VFL005 회로 차단기 RCCB 유형 - 2P 및 4P 잔류 전류 보호

  • Circuit breaker RCCB type for reliable residual current protection in residential and industrial systems

  • Available in 2 pole & 4 pole versions, rated current options 16A to 100A, sensitivity from 30mA to 300mA

  • Compliant with IEC/EN 61008-1, featuring high short-circuit withstand capacity and compact installation

견적 받기

카테고리:

개요

그리고 VFL005 circuit breaker RCCB type provides effective protection against leakage current, electric shocks,
and fire hazards caused by ground faults. Designed with 2P and 4P configurations, it ensures reliable safety in both
residential and commercial installations. The unit complies with IEC/EN 61008-1 standards.

주요 기능

  • 2P and 4P residual current circuit breaker with rated currents from 16A to 100A
  • Sensitivity options: 30mA, 100mA, 300mA for flexible protection levels
  • Rated voltage: 2P up to 240V, 4P up to 415V
  • Short-circuit withstand capacity up to 10kA
  • High surge immunity up to 6kV
  • Test button for functional verification
  • Terminal protection degree: IP20
  • Operating temperature: −25°C to +55°C

Technical Data

표준IEC/EN 61008-1
2P, 4P
Rated Current In16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Sensitivity IΔn30mA, 100mA, 300mA
Rated Voltage Ue2P: 240V / 4P: 415V
정격 주파수50/60Hz
Short-Circuit Capacity10kA
Impulse Withstand Voltage6kV
Terminal Size for Cable25–35 mm²
Terminal ProtectionIP20
Mechanical Life≥ 2000 operations
Electrical Life≥ 2000 operations
마운팅DIN rail EN 60715 (35mm)

애플리케이션

The VFL005 circuit breaker RCCB type is suitable for residential, commercial, and industrial distribution systems.
Common applications include:

  • 2 pole RCCB for single-phase home distribution boards
  • 4 pole RCCB for three-phase industrial panels
  • Protection in offices, data centers, and critical facilities
  • Integration with other devices such as DC SPD,
    DC 퓨즈Miniature Circuit Breakers

인증

  • IEC/EN 61008-1 compliance
  • CE certified
  • UKCA compliant
  • RoHS directive

자주 묻는 질문

What is the difference between a 2P and 4P RCCB?

2P RCCBs are used in single-phase systems, while 4P RCCBs are designed for three-phase systems. The choice depends on the type of installation.

Does the VFL005 circuit breaker RCCB type protect against overload?

No, RCCBs are intended for residual current (earth leakage) protection. Overcurrent and short-circuit protection require an MCB or MCCB in combination.

What are the available rated currents for VFL005?

The VFL005 supports 16A, 25A, 32A, 40A, 63A, 80A, and 100A configurations.