VRL22 RCBO — 2P / 4P, 6–63A (AC/A/ASi, Type B/B+, EV Type A/F)

  • 2 pole rcbo / 4-pole platform covering 6–63A, B/C curves, 240/415 V, 50/60 Hz.

  • Residual options: Type AC / Type A / ASi; Type B / B+ variant; EV variants (VRL22A EV, VRL22F EV)와 함께 6 mA DC detection.

  • Standards & certifications: IEC/EN 61009-1, IEC/EN 62423 (Type B), IEC 62955 (EV RDC-PD), VDE 0664-400; SEMKO / UKCA / CE / SAA.

견적 받기

카테고리:

2 pole rcbo VRL22 is a versatile RCBO platform available in 2P and 4P configurations, rated 6–63 A for 240/415 V, 50/60 Hz systems. The family spans Type AC/A/ASi, advanced Type B / B+ variants for smooth DC and high-frequency residuals, and EV-focused models (VRL22A EV / VRL22F EV) with 6 mA DC detection per IEC 62955 (RDC-PD).

개요

VRL22 integrates overload, short-circuit and residual-current protection into a single device for
single- and three-phase boards. The platform supports selective coordination through B/C curves and
multiple sensitivities, while its variant family addresses special waveforms (VFDs, PV inverters, EVSE).
2P targets single-phase lines at 240 V; 4P targets three-phase at 415 V, with shared current range up to 63 A.

주요 기능

  • Poles: 2P (single-phase) and 4P (three-phase)
  • Rated current (In): 6–63 A
  • Rated voltage (Ue): AC 240 V (2P) / AC 415 V (4P), 50/60 Hz
  • Residual current options:
    • Type AC / Type A / ASi (platform/base)
    • Type B / B+ variant for smooth DC & high frequency (B+ extended HF coverage)
    • EV variants: VRL22A EV (Type A EV) & VRL22F EV (Type F EV) with 6 mA DC detection
  • Sensitivity (IΔn): platform typical options 30 / 100 / 300 / 500 mA; EV includes 30 mA + RDC-PD 6 mA DC per IEC 62955
  • Tripping curves: B (3–5×In), C (5–10×In)
  • 표준: IEC/EN 61009-1 (platform), IEC/EN 62423 (Type B), IEC 62955 (EV), VDE 0664-400 (B/B+)
  • Certifications: SEMKO, UKCA, CE, SAA
  • DIN-rail mounting; front test button (T); front wiring

2 Pole RCBO Technical Data — VRL22 Platform

매개변수VRL22 (Base: AC/A/ASi)VRL22A EV / VRL22F EVVRL22B / VRL22 B+
2P / 4P2P / 4P2P / 4P
Rated current (In)6–63 A6–63 A6–63 A
Rated voltage (Ue)2P: AC 240 V; 4P: AC 415 V2P: AC 240 V; 4P: AC 415 V2P: AC 240 V; 4P: AC 415 V
빈도50/60 Hz
Residual current typeType AC / Type A / ASiType A EV / Type F EV (with 6 mA DC RDC-PD)Type B / B+ (smooth DC & high frequency)
Rated residual current (IΔn)30 / 100 / 300 / 500 mA (typical)30 mA AC + 6 mA DC detection (RDC-PD)30 / 100 / 300 / 500 mA (typical)
HF/DC responseAC & pulsating DC (ASi improves immunity)AC + pulsating DC + smooth DC ≥ 6 mA (EV)B: up to ~1 kHz; B+: extended up to ~20 kHz
MCB tripping curveB (3–5×In) / C (5–10×In)
규정 준수IEC/EN 61009-1IEC/EN 61009-1; IEC 62955 (RDC-PD)IEC/EN 61009-1; IEC/EN 62423; VDE 0664-400
인증SEMKO, UKCA, CE, SAAUKCA, CE, SAA (region-specific)CE/UKCA; region-specific
설치DIN-rail; front wiring; front test button (T)
Recommended useGeneral distribution (residential/commercial)EVSE & EV charging circuits (AC + 6 mA DC)VFD-driven loads, PV inverters, medical/lab gear

Notes: exact option sets (IΔn, curves, approvals) may vary by region and sub-model. Check the model code & datasheet for your market.

애플리케이션

  • Residential & commercial distribution boards (2P at 240 V)
  • Three-phase panels and feeders (4P at 415 V)
  • EV charging: wallboxes, AC EVSE (VRL22A EV / VRL22F EV)
  • VFD/drive systems, PV inverters, UPS and SMPS (Type B / B+)

Downloads & Images

2 pole rcbo VRL22 2P/4P, 6–63A, Type AC/A/ASi, Type B/B+, EV (VRL22A EV / VRL22F EV) with 6 mA DC detection

표준 및 규정 준수

Platform: IEC/EN 61009-1. Type B: IEC/EN 62423, VDE 0664-400.
EV variants: IEC 62955 (RDC-PD 6 mA DC). Certifications include
SEMKO, UKCA, CE, SAA (availability per region).

자주 묻는 질문

What is the difference between VRL22 base, VRL22B/B+ and EV models?

Base covers Type AC/A/ASi for common loads. VRL22B/B+ detects smooth DC and higher-frequency leakage for VFD/PV/medical loads. VRL22A EV / VRL22F EV add 6 mA DC detection per IEC 62955 for AC EV charging.

When should I choose 4P instead of 2P?

사용 4P on three-phase systems (415 V) or when neutral switching/isolation is required. 2P fits single-phase (240 V) circuits.

Type B vs Type A — which one do I need?

유형 A detects AC + pulsating DC and suits most electronic loads. 유형 B (and B+) is required for smooth DC and high-frequency leakage typical of VFDs, PV inverters or certain medical equipment.

How do EV variants meet DC leakage requirements?

EV models integrate RDC-PD functionality (IEC 62955), providing 6 mA DC detection in addition to 30 mA AC residual protection to comply with EVSE standards.

상품평

아직 상품평이 없습니다.

“VRL22 RCBO — 2P / 4P, 6–63A (AC/A/ASi, Type B/B+, EV Type A/F)”의 첫 상품평을 남겨주세요

이메일 주소는 공개되지 않습니다. 필수 필드는 *로 표시됩니다