Type A RCD prices in Spain vary widely because buyers are often comparing different devices under the same name. A 2-pole 40 A / 30 mA RCCB, a 4-pole industrial RCCB and a Type A RCBO have different functions, certifications and price structures. The fastest way to obtain a useful quotation is to specify the exact device, quantity and compliance documents required.
Buyer summary: compare quotations by RCD type, poles, rated current (In), rated residual operating current (IΔn), product standard, short-circuit coordination, certificate scope, delivery terms and warranty. Do not assume that Type A is mandatory for every circuit in Spain; select the RCD type from the connected equipment, Spain’s REBT requirements, applicable UNE/HD standards and project specifications.
There is no official fixed “Type A RCD Spain price.” Local retail prices, distributor project prices and factory OEM quotations serve different markets. VAT, shipping, customs, certification, accessories and order quantity can change the landed cost more than the basic device price.
| Product being quoted | Typical price position | Main cost drivers |
|---|---|---|
| 2P Type A RCCB | Usually the lowest-cost Type A option | In, IΔn, brand, certification and order quantity |
| 4P Type A RCCB | Higher than a comparable 2P device | Additional poles, current rating and enclosure size |
| Tipo A RCBO | Higher unit price than an RCCB | Integrated overload and short-circuit protection, breaking capacity and trip curve |
| Type F or Type B RCD | Normally higher than Type A | Broader residual-current waveform capability and product design |
| AFDD with residual-current protection | Premium category | Arc-fault detection, RCBO functions, poles and certification |
Online prices such as €8–€25 for basic Type A RCCBs or €15–€45 for some Type A RCBOs may appear in market listings, but they are not reliable project budgets without checking the exact rating, tax status, origin, certification and quantity. Obtain a dated quotation for procurement decisions.
| Required detail | Exemplo | Why it changes the price |
|---|---|---|
| Device function | RCCB or RCBO | An RCCB needs separate overcurrent protection; an RCBO integrates it |
| Postes | 2P or 4P | Pole count changes construction, size and cost |
| Corrente nominal Em | 25 A, 40 A, 63 A or another rating | Determines current-carrying capability |
| Sensitivity IΔn | 30 mA, 100 mA or 300 mA | Defines residual-current operating characteristic |
| Tipo de RCD | Type A, F or B | Different residual-current waveforms require different designs |
| RCBO details | B/C curve and breaking capacity | Overcurrent characteristics apply to RCBOs, not a plain RCCB in the same way |
| Quantidade | Samples, cartons or annual forecast | Tooling, testing, packing and freight are spread across the order |
| Commercial terms | EXW, FOB, CIF or DDP | Determines which logistics and import costs are included |
Spain’s low-voltage framework is based on the Reglamento Electrotécnico para Baja Tensión (REBT) and its technical instructions. The Ministry’s application guide for ITC-BT-24 describes Type AC, A, F and B residual-current devices and their waveform capabilities. This supports selecting the appropriate type for the circuit; it does not support a blanket claim that every Spanish final circuit must use Type A.
For household and similar RCCBs without integral overcurrent protection, the relevant product family is IEC/EN 61008. RCBOs with integral overcurrent protection fall under IEC/EN 61009. AENOR certification can be valuable when a tender or customer requests it, but it should not be presented as universally mandatory for every product sold in Spain. Verify the project specification.
A Tipo A RCCB provides residual-current protection and normally requires coordinated overload and short-circuit protection. A Tipo A RCBO combines those functions. Compare complete installed cost rather than unit price alone.
Two-pole products are common in single-phase circuits. Four-pole products are used in suitable three-phase and neutral arrangements. The required switching and isolation must follow the installation design and local rules.
In and IΔn describe different characteristics. A 63 A / 30 mA RCCB carries a rated current of 63 A and has a rated residual operating current of 30 mA. Higher In does not mean greater leakage sensitivity.
A low quotation can exclude independent testing, model-specific certification or batch inspection. Ask whether the certificate covers the precise electrical rating and construction being purchased.
Sample orders carry high unit freight and handling costs. Distributor orders can reduce unit cost through carton quantities, planned production and standard packaging. Custom boxes, manuals and labels add setup costs.
A Spanish warehouse price may include stockholding, local support and fast delivery. A factory quotation may be lower before freight, duty, VAT, customs clearance and local inventory costs. Compare landed cost on the same Incoterm.
Logo printing, custom colours, packaging, barcodes, documentation languages and exclusive models affect minimum order quantity and lead time. Confirm whether tooling or compliance updates are included.
| Source | Vantagens | Trade-offs | Best fit |
|---|---|---|---|
| Spanish electrical distributor | Fast delivery, local invoicing and returns | Higher unit price and limited customisation | Installers and urgent small orders |
| Established European brand channel | Known specification system and broad support | Premium pricing and channel restrictions | Specified projects and standardised portfolios |
| Direct manufacturer | OEM options, project pricing and product access | Buyer manages qualification, import and inventory | Distributors, wholesalers and repeat volume |
| Marketplace or unknown trader | Easy comparison and small quantities | Certificate, traceability and after-sales risk | Samples only after careful verification |
Type A RCDs are widely used with appliances and electronic equipment that can produce sinusoidal AC and pulsating DC residual currents. They may be appropriate for many residential and commercial circuits, subject to equipment instructions and national rules.
| Aplicativo | Selection note |
|---|---|
| General household appliances | Type A is often considered for loads containing single-phase electronic circuits |
| Variable-speed appliances | Check whether Type A or Type F is required by the manufacturer |
| Carregamento de veículos elétricos | Type A/F may require a compliant 6 mA RDC-DD; otherwise Type B may be required |
| Inversor fotovoltaico | Use the inverter manufacturer’s specified RCD type; Type B is not universally required or universally avoidable |
| Industrial drive | Waveform and frequency content can require Type F, Type B or another protection arrangement |
Sending this information produces a faster and more comparable quotation than asking only for the “best Type A RCD Spain price.”
The price depends on whether it is an RCCB or RCBO, poles, ratings, brand, certification, quantity, VAT and delivery terms. Use online ranges only for early budgeting and request a current model-specific quotation.
No blanket rule should be assumed. Spain’s REBT and technical guidance recognise several RCD types. The circuit, load waveform, equipment instructions, UNE/HD standards and project requirements determine the suitable type.
CE marking is part of market compliance, but a professional buyer should also check the EU Declaration of Conformity, exact product standard, model traceability and any tender-specific certification.
An RCCB provides residual-current protection and needs coordinated overcurrent protection. An RCBO also protects against overload and short circuit.
Follow the charger instructions and applicable rules. Type A or F with compliant 6 mA DC detection may be permitted; equipment without suitable DC detection can require Type B.
Origin alone does not determine compliance. Verify the exact model, applicable EU requirements, declaration, test evidence, traceability, importer responsibilities and project specifications.