エレベーター用サージ防護デバイス KYSPD-7T1+2-3P+1|Kuangya

  • Four-pole (3+1) エレベータ用サージ防護装置, protecting both phase and neutral conductors.

  • Iimp 7 kA (10/350 μs) per pole, In 20 kA, Imax 40 kA.

  • Pluggable design with LED status indicator, thermal disconnector, and optional RC remote signaling.

お見積もり

カテゴリー:
The Kuangya KYSPD-7T1+2-3+1 is a specialized four-pole (3+1) エレベータ用サージ防護装置. Elevators and lifts require highly reliable protection against power surges to avoid downtime and costly repairs. This エレベータ用サージ防護装置 combines Type 1 and Type 2 protection in one unit, safely discharging both lightning currents and transient switching surges, ensuring uninterrupted operation of elevator systems.

主な特徴

  • IEC/EN 61643-11に準拠し、クラスIとクラスIIの両方の保護を提供。
  • 3+1 configuration: three-phase plus dedicated neutral-to-earth protection.
  • Iimp 7 kA (10/350 μs) per pole; In 20 kA; Imax 40 kA.
  • Uc: 275 V AC; nominal system voltage: 230/400 V AC.
  • Voltage protection level (Up): ≤ 1.5 kV.
  • Fast response time < 25 ns.
  • Compact pluggable cartridge with thermal disconnector and visual status window.
  • Optional RC contacts for remote status monitoring in elevator control rooms.
  • Housing: UL94 V-0 thermoplastic; IP20 built-in; DIN 35 mm rail mount.
  • 信頼できる エレベータ用サージ防護装置 in residential, commercial, and high-rise buildings.

仕様

パラメータ価値
商品コードkyspd-7t1+2-3+1
カテゴリーSurge Protection Device for Elevators
公称システム電圧AC230/400 V
Max. Continuous Operating Voltage (Uc)275 V AC
Impulse Discharge Current (Iimp, 10/350 μs)7 kA per pole
公称放電電流(In、8/20 μs)20 kA
Max. Discharge Current (Imax, 8/20 μs)40 kA
電圧保護レベル(上)≤ 1.5 kV
応答時間< 25 ns
Backup Fuse (max)125 A gL/gG
短絡電流定格(ISCCR)25 kA
動作温度-40 °C … +70 °C
取り付け35 mm DIN rail (EN 60715)
HousingThermoplastic UL94 V-0
保護等級IP20 (built-in)
Remote SignalingOptional RC contacts
規格IEC/EN 61643-11

これは エレベータ用サージ防護装置 ensures safe and continuous operation of elevator drives, controllers, and communication circuits by eliminating transient overvoltages.

配線と寸法

  • Connection diagram: kyspd-7t1+2-3+1-connection
  • surge protection device for elevators wiring diagram
  • 寸法: kyspd-7t1+2-3+1-dimensions
  • surge protection device for elevators dimensions

アプリケーション

  • Main distribution boards feeding elevator systems.
  • Dedicated エレベータ用サージ防護装置 in residential towers and commercial buildings.
  • Ensures uninterrupted lift operation in high-rise and industrial facilities.

よくあるご質問

Why do elevators need surge protection?

Elevators include sensitive controllers and drives that are vulnerable to overvoltages. A エレベータ用サージ防護装置 prevents damage and downtime.

Where should KYSPD-7T1+2-3+1 be installed?

It should be installed in the distribution board that powers the elevator system.

Does it protect both phase and neutral conductors?

Yes, the 3+1 design makes this エレベータ用サージ防護装置 effective for both phase-to-neutral and neutral-to-earth protection.

Can it be monitored remotely?

Yes, optional RC contacts allow integration into building management systems for elevator monitoring.

どのような基準を満たしているのか?

IEC/EN 61643-11 for surge protective devices.

お見積もり · Related: AC MCB, 手動トランスファースイッチ

レビュー

レビューはまだありません。

“Surge Protection Device for Elevators KYSPD-7T1+2-3P+1 | Kuangya” の口コミを投稿します

メールアドレスが公開されることはありません。 が付いている欄は必須項目です