第一種サージ防護デバイス KYSPD-25T1-1P|Kuangya

  • Class I / Type 1 SPD for service entrance, 230/400 V AC systems.

  • Impulse current Iimp 25 kA (10/350 μs), In 25 kA, Imax 100 kA.

  • Pluggable module with visual indicator, DIN-rail, optional remote signaling (RC).

お見積もり

カテゴリー:
について 第1種サージ保護装置 KYSPD-25T1-1P is designed for main distribution boards and service entrances. It protects low-voltage AC installations against direct lightning currents and high-energy surges per IEC/EN 61643-11. With an impulse discharge current rating of 25 kA per pole (10/350 μs), it provides robust first-stage protection in coordinated systems.

主な特徴

  • IEC/EN 61643-11、クラスI/タイプ1に準拠。.
  • Impulse discharge current Iimp: 25 kA (10/350 μs); In 25 kA; Imax 100 kA.
  • Uc options: 320 V, 385 V, 440 V AC; nominal system Uo/Un 230/400 V AC.
  • Pluggable cartridge with thermal disconnector and green/red status window.
  • オプションのRC端子により、リモートステータス信号が可能。.
  • Housing UL94 V-0, IP20 (built-in); 35 mm DIN rail mounting.
  • Suitable for TN-S / TN-C / TT systems (correct L-N / N-PE wiring).
  • Ideal as a 第1種サージ保護装置 at the service entrance in coordinated SPD schemes.

仕様

パラメータ価値
商品コードKYSPD-25T1-1P
カテゴリータイプ1/クラスI SPD
公称システム電圧 (Uo/Un)230 / 400 V AC
最大連続使用電圧 (Uc)320 / 385 / 440 V AC
公称放電電流(In、8/20 μs)25 kA
最大放電電流放電電流 (Imax, 8/20 μs)100 kA
インパルス放電電流 (Iimp, 10/350 μs)25kA/極
電圧保護レベル(上)~1.6–2.0 kV (by variant)
応答時間< 25 ns
電流遮断定格に従う100 A RMS
短絡電流定格(ISCCR)50 kA
バックアップヒューズ(最大)315 A gL/gG
動作温度-40 °C ... +70 °C
取り付け35 mm DINレール (EN 60715)
エンクロージャー熱可塑性、UL94 V-0
保護等級IP20(内蔵)
リモート信号オプションのRC接点
規格IEC 61643-11 / EN 61643-11

配線と寸法

  • 接続図: kyspd-25t1-connection
  • SPD-T1-1P-wiring-diagram
  • 寸法: kyspd-25t1-dimensions
  • SPD-T1-1P-Dimension

アプリケーション

  • Service entrance / main distribution (LPZ 0→1) — first stage 第1種サージ保護装置.
  • Industrial & commercial buildings with high lightning exposure.
  • Upstream in coordinated protection with downstream Type 2 / Type 3 SPDs.

よくあるご質問

Where should this SPD be installed?

At the service entrance or main distribution board, as the first protection stage.

Does it support TT and TN systems?

Yes, with proper wiring modes L-N and N-PE.

どのようなバックアップヒューズが必要ですか?

Maximum 315 A gL/gG, as recommended in technical data.

Can it be replaced easily?

Yes, the cartridge is pluggable and field-replaceable.

遠隔監視は可能ですか?

Yes, RC contacts are optional for status signaling.

ISCCRの格付けとは?

50 kA short-circuit withstand capacity.

モジュールが故障したらどうなりますか?

The thermal disconnector isolates it and the indicator turns red.

どのような基準を満たしているのか?

IEC/EN 61643-11 サージ保護デバイス用。.