  • Surge protective device type 3 for single-phase 2P (L+N) 230 V AC systems.

  • Surge ratings: In 3 kA (8/20 µs), Imax 6 kA (8/20 µs), Up ≤ 1.0–1.5 kV en función de Uc.

  • Compact module for terminal equipment protection, quick DIN-rail mounting, optional RC signaling contacts.

Solicitar presupuesto

Categoría:
The Kuangya KYSPD-T3-2P is a dedicated dispositivo de protección contra sobretensiones tipo 3
designed for fine protection of sensitive equipment at the terminal level of electrical
systems. It is applied in 230 V single-phase networks, safeguarding electronics,
computers, communication devices, and control circuits against transient surges.Using MOV-based suppression elements, this SPD offers reliable performance
with fast response time, compact size, and DIN-rail installation.
Integrated thermal disconnectors and visible fault indicators ensure safety,
while optional RC contacts provide remote fault monitoring.

Características principales

  • Type 3 SPD according to IEC/EN 61643-11 (Class III protection).
  • Nominal discharge current (In): 3 kA (8/20 μs).
  • Maximum discharge current (Imax): 6 kA (8/20 μs).
  • Voltage protection level (Up): ≤ 1.0–1.5 kV depending on Uc.
  • Response time < 25 ns for rapid surge suppression.
  • Back-up fuse: max 32 A gL/gG; ISCCR 6 kA AC.
  • Compact 2P design for terminal or downstream protection.
  • Optional RC contacts for remote signaling (AC 250 V / 0.5 A; DC 250 V / 0.1 A).
  • Housing IP20, UL94 V-0 thermoplastic; operating temperature -40 °C to +70 °C.
  • 35 mm DIN rail mounting; IEC/EN 61643-11 compliant.

Especificaciones

Código del productoKYSPD-T3-2P
CategoríaSurge protective device type 3
Tensión nominal del sistema230 V AC
Postes2P (L+N)
Tensión de funcionamiento continuo (Uc)275 V AC
Corriente nominal de descarga (In, 8/20 μs)3 kA
Corriente de descarga máxima (Imax, 8/20 μs)6 kA
Nivel de protección de tensión (arriba)≤ 1.0–1.5 kV
Tiempo de respuesta< 25 ns
Fusible de reserva (máx.)32 A gL/gG
Corriente nominal de cortocircuito (ISCCR)6 kA AC
Temperatura de funcionamiento-40 °C to +70 °C
MontajeCarril DIN de 35 mm, EN 60715
Cerramiento / ProtecciónTermoplástico UL94 V-0 / IP20
Señalización remota (RC)Optional; AC 250 V / 0.5 A; DC 250 V / 0.1 A
NormasCEI/EN 61643-11

Cableado y dimensiones

Connection diagram surge protective device type 3 KYSPD-T3-2P

Connection diagram surge protective device type 3 KYSPD-T3-2P

 

Dimensions surge protective device type 3 KYSPD-T3-2PDimensions surge protective device type 3 KYSPD-T3-2P

Aplicaciones

  • Protection of terminal equipment such as computers, routers, and servers.
  • Applied in residential, commercial, and industrial single-phase panels.
  • Supplementary fine protection coordinated with upstream Type 2 SPDs.

PREGUNTAS FRECUENTES

  • What class is KYSPD-T3-2P? It is Class III, Type 3 SPD according to IEC/EN 61643-11.
  • What is its discharge capacity? In 3 kA, Imax 6 kA.
  • What applications is it designed for? Terminal-level protection of electronics in 230 V AC systems.
  • Does it have remote signaling? Yes, optional RC contacts can be provided.
  • What is the max backup fuse rating? 32 A gL/gG.
Para precios detallados y asistencia técnica, por favor ContactoExplore más soluciones Kuangya: DC SPD, Protección contra sobretensiones de CA.

Valoraciones

No hay valoraciones aún.

Sé el primero en valorar “Surge Protective Device Type 3 KYSPD-T3-2P | Kuangya”