240V Surge Protection Device KYSPD-25T1-3+1 | Kuangya

  • Quatro polos Dispositivo de proteção contra surtos de 240 V (3+1) design for TN-S and TT systems.

  • Withstands Iimp 25 kA (10/350 μs) per pole, In 25 kA, Imax 100 kA.

  • Pluggable cartridge with indicator window; optional RC contacts; DIN rail mount.

Obter uma cotação

Categoria:
The Kuangya KYSPD-25T1-3+1 is a four-pole Dispositivo de proteção contra surtos de 240 V designed for electrical panels in 230/400 V AC systems. With its 3+1 configuration, it provides enhanced protection for phase-to-neutral and neutral-to-earth paths. This Dispositivo de proteção contra surtos de 240 V is tested according to IEC/EN 61643-11 and withstands lightning currents up to Iimp 25 kA per pole (10/350 μs). It is ideal for service entrance installations where reliable first-stage protection is required.

Principais recursos

  • Em conformidade com a norma IEC/EN 61643-11, Classe I / Tipo 1.
  • 3+1 configuration: three phases plus neutral-to-earth protection.
  • Iimp 25 kA (10/350 μs) per pole; In 25 kA; Imax 100 kA.
  • Nominal system voltage Uo/Un: 230/400 V AC; suitable as a Dispositivo de proteção contra surtos de 240 V.
  • Uc options: 320 / 385 / 440 V AC; voltage protection level (Up): ~1.6–2.0 kV.
  • Tempo de resposta < 25 ns.
  • Pluggable replaceable cartridge with thermal disconnector and visual indicator.
  • Contatos RC opcionais para sinalização remota.
  • Carcaça de termoplástico UL94 V-0; IP20 embutido; montagem em trilho DIN 35 mm.

Especificações

ParâmetroValor
Código do produtoKYSPD-25T1-3+1
Categoria240V Surge Protection Device (Type 1 / Class I)
Tensão nominal do sistema (Uo/Un)230 / 400 V CA
Máx. Tensão operacional contínua (Uc)320 / 385 / 440 V CA
Corrente de descarga nominal (In, 8/20 μs)25 kA
Máx. Corrente de descarga (Imax, 8/20 μs)100 kA
Corrente de descarga de impulso (Iimp, 10/350 μs)25 kA por polo
Nível de proteção de tensão (para cima)~1,6-2,0 kV
Tempo de resposta< 25 ns
Classificação de corrente de curto-circuito (ISCCR)50 kA
Fusível de reserva (máx.)315 A gL/gG
Temperatura operacional-40 °C ... +70 °C
MontagemTrilho DIN de 35 mm (EN 60715)
GabineteTermoplástico, UL94 V-0
Grau de proteçãoIP20 (embutido)
Sinalização remotaContatos RC opcionais
PadrõesIEC 61643-11 / EN 61643-11

Isso Dispositivo de proteção contra surtos de 240 V is recommended for TN-S and TT earthing systems, delivering reliable first-stage lightning current handling.

Fiação e dimensões

  • Diagrama de conexão: kyspd-25t1-3+1-connection
  • 240v surge protection device 3+1 wiring diagram
  • Dimensões: kyspd-25t1-3+1-dimensions
  • 240v surge protection device 3+1 dimensions

Aplicativos

  • Service entrance protection for low-voltage panels.
  • Primeiro estágio Dispositivo de proteção contra surtos de 240 V in coordinated systems with Type 2 and Type 3 SPDs.
  • Commercial and industrial electrical panels requiring robust lightning protection.

PERGUNTAS FREQUENTES

Where should KYSPD-25T1-3+1 be installed?

It should be installed at the service entrance or main panel as a Dispositivo de proteção contra surtos de 240 V.

Qual é a classificação da corrente de descarga de impulso?

O Dispositivo de proteção contra surtos de 240 V withstands Iimp 25 kA per pole (10/350 μs).

Can this device be used in TT systems?

Yes, the 3+1 design makes it suitable for TT as well as TN-S systems.

How can the module be replaced?

The pluggable cartridge design makes this Dispositivo de proteção contra surtos de 240 V easy to service.

Does it support remote monitoring?

Yes, optional RC terminals are available for remote signaling.

Com quais padrões ele está em conformidade?

IEC/EN 61643-11 for AC surge protective devices.

Obter uma cotação - Produtos relacionados: AC MCB, Chave de transferência manual

Avaliações

Não há avaliações ainda.

Seja o primeiro a avaliar “240V Surge Protection Device KYSPD-25T1-3+1 | Kuangya”

O seu endereço de e-mail não será publicado. Campos obrigatórios são marcados com *