VRL11 RCBO - 단극 + 중성(1P+N) 5-40A

  • rcbo single pole (1P+N) modular RCBO for single-phase branches, In 5–40A, curves B/C.

  • Type AC / Type A, sensitivities IΔn 6 / 10 / 30 / 100 / 300 mA; Icn 10 kA @ 240 V / 15 kA @ 120 V.

  • IEC/EN 61009-1 compliant; certified SEMKO / UKCA / CE / SAA.

견적 받기

카테고리:

RCBO 싱글 폴 VRL11 integrates residual-current and overcurrent protection in a compact 1P+N footprint for single-phase boards, covering 5–40 A with Type AC/A residual protection and B/C tripping curves.

개요

VRL11 is designed for residential and commercial distribution branches where reliable
RCD + MCB functionality is required in minimal space. It supports 240 V and 120 V grids
with high breaking capacities (10 kA @ 240 V; 15 kA @ 120 V), multiple residual
sensitivities from 6 mA to 300 mA, and curve B/C options to coordinate with upstream devices.

주요 기능

  • Form factor: 1P+N (single-pole + neutral), modular DIN-rail
  • Rated current (In): 5–40 A
  • Rated voltage (Ue): AC 240 V / AC 120 V, 50/60 Hz
  • Residual current type: Type AC / Type A
  • 감도(IΔn): 6 / 10 / 30 / 100 / 300 mA
  • Tripping curves: B (3–5×In), C (5–10×In)
  • Breaking capacity (Icn): 10 kA @ 240 V; 15 kA @ 120 V
  • Front test button (T); front wiring; compact installation depth
  • Compliance & certification: IEC/EN 61009-1; SEMKO, UKCA, CE, SAA

RCBO Single Pole Technical Data — VRL11

매개변수VRL11
1P+N (single-pole + neutral)
Rated current (In)5–40 A
Rated voltage (Ue)AC 240 V / AC 120 V
빈도50/60 Hz
Residual current typeType AC / Type A
Rated residual current (IΔn)6 / 10 / 30 / 100 / 300 mA
MCB tripping curveB: 3–5 × In; C: 5–10 × In
Breaking capacity (Icn)10 kA @ 240 V; 15 kA @ 120 V
설치DIN-rail; front wiring; test button (T)
Recommended useResidential & commercial lighting/socket branches up to 40 A
표준IEC/EN 61009-1
인증SEMKO, UKCA, CE, SAA

애플리케이션

  • Apartments & houses: lighting and socket circuits (≤ 40 A)
  • Commercial offices & retail: small-load branches
  • Public facilities: admin rooms, classrooms, auxiliary circuits

Downloads & Images

rcbo single pole VRL11 1P+N, 5–40A, Type AC/A, IΔn 6/10/30/100/300 mA, Icn 10 kA @240 V / 15 kA @120 V

표준 및 규정 준수

Conforms to IEC/EN 61009-1. Certified by SEMKO, UKCA, CE, SAA.
Always coordinate with upstream devices and follow local codes for selectivity and fault levels.

자주 묻는 질문

What distinguishes VRL11 from other 1P+N RCBOs?

VRL11 targets 5–40 A single-phase circuits on both 240 V and 120 V grids with high Icn (10 kA / 15 kA), Type AC/A residual protection and curve B/C options.

Which sensitivity (IΔn) is typical for sockets and lighting?

30 mA is most common; 6–10 mA for higher touch-safety; 100–300 mA per coordination and code requirements.

How do I choose between curve B and curve C?

Use B (3–5×In) for resistive/lightly inductive loads; use C (5–10×In) for higher inrush (motors, transformers). Verify discrimination with upstream protection.