rcbo single pole (1P+N) for residential & commercial circuits, In 5–40A, curves B/C.
Type AC / Type A, sensitivities 6 / 10 / 30 / 100 / 300 mA; Icn up to 10 kA @240V (VAL003) / 15 kA @120V (VAL003N).
Certified SEMKO / UKCA / CE / SAA; electrical & mechanical endurance 2,000 cycles.
rcbo polo único VAL003 / VAL003N delivers combined residual-current and overcurrent protection in a compact 1P+N form factor (5–40 A), with Type AC/A, multiple IΔn options and B/C curves for residential and commercial circuits.
VAL003 and VAL003N are compact modular RCBOs designed to provide combined protection against overload, short-circuit and residual current faults on single-phase distribution branches. Both variants share the same compact 1P+N footprint and current range (5–40 A), while their rated voltage and breaking capacity differ to fit regional grids: VAL003 targets 240 V systems (up to 10 kA Icn), and VAL003N targets 120 V systems (up to 15 kA Icn). With selectable residual current types (AC / A) and multiple sensitivities (6 / 10 / 30 / 100 / 300 mA), the series suits residential, commercial and light industrial applications where space efficiency and reliable nuisance-trip control are required.
Parâmetro | VAL003 | VAL003N |
---|---|---|
Postes | 1P+N (single-pole + neutral) | |
Rated current (In) | 5–40 A | 5–40 A |
Rated voltage (Ue) | AC 240 V | AC 120 V |
Frequência | 50/60 Hz | |
Residual current type | Type AC / Type A | |
Rated residual current (IΔn) | 6 / 10 / 30 / 100 / 300 mA | |
Tripping characteristic (MCB curve) | B: 3–5 × In; C: 5–10 × In | |
Breaking capacity (Icn) | 4.5 / 6 / 10 kA @ 240 V | 15 kA @ 120 V |
Resistência | Electrical: 2,000 cycles; Mechanical: 2,000 cycles | |
Padrões | IEC/EN 61009-1 | |
Certificações | SEMKO, UKCA, CE, SAA | |
Instalação | DIN-rail mounting; front wiring; test button (T) | |
Recommended applications | Residential branch circuits, commercial lighting & sockets, small equipment feeds |
Conforms to IEC/EN 61009-1, with certifications SEMKO, UKCA, CE, and SAA.
Refer to local codes for coordination and selectivity with upstream protective devices.
They share the same 1P+N form factor and current range (5–40 A) and support both Type AC and Type A residual protections. VAL003 targets 240 V grids with up to 10 kA Icn; VAL003N targets 120 V grids with 15 kA Icn.
6 / 10 / 30 / 100 / 300 mA. For typical socket and lighting circuits, 30 mA is most common; 6–10 mA may be used for higher touch-safety requirements; 100–300 mA are generally for special coordination scenarios per local codes.
Use curve B (3–5×In) for resistive/lightly inductive loads; use curve C (5–10×In) for circuits with higher inrush (e.g., motors, transformers). Always verify with upstream protection and local standards.
Yes, within its ratings (1P+N, up to 40 A). For larger currents, three-phase systems, or special waveforms (e.g., EV / Type B), choose other series models accordingly.