KY-40/G2000 DC 서지 보호 장치(유형 2, 2000V)

  • 그리고 2000V DC SPD KY-40/G2000 provides Type 2 surge protection for ultra-high voltage PV systems.
  • Designed for HVDC feeders, utility-scale solar plants, and specialized industrial photovoltaic installations.
  • IEC 61643-31 certified, DIN-rail mount, with shared T2 wiring and dimension diagrams.
견적 받기

카테고리:

개요

그리고 2000V DC SPD KY-40/G2000 is a Type 2 surge protective device 설계 대상
ultra-high voltage photovoltaic systems. It ensures robust surge protection for
PV 컴바이너 박스, 인버터 DC 단자 및 DC 피더의
2000VDC utility-scale plants. This model is widely used in HVDC transmission-based solar projects
and specialized industrial applications where 2000V arrays are deployed. Fully compliant with
IEC 61643-31, CE, UKCA 및 RoHS.

주요 기능

  • 2000V DC SPD Type 2 device for ultra-high voltage PV and HVDC feeders.
  • Engineered for utility-scale and industrial PV systems operating at 2000VDC.
  • High surge handling capability with replaceable cartridges and visible status indicators.
  • Optional NO/NC alarm contacts support remote monitoring across large plants.
  • Part of the KY T2 surge protection series, ensuring compatibility with fuses and disconnectors.

사양

유형유형 2(T2)
시스템 전압(Ucpv)2000 V DC
공칭 방전 전류(In)20 kA
최대 방전 전류(I최대)40 kA
전압 보호 수준(Up)≤ 6.0 kV
응답 시간(ta)< 25ns
PV 단락 회로 내성(Iscpv)20 kA
보호 모드 / 토폴로지U 유형
알람 연락처(선택 사항)220V, 0.5A, NO/NC
권장 업스트림 퓨즈LS7-50k(데이터시트 기준)
배선/단자6-35mm² 나사 단자
마운팅35mm DIN 레일
인클로저 / 가연성플라스틱 하우징, UL94-V0
작동 조건-40℃ ~ +70℃; ≤95% rh
치수(W×H×D)36 × 83 × 67mm
표준 및 규정 준수IEC 61643-31:2018, GB/T 18802.31, CE, UKCA, RoHS

배선 및 치수

Wiring diagram of 2000v dc spd KY-40/G2000 Type 2 surge protective device for solar photovoltaic systems
KY T2 시리즈(600V/1000V/1500V/2000V)의 공유 배선도입니다.
Dimension drawing of 2000v dc spd KY-40/G2000 Type 2 surge protective device for PV combiner box protection
KY T2 시리즈용 공유 치수 도면.

애플리케이션

  • Utility-scale PV plants with 2000VDC arrays and central inverters.
  • High-voltage DC feeders in HVDC-based solar projects.
  • Special industrial photovoltaic installations requiring ultra-high voltage SPD protection.

자주 묻는 질문

Q1. Why is a 2000V DC SPD necessary in PV systems?

As PV systems evolve towards ultra-high voltage arrays, a 2000V SPD ensures equipment protection and compliance with international standards.

Q2. What are the main applications of KY-40/G2000?

It is widely used in utility-scale solar farms, HVDC feeders, and specialized industrial PV systems with 2000V strings.

Q3. Can KY-40/G2000 work with monitoring systems?

Yes. The optional NO/NC alarm contacts allow remote monitoring and integration with SCADA in large solar farms.

Q4. Which certifications does KY-40/G2000 meet?

IEC 61643-31, GB/T 18802.31, CE, UKCA, and RoHS certifications are included.

Request a Quote for 2000v dc spd KY-40/G2000

상품평

아직 상품평이 없습니다.

“KY-40/G2000 DC Surge Protective Device (Type 2, 2000V)”의 첫 상품평을 남겨주세요

이메일 주소는 공개되지 않습니다. 필수 필드는 *로 표시됩니다