240V Surge Protection Device KYSPD-25T1-3+1 | Kuangya

  • Four-pole 240v surge protection device (3+1) design for TN-S and TT systems.

  • Withstands Iimp 25 kA (10/350 μs) per pole, In 25 kA, Imax 100 kA.

  • Pluggable cartridge with indicator window; optional RC contacts; DIN rail mount.

견적 받기

카테고리:
The Kuangya KYSPD-25T1-3+1 is a four-pole 240v surge protection device designed for electrical panels in 230/400 V AC systems. With its 3+1 configuration, it provides enhanced protection for phase-to-neutral and neutral-to-earth paths. This 240v surge protection device is tested according to IEC/EN 61643-11 and withstands lightning currents up to Iimp 25 kA per pole (10/350 μs). It is ideal for service entrance installations where reliable first-stage protection is required.

주요 기능

  • Complies with IEC/EN 61643-11, Class I / Type 1.
  • 3+1 configuration: three phases plus neutral-to-earth protection.
  • Iimp 25 kA (10/350 μs) per pole; In 25 kA; Imax 100 kA.
  • Nominal system voltage Uo/Un: 230/400 V AC; suitable as a 240v surge protection device.
  • Uc options: 320 / 385 / 440 V AC; voltage protection level (Up): ~1.6–2.0 kV.
  • Response time < 25 ns.
  • Pluggable replaceable cartridge with thermal disconnector and visual indicator.
  • Optional RC contacts for remote signaling.
  • Housing UL94 V-0 thermoplastic; IP20 built-in; DIN 35 mm rail mounting.

사양

매개변수Value
제품 코드KYSPD-25T1-3+1
카테고리240V Surge Protection Device (Type 1 / Class I)
Nominal System Voltage (Uo/Un)230 / 400 V AC
Max. Continuous Operating Voltage (Uc)320 / 385 / 440 V AC
공칭 방전 전류(In, 8/20 μs)25 kA
Max. Discharge Current (Imax, 8/20 μs)100 kA
Impulse Discharge Current (Iimp, 10/350 μs)25 kA per pole
전압 보호 수준(상향)~1.6–2.0 kV
응답 시간< 25ns
단락 전류 정격(ISCCR)50 kA
Backup Fuse (max)315 A gL/gG
작동 온도-40 °C … +70 °C
마운팅35 mm DIN rail (EN 60715)
EnclosureThermoplastic, UL94 V-0
Protection DegreeIP20 (built-in)
Remote SignalingOptional RC contacts
표준IEC 61643-11 / EN 61643-11

This 240v surge protection device is recommended for TN-S and TT earthing systems, delivering reliable first-stage lightning current handling.

배선 및 치수

  • Connection diagram: kyspd-25t1-3+1-connection
  • 240v surge protection device 3+1 wiring diagram
  • Dimensions: kyspd-25t1-3+1-dimensions
  • 240v surge protection device 3+1 dimensions

애플리케이션

  • Service entrance protection for low-voltage panels.
  • First-stage 240v surge protection device in coordinated systems with Type 2 and Type 3 SPDs.
  • Commercial and industrial electrical panels requiring robust lightning protection.

자주 묻는 질문

Where should KYSPD-25T1-3+1 be installed?

It should be installed at the service entrance or main panel as a 240v surge protection device.

What is the impulse discharge current rating?

그리고 240v surge protection device withstands Iimp 25 kA per pole (10/350 μs).

Can this device be used in TT systems?

Yes, the 3+1 design makes it suitable for TT as well as TN-S systems.

How can the module be replaced?

The pluggable cartridge design makes this 240v surge protection device easy to service.

Does it support remote monitoring?

예, 원격 시그널링을 위해 옵션으로 RC 터미널을 사용할 수 있습니다.

What standards does it comply with?

IEC/EN 61643-11 for AC surge protective devices.

견적 받기 · Related products: AC MCB, 수동 전송 스위치

상품평

아직 상품평이 없습니다.

“240V Surge Protection Device KYSPD-25T1-3+1 | Kuangya”의 첫 상품평을 남겨주세요

이메일 주소는 공개되지 않습니다. 필수 필드는 *로 표시됩니다