AC Surge Protection Device KYSPD-25T1-3P | Kuangya

  • Three-pole AC 서지 보호 장치 for main distribution boards and service entrance.

  • Impulse current Iimp 25 kA (10/350 μs) per pole, In 25 kA, Imax 100 kA.

  • Pluggable cartridge with status indicator; optional RC contacts; DIN-rail installation.

견적 받기

카테고리:
The Kuangya KYSPD-25T1-3P is a three-pole AC 서지 보호 장치 designed for 230/400 V AC systems. It provides Class I / Type 1 protection against direct lightning currents with an impulse discharge current of 25 kA per pole (10/350 μs). This AC 서지 보호 장치 is ideal for installation at the service entrance as the first stage of a coordinated SPD system.

주요 기능

  • Complies with IEC/EN 61643-11, Category: Class I / Type 1.
  • Three-pole configuration; Iimp 25 kA per pole; In 25 kA; Imax 100 kA.
  • Nominal system voltage Uo/Un: 230/400 V AC.
  • Uc options: 320 / 385 / 440 V AC; voltage protection level (Up): ~1.6–2.0 kV.
  • Fast response time < 25 ns; reliable MOV-based design.
  • Pluggable cartridge with thermal disconnector and visual indicator.
  • Optional RC contacts for remote status signaling.
  • Housing: UL94 V-0 thermoplastic; IP20 built-in; DIN 35 mm rail mount.
  • Trusted as a first-stage AC 서지 보호 장치 for heavy-duty systems.

사양

매개변수Value
제품 코드KYSPD-25T1-3P
카테고리AC Surge Protection Device (Type 1 / Class I)
Nominal System Voltage (Uo/Un)230 / 400 V AC
Max. Continuous Operating Voltage (Uc)320 / 385 / 440 V AC
공칭 방전 전류(In, 8/20 μs)25 kA
Max. Discharge Current (Imax, 8/20 μs)100 kA
Impulse Discharge Current (Iimp, 10/350 μs)25 kA per pole
전압 보호 수준(상향)~1.6–2.0 kV
응답 시간< 25ns
Follow Current Interrupt Rating100 A RMS
단락 전류 정격(ISCCR)50 kA
Backup Fuse (max)315 A gL/gG
작동 온도-40 °C … +70 °C
마운팅35 mm DIN rail (EN 60715)
EnclosureThermoplastic, UL94 V-0
Protection DegreeIP20 (built-in)
Remote SignalingOptional RC contacts
표준IEC 61643-11 / EN 61643-11

This AC 서지 보호 장치 is recommended for use in TN-S, TN-C, and TT systems, ensuring maximum reliability in lightning-prone areas.

배선 및 치수

  • Connection diagram: kyspd-25t1-3p-connection
  • ac surge protection device 3-pole wiring diagram
  • Dimensions: kyspd-25t1-3p-dimensions
  • ac surge protection device 3-pole dimensions

애플리케이션

  • Main distribution boards and service entrances in industrial facilities.
  • First-stage AC 서지 보호 장치 in coordinated SPD systems with Type 2 and Type 3 devices.
  • Commercial buildings requiring reliable lightning current handling.

자주 묻는 질문

Where should KYSPD-25T1-3P be installed?

It should be installed at the service entrance or main distribution board as the first-stage AC 서지 보호 장치.

What is the discharge current rating?

The device withstands Iimp 25 kA per pole, In 25 kA, and Imax 100 kA.

Does it support different earthing systems?

Yes, it is suitable for TN-S, TN-C, and TT systems.

Can the module be replaced?

Yes, the pluggable cartridge makes this AC 서지 보호 장치 easy to service and maintain.

Is remote signaling available?

Yes, optional RC contacts allow integration with monitoring systems.

What standards does it comply with?

IEC/EN 61643-11 standards for AC surge protective devices.

견적 받기 · Related products: AC MCB, 수동 전송 스위치