RCBO VAL003 / VAL003N - 過電流保護付き単極+N型残留電流ブレーカ

  • rcbo single pole (1P+N) for residential & commercial circuits, In 5–40A, curves B/C.

  • タイプAC / タイプA, sensitivities 6 / 10 / 30 / 100 / 300 mA; Icn up to 10 kA @240V (VAL003) / 15 kA @120V (VAL003N).

  • Certified セムコ/UKCA/CE/SAA; electrical & mechanical endurance 2,000 cycles.

お見積もり

カテゴリー:

RCBOシングルポール VAL003 / VAL003N delivers combined residual-current and overcurrent protection in a compact 1P+N form factor (5–40 A), with Type AC/A, multiple IΔn options and B/C curves for residential and commercial circuits.

概要

VAL003 and VAL003N are compact modular RCBOs designed to provide combined protection against overload, short-circuit and residual current faults on single-phase distribution branches. Both variants share the same compact 1P+N footprint and current range (5–40 A), while their rated voltage and breaking capacity differ to fit regional grids: VAL003 targets 240 V systems (up to 10 kA Icn), and VAL003N targets 120 V systems (up to 15 kA Icn). With selectable residual current types (AC / A) and multiple sensitivities (6 / 10 / 30 / 100 / 300 mA), the series suits residential, commercial and light industrial applications where space efficiency and reliable nuisance-trip control are required.

主な特徴

  • フォームファクター: 1P+N (single-pole + neutral), compact modular width
  • 定格電流(In): 5–40 A (typical steps: 5/6/10/16/20/25/32/40 A)
  • 残留電流タイプ: タイプAC / タイプA
  • Sensitivity options (IΔn): 6 / 10 / 30 / 100 / 300 mA
  • Tripping curves: B (3–5×In) そして C (5–10×In)
  • 破断能力(Icn): up to 10 kA @ 240 V (VAL003); 15 kA @ 120 V (VAL003N)
  • Service life: electrical 2,000 cycles / mechanical 2,000 cycles
  • Front test button (T) for routine residual function verification
  • Standards & compliance: IEC/EN 61009-1; certifications SEMKO / UKCA / CE / SAA

RCBO Single Pole Technical Data (VAL003 / VAL003N)

パラメータVAL003VAL003N
ポール1P+N (single-pole + neutral)
定格電流 (In)5–40 A5–40 A
定格電圧 (Ue)AC 240 VAC 120 V
頻度50/60 Hz
残留電流タイプタイプAC / タイプA
定格残留電流 (IΔn)6 / 10 / 30 / 100 / 300 mA
Tripping characteristic (MCB curve)B: 3–5 × In; C: 5–10 × In
破断容量(Icn)4.5 / 6 / 10 kA @ 240 V15 kA @ 120 V
持久力Electrical: 2,000 cycles; Mechanical: 2,000 cycles
規格IEC/EN 61009-1
認証SAMKO、UKCA、CE、SAA
インストールDIN-rail mounting; front wiring; test button (T)
Recommended applicationsResidential branch circuits, commercial lighting & sockets, small equipment feeds

アプリケーション

  • Residential distribution boards: lighting, socket circuits
  • Commercial offices & retail: small loads and outlets
  • Public facilities: classrooms, small rooms, admin areas
  • Light industrial auxiliaries where 1P+N and In ≤ 40 A are sufficient

Certifications & Compliance

Conforms to IEC/EN 61009-1, with certifications SEMKO, UKCA, CE, and SAA.
Refer to local codes for coordination and selectivity with upstream protective devices.

よくあるご質問

What is the difference between VAL003 and VAL003N?

They share the same 1P+N form factor and current range (5–40 A) and support both Type AC and Type A residual protections. VAL003 targets 240 V grids with up to 10 kA Icn; VAL003N targets 120 V grids with 15 kA Icn.

Which sensitivities (IΔn) are available?

6 / 10 / 30 / 100 / 300 mA. For typical socket and lighting circuits, 30 mA is most common; 6–10 mA may be used for higher touch-safety requirements; 100–300 mA are generally for special coordination scenarios per local codes.

How do I choose between curve B and curve C?

Use curve B (3–5×In) for resistive/lightly inductive loads; use curve C (5–10×In) for circuits with higher inrush (e.g., motors, transformers). Always verify with upstream protection and local standards.

Can it be used in light industrial panels?

Yes, within its ratings (1P+N, up to 40 A). For larger currents, three-phase systems, or special waveforms (e.g., EV / Type B), choose other series models accordingly.

レビュー

レビューはまだありません。

“RCBO VAL003 / VAL003N — Single-Pole+N Residual Current Breaker with Overcurrent Protection” の口コミを投稿します

メールアドレスが公開されることはありません。 が付いている欄は必須項目です