A DC surge protective device (SPD) limits transient overvoltage and diverts surge current away from equipment. For solar PV, the key questions are where the device is installed, whether it is rated for the maximum PV open-circuit voltage at the lowest expected temperature, and how it coordinates with the inverter and other protective devices. This guide focuses on the PV DC side; battery, EV and telecom DC systems require separate application checks.
A surge may be induced by nearby lightning or switching. An SPD connected across the relevant conductors remains non-conducting under normal voltage and conducts during a transient, limiting the voltage seen by equipment. It is one part of a protection system: bonding, earthing, cable routing and appropriately rated overcurrent protection still matter. An SPD cannot guarantee survival of a direct strike or replace a fuse or circuit breaker.

IEC 61643-31 specifies test requirements for SPDs on the DC side of PV generators and inverters with rated voltages up to 1,500 V DC. Its scope excludes PV systems that include energy storage. IEC 61643-32 provides application guidance for PV SPD selection, installation and coordination. For a battery or another low-voltage DC application, check the applicable product standard and the exact device certification; a PV-only declaration is not proof of suitability for that circuit.
Type 1/Class I devices are tested for lightning-current impulses; Type 2/Class II devices are tested for induced and switching surges. The required class and placement depend on the building lightning protection system, separation distance, local installation rules and the project risk assessment. A rooftop array does not automatically require Type 1, and an open-field array does not automatically make one specific device or position correct. Use the project lightning-protection design and the manufacturer’s coordination instructions.
Review the array or combiner-box side, the inverter DC input and the AC side of the inverter as separate protection points. The number and position of SPDs depend on cable lengths, earthing arrangement and equipment withstand ratings. Keep SPD connections short and route conductors according to the installation instructions; long leads can increase the voltage reaching equipment. See our guia de proteção de inversores solares e PV protection overview for the wider design context.
Do not assume that an AC-only SPD is suitable for a PV DC string. The continuous voltage, disconnection behavior, available fault current and certification must all match the DC application. Read our AC SPD on DC systems article for the failure modes and selection checks.
These systems have different voltage ranges, source behavior and fault-current conditions. Do not transfer a PV SPD specification automatically to a battery rack or EV charging DC bus. Obtain the device’s declared application and test standard, check maximum continuous voltage and fault current, and follow the system integrator’s protection design. For context, see our EV charging and energy storage article.
A reliable price comparison needs the same application, voltage rating, test class, discharge ratings, pole configuration, enclosure and certification documents. Generic online price bands do not establish that a device is suitable for a particular installation. Ask the supplier for the model-specific datasheet, declaration or test report, wiring diagram, backup-protection requirements and quotation.
The nominal system label alone is insufficient. Calculate the array’s maximum open-circuit voltage at the lowest design temperature and compare it with the SPD’s stated UCPV. Also verify the connection scheme, fault-current conditions and manufacturer instructions. There is no universal 1.2× multiplier that can replace this calculation.
No. Compare the same test waveform and class, then consider voltage protection level, continuous voltage rating, installation location and coordination. A larger single rating cannot compensate for an unsuitable voltage rating or incorrect wiring.
The safest way to choose a DC SPD is to start with the actual circuit and the equipment to be protected, then verify the device’s ratings, application scope and installation instructions. For PV projects, use IEC 61643-31 product documentation and IEC 61643-32 application guidance alongside local rules. Explore Kuangya DC SPD products and request model-specific technical documents before specifying a device.