VDL01 RCBO-Leistungsschalter - 2P/4P einstellbarer Fehlerstromschutz (bis zu 90A)

  • rcbo circuit breaker VDL01 with 2P/4P options and adjustable current pairs (5/15A → 60/90A), designed for mains/feeder protection.

  • Normal & Type S (time-delay) residual protection with IΔn 300 mA / 500 mA, coordinated selectivity for upstream devices.

  • Icn 3 kA, 230/240 V & 400/415 V, digital current display, anti-tamper design; built to NF C 61450 / NF C 62411 / IEC 61009.

Angebot einholen

Kategorie:

rcbo circuit breaker VDL01 is a two- or four-pole adjustable device combining residual-current and overcurrent protection for mains and feeder circuits, with selectable Normal and Type S (time-delay) characteristics.

Übersicht

VDL01 integrates residual-current and overcurrent protection into a compact 2P/4P form.
It features adjustable current pairs to match upstream/downstream coordination and
offers Normal und Typ S (time-delay) residual functions with higher
sensitivities (IΔn 300 mA / 500 mA) suitable for main/feeder selectivity.
A digital current display and anti-tamper design improve on-site setting and security.

Wesentliche Merkmale

  • Pole: 2P und 4P for single- and three-phase systems
  • Adjustable current pairs: 5/15 A, 10/30 A, 15/45 A, 30/60 A, 60/90 A
  • Residual modes: Normal & Typ S (time-delay for selective protection)
  • Empfindlichkeit (IΔn): 300 mA / 500 mA
  • Ausschaltvermögen (Icn): 3 kA
  • Nennspannung: 230/240 V und 400/415 V, 50/60 Hz
  • Digital current display; anti-tamper design; temperature-insensitive operation
  • Normen: NF C 61450, NF C 62411, IEC 61009

RCBO Circuit Breaker Technical Data — VDL01

ParameterVDL01 (2P)VDL01 (4P)
Pole2P4P
Adjustable current pairs (A)5/15, 10/30, 15/45, 30/60, 60/90
Nennspannung (Ue)230/240 V400/415 V
Frequenz50/60 Hz
Residual modeNormal / Type S (time-delay)
Bemessungsfehlerstrom (IΔn)300 mA / 500 mA
Ausschaltvermögen (Icn)3 kA
Indication / InterfaceDigital current display; anti-tamper design
Temperature sensitivityInsensitive (per product note)
NormenNF C 61450; NF C 62411; IEC 61009

Anwendungen

  • Mains and feeder circuits requiring selective residual protection (Type S)
  • Commercial and public buildings with coordinated upstream devices
  • Three-phase distribution where 4P selectivity and higher IΔn are needed
  • Panels needing adjustable current pairs for field tuning
 

Normen und Einhaltung

Designed in accordance with NF C 61450, NF C 62411und IEC 61009. Check local codes for selectivity and discrimination requirements.

FAQ

What does Type S mean on VDL01?

Type S is a time-delay residual function that helps achieve selectivity with downstream RCD/RCBOs, reducing nuisance trips on mains/feeder circuits.

How do the adjustable current pairs work?

You can select among 5/15, 10/30, 15/45, 30/60, and 60/90 A pairs to match the protected feeder and upstream device, using the built-in digital display to verify settings.

When should I choose 4P over 2P?

Use 4P for three-phase systems or when neutral switching and full four-pole isolation are required; 2P fits single-phase feeders.

Which IΔn should I use?

VDL01 offers 300 mA and 500 mA suited for upstream selectivity. Choose per local codes and coordination studies.

Rezensionen

Es gibt noch keine Rezensionen.

Schreibe die erste Rezension für „VDL01 RCBO Circuit Breaker — 2P/4P Adjustable Residual Current Protection (up to 90A)“

Deine E-Mail-Adresse wird nicht veröffentlicht. Erforderliche Felder sind mit * markiert