VRL11 RCBO - monopolar + neutro (1P+N) 5-40A

  • rcbo de polo único (1P+N) modular RCBO for single-phase branches, Em 5-40A, curvas B/C.

  • Tipo AC / Tipo A, sensibilidades IΔn 6 / 10 / 30 / 100 / 300 mA; Icn 10 kA @ 240 V / 15 kA @ 120 V.

  • IEC/EN 61009-1 compliant; certified SEMKO / UKCA / CE / SAA.

Obter uma cotação

Categoria:

rcbo polo único VRL11 integrates residual-current and overcurrent protection in a compact 1P+N footprint for single-phase boards, covering 5–40 A with Type AC/A residual protection and B/C tripping curves.

Visão geral

VRL11 is designed for residential and commercial distribution branches where reliable
RCD + MCB functionality is required in minimal space. It supports 240 V and 120 V grids
with high breaking capacities (10 kA @ 240 V; 15 kA @ 120 V), multiple residual
sensitivities from 6 mA to 300 mA, and curve B/C options to coordinate with upstream devices.

Principais recursos

  • Fator de forma: 1P+N (single-pole + neutral), modular DIN-rail
  • Corrente nominal (In): 5-40 A
  • Tensão nominal (Ue): 240 V CA / AC 120 V, 50/60 Hz
  • Tipo de corrente residual: Tipo AC / Tipo A
  • Sensibilidade (IΔn): 6 / 10 / 30 / 100 / 300 mA
  • Curvas de tropeço: B (3-5×In), C (5-10×In)
  • Capacidade de ruptura (Icn): 10 kA @ 240 V; 15 kA @ 120 V
  • Front test button (T); front wiring; compact installation depth
  • Compliance & certification: IEC/EN 61009-1; SEMKO, UKCA, CE, SAA

RCBO Single Pole Technical Data — VRL11

ParâmetroVRL11
Postes1P+N (monopolar + neutro)
Corrente nominal (In)5-40 A
Tensão nominal (Ue)AC 240 V / AC 120 V
Frequência50/60 Hz
Tipo de corrente residualTipo AC / Tipo A
Corrente residual nominal (IΔn)6 / 10 / 30 / 100 / 300 mA
Curva de disparo do MCBB: 3-5 × In; C: 5-10 × In
Capacidade de ruptura (Icn)10 kA @ 240 V; 15 kA @ 120 V
InstalaçãoTrilho DIN; fiação frontal; botão de teste (T)
Uso recomendadoResidential & commercial lighting/socket branches up to 40 A
PadrõesIEC/EN 61009-1
CertificaçõesSEMKO, UKCA, CE, SAA

Aplicativos

  • Apartments & houses: lighting and socket circuits (≤ 40 A)
  • Commercial offices & retail: small-load branches
  • Public facilities: admin rooms, classrooms, auxiliary circuits

Downloads e imagens

rcbo single pole VRL11 1P+N, 5–40A, Type AC/A, IΔn 6/10/30/100/300 mA, Icn 10 kA @240 V / 15 kA @120 V

Padrões e conformidade

Conforms to IEC/EN 61009-1. Certified by SEMKO, UKCA, CE, SAA.
Always coordinate with upstream devices and follow local codes for selectivity and fault levels.

PERGUNTAS FREQUENTES

What distinguishes VRL11 from other 1P+N RCBOs?

VRL11 targets 5–40 A single-phase circuits on both 240 V and 120 V grids with high Icn (10 kA / 15 kA), Type AC/A residual protection and curve B/C options.

Which sensitivity (IΔn) is typical for sockets and lighting?

30 mA is most common; 6–10 mA for higher touch-safety; 100–300 mA per coordination and code requirements.

How do I choose between curve B and curve C?

Use B (3–5×In) for resistive/lightly inductive loads; use C (5–10×In) for higher inrush (motors, transformers). Verify discrimination with upstream protection.