VFL005 Disjuntor tipo RCCB - 2P e 4P Proteção contra corrente residual

  • Circuit breaker RCCB type for reliable residual current protection in residential and industrial systems

  • Available in 2 pole & 4 pole versions, rated current options 16A to 100A, sensitivity from 30mA to 300mA

  • Compliant with IEC/EN 61008-1, featuring high short-circuit withstand capacity and compact installation

Obter uma cotação

Categoria:

Visão geral

O VFL005 circuit breaker RCCB type provides effective protection against leakage current, electric shocks,
and fire hazards caused by ground faults. Designed with 2P and 4P configurations, it ensures reliable safety in both
residential and commercial installations. The unit complies with IEC/EN 61008-1 padrões.

Principais recursos

  • 2P and 4P residual current circuit breaker with rated currents from 16A to 100A
  • Sensitivity options: 30mA, 100mA, 300mA for flexible protection levels
  • Rated voltage: 2P up to 240V, 4P up to 415V
  • Short-circuit withstand capacity up to 10kA
  • High surge immunity up to 6kV
  • Test button for functional verification
  • Terminal protection degree: IP20
  • Operating temperature: −25°C to +55°C

Dados técnicos

PadrãoIEC/EN 61008-1
Postes2P, 4P
Corrente nominal em16A, 25A, 32A, 40A, 63A, 80A, 100A
Sensibilidade nominal IΔn30mA, 100mA, 300mA
Tensão nominal Ue2P: 240V / 4P: 415V
Frequência nominal50/60Hz
Capacidade de curto-circuito10kA
Tensão de resistência a impulsos6kV
Terminal Size for Cable25-35 mm²
Terminal ProtectionIP20
Vida mecânica≥ 2000 operações
Vida elétrica≥ 2000 operações
MontagemTrilho DIN EN 60715 (35 mm)

Aplicativos

The VFL005 circuit breaker RCCB type is suitable for residential, commercial, and industrial distribution systems.
Common applications include:

  • 2 pole RCCB for single-phase home distribution boards
  • 4 pole RCCB for three-phase industrial panels
  • Protection in offices, data centers, and critical facilities
  • Integration with other devices such as DC SPD,
    Fusível CCe Miniature Circuit Breakers

Certificações

  • Conformidade com a norma IEC/EN 61008-1
  • CE certified
  • UKCA compliant
  • Diretriz RoHS

PERGUNTAS FREQUENTES

What is the difference between a 2P and 4P RCCB?

2P RCCBs are used in single-phase systems, while 4P RCCBs are designed for three-phase systems. The choice depends on the type of installation.

Does the VFL005 circuit breaker RCCB type protect against overload?

No, RCCBs are intended for residual current (earth leakage) protection. Overcurrent and short-circuit protection require an MCB or MCCB in combination.

What are the available rated currents for VFL005?

The VFL005 supports 16A, 25A, 32A, 40A, 63A, 80A, and 100A configurations.

Avaliações

Não há avaliações ainda.

Seja o primeiro a avaliar “VFL005 Circuit Breaker RCCB Type – 2P & 4P Residual Current Protection”

O seu endereço de e-mail não será publicado. Campos obrigatórios são marcados com *