Dispositivo de proteção contra surtos de 240V KYSPD-20T2+3-3P+1N | Kuangya

  • 240V surge protection device com 3+1 topology (L1-L2-L3-N) for 230/400 V AC networks.

  • Surge ratings: In 10 kA (8/20 µs), Imax 20 kA (8/20 µs), Up ≤ 0.3–1.8 kV depending on Uc.

  • Combines MOV + GDT technology for L–N and N–PE coordinated protection, pluggable modules, optional RC signaling contacts.

Obter uma cotação

Categoria:
The Kuangya KYSPD-20T2+3-3+1 is a 240V surge protection device designed for three-phase + neutral systems at 230/400 V AC. It uses a 3+1 topology, with MOV protection for L–N and coordinated GDT+MOV protection for N–PE, offering reliable suppression of transient overvoltages from lightning and switching surges.Its compact pluggable cartridge design allows easy replacement, while integrated thermal disconnectors ensure safe operation. Visual green/red indicators provide status feedback, and optional RC contacts enable remote fault monitoring.

Principais recursos

  • Class II+III / Type 2+3 surge protection device with 3+1 topology.
  • Nominal discharge current (In): 10 kA (8/20 μs).
  • Maximum discharge current (Imax): 20 kA (8/20 μs).
  • Voltage protection level (Up): ≤ 0.3–1.8 kV depending on Uc (75–440 V).
  • Response time: < 25 ns (L–N), < 100 ns (N–PE).
  • Back-up fuse: max 63 A gL/gG; ISCCR 10 kA AC.
  • Pluggable module, thermal disconnector, green/red fault status indicator.
  • Optional RC remote signaling contacts for BMS/PLC integration.
  • Housing IP20, UL94 V-0 thermoplastic; operating temperature -40 °C to +70 °C.
  • DIN rail mounting (35 mm, EN 60715); IEC/EN 61643-11 compliant.

Especificações

Código do produtoKYSPD-20T2+3-3+1
Categoria240V surge protection device
Tensão nominal do sistema230/400 V AC
Topology3+1 (L–N MOV, N–PE GDT+MOV)
Continuous Operating Voltage (Uc)75 / 150 / 275 / 320 / 385 / 440 V
Corrente de descarga nominal (In, 8/20 μs)10 kA
Maximum Discharge Current (Imax, 8/20 μs)20 kA
Nível de proteção de tensão (para cima)≤ 0.3–1.8 kV
Tempo de resposta< 25 ns (L–N), < 100 ns (N–PE)
Back-Up Fuse (max)63 A gL/gG
Classificação de corrente de curto-circuito (ISCCR)10 kA AC
Temperatura operacional-40 °C to +70 °C
Montagem35 mm DIN rail, EN 60715
Enclosure / ProtectionThermoplastic UL94 V-0 / IP20
Remote Signaling (RC)Optional; AC 250 V / 0.5 A; DC 250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A
PadrõesIEC/EN 61643-11

Fiação e dimensões

Connection diagram 240V surge protection device KYSPD-20T2+3-3+1

Connection diagram 240V surge protection device KYSPD-20T2+3-3+1

Dimensions 240V surge protection device KYSPD-20T2+3-3+1

Dimensions 240V surge protection device KYSPD-20T2+3-3+1

Aplicativos

  • Main distribution boards in residential and commercial buildings (240V systems).
  • Protection of elevators, industrial control systems, and sensitive electronics.
  • Panels requiring coordinated 3+1 surge protection in TT/TN-S networks.

PERGUNTAS FREQUENTES

  • What topology does KYSPD-20T2+3-3+1 use? It uses 3+1 topology: L–N MOV, N–PE GDT+MOV.
  • What is its surge discharge capacity? In 10 kA, Imax 20 kA.
  • Where is it applied? In 230/400 V AC three-phase + N systems, especially 240V distribution panels.
  • Does it support monitoring? Yes, optional RC contacts provide remote signaling.
  • What is the maximum back-up fuse rating? 63 A gL/gG.
For detailed pricing and technical support, please Entre em contato conosco.Explore more Kuangya solutions: DC SPD, AC Surge Protection.

Avaliações

Não há avaliações ainda.

Seja o primeiro a avaliar “240V Surge Protection Device KYSPD-20T2+3-3P+1N | Kuangya”

O seu endereço de e-mail não será publicado. Campos obrigatórios são marcados com *