KY-40/G1500 DC 서지 보호 장치(유형 2, 1500V)

  • 그리고 1500V DC SPD KY-40/G1500 provides advanced Type 2 surge protection for modern PV systems.
  • Designed for utility-scale solar plants, central inverters, and large PV combiner boxes operating at 1500VDC.
  • IEC 61643-31 certified, DIN-rail design, shared wiring and dimension diagrams with KY T2 series.
견적 받기

카테고리:

개요

그리고 1500V DC SPD KY-40/G1500 is a Type 2 surge protective device optimized for
high-voltage photovoltaic installations. With support for 1500VDC arrays, it ensures reliable surge
suppression for PV 컴바이너 박스, inverter DC inputs, and DC feeders in
utility-scale solar farms. This model is the preferred choice for large projects where efficiency and safety at
higher system voltages are critical. Compliant with
IEC 61643-31, CE, UKCA 및 RoHS.

주요 기능

  • 1500V DC SPD Type 2 protection for large PV arrays, central inverters, and high-voltage combiner boxes.
  • Enhanced discharge capacity to meet the needs of utility-scale and ground-mounted PV plants.
  • Modular replaceable cartridges with visible indicator for maintenance.
  • Remote alarm contacts (NO/NC) available, enabling monitoring in large PV installations.
  • Part of the KY T2 surge protection series, designed for seamless integration with fuses and disconnectors.

사양

유형유형 2(T2)
시스템 전압(Ucpv)1500V DC
공칭 방전 전류(In)20 kA
최대 방전 전류(I최대)40 kA
전압 보호 수준(Up)≤ 5.0 kV
응답 시간(ta)< 25ns
PV 단락 회로 내성(Iscpv)20 kA
보호 모드 / 토폴로지U 유형
알람 연락처(선택 사항)220V, 0.5A, NO/NC
권장 업스트림 퓨즈LS7-50k(데이터시트 기준)
배선/단자6-35mm² 나사 단자
마운팅35mm DIN 레일
인클로저 / 가연성플라스틱 하우징, UL94-V0
작동 조건-40℃ ~ +70℃; ≤95% rh
치수(W×H×D)36 × 83 × 67mm
표준 및 규정 준수IEC 61643-31:2018, GB/T 18802.31, CE, UKCA, RoHS

배선 및 치수

Wiring diagram of 1500v dc spd KY-40/G1500 Type 2 surge protective device for solar photovoltaic systems
KY T2 시리즈(600V/1000V/1500V/2000V)의 공유 배선도입니다.
Dimension drawing of 1500v dc spd KY-40/G1500 Type 2 surge protective device for PV combiner box protection
KY T2 시리즈용 공유 치수 도면.

애플리케이션

  • Utility-scale solar plants and ground-mounted PV farms designed with 1500V arrays.
  • Central and string inverters operating at 1500VDC inputs.
  • Large-scale PV combiner boxes requiring stable Type 2 surge protection.

자주 묻는 질문

Q1. What makes the 1500V DC SPD KY-40/G1500 suitable for large PV plants?

It supports 1500V systems and offers high surge capacity, making it ideal for utility-scale PV farms and centralized inverters.

Q2. Can KY-40/G1500 be integrated with central inverters?

Yes. It is specifically designed to protect inverter DC inputs and feeders at 1500VDC.

Q3. Does the KY-40/G1500 include alarm contacts?

Yes. Optional NO/NC alarm terminals are available, allowing remote monitoring in large PV projects.

Q4. Which certifications does KY-40/G1500 comply with?

IEC 61643-31, GB/T 18802.31, CE, UKCA, and RoHS certifications are included.

Request a Quote for 1500v dc spd KY-40/G1500

상품평

아직 상품평이 없습니다.

“KY-40/G1500 DC Surge Protective Device (Type 2, 1500V)”의 첫 상품평을 남겨주세요

이메일 주소는 공개되지 않습니다. 필수 필드는 *로 표시됩니다