rcbo single pole (1P+N) RCBO for residential & commercial branches, In 5–40A, curves B/C.
Type AC / Type A, sensitivities IΔn 6 / 10 / 30 / 100 / 300 mA; Icn up to 10 kA @ 240 V (VKL003) / 15 kA @ 120 V (VKL003N).
SEMKO / UKCA / CE / SAA certified; electrical & mechanical endurance 2,000 cycles; DIN-rail mounting with front test button.
rcbo single pole VKL003 / VKL003N is a compact 1P+N residual-current circuit breaker with overcurrent protection, rated 5–40 A with Type AC/A, multiple sensitivities, and B/C curves for residential and commercial distribution circuits.
VKL003 and VKL003N provide combined protection against overload, short circuit, and
residual current faults on single-phase branches. Both share the same 1P+N form factor
and current range (5–40 A). VKL003 targets 240 V systems with breaking capacity
up to 10 kA, while VKL003N is optimized for 120 V systems with
15 кА Icn. Type AC and Type A options plus five sensitivity levels enable precise
coordination across lighting and socket circuits.
Параметр | VKL003 | VKL003N |
---|---|---|
Поляки | 1P+N (single-pole + neutral) | |
Rated current (In) | 5–40 A | 5–40 A |
Rated voltage (Ue) | AC 240 V | AC 120 V |
Частота | 50/60 Hz | |
Residual current type | Type AC / Type A | |
Rated residual current (IΔn) | 6 / 10 / 30 / 100 / 300 mA | |
Tripping characteristic (MCB curve) | B: 3–5 × In; C: 5–10 × In | |
Breaking capacity (Icn) | 4.5 / 6 / 10 kA @ 240 V | 15 kA @ 120 V |
Выносливость | Electrical 2,000 cycles; Mechanical 2,000 cycles | |
Установка | DIN-rail; front wiring; test button (T) | |
Recommended applications | Residential & commercial lighting and socket branches | |
Сертификаты | SEMKO, UKCA, CE, SAA | |
Стандарты | IEC/EN 61009-1 |
Conforms to IEC/EN 61009-1. Certified by SEMKO, UKCA, CE, SAA.
Coordinate with upstream protection and follow local codes for selectivity and fault levels.
Both are 1P+N, 5–40 A with Type AC/A and five IΔn levels. VKL003 is for 240 V (up to 10 kA Icn); VKL003N is for 120 V (15 kA Icn).
Use curve B (3–5×In) for resistive/lightly inductive loads; use curve C (5–10×In) for circuits with higher inrush such as motors or transformers.
The compact 1P+N layout saves rail width while providing full residual and overcurrent protection—ideal for lighting and socket branches.
Отзывы
Отзывов пока нет.