and public buildings with coordinated upstream devices
  • Three-phase distribution where 4P selectivity and higher IΔn are needed
  • Panels needing adjustable current pairs for field tuning
 

Normas y conformidad

Designed in accordance with NF C 61450, NF C 62411y IEC 61009. Check local codes for selectivity and discrimination requirements.

PREGUNTAS FRECUENTES

What does Type S mean on VDL01?

Type S is a time-delay residual function that helps achieve selectivity with downstream RCD/RCBOs, reducing nuisance trips on mains/feeder circuits.

How do the adjustable current pairs work?

You can select among 5/15, 10/30, 15/45, 30/60, and 60/90 A pairs to match the protected feeder and upstream device, using the built-in digital display to verify settings.

When should I choose 4P over 2P?

Use 4P for three-phase systems or when neutral switching and full four-pole isolation are required; 2P fits single-phase feeders.

Which IΔn should I use?

VDL01 offers 300 mA and 500 mA suited for upstream selectivity. Choose per local codes and coordination studies.

Valoraciones

No hay valoraciones aún.

Sé el primero en valorar “VDL01 RCBO Circuit Breaker — 2P/4P Adjustable Residual Current Protection (up to 90A)”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *