RCCB VFL002 - 2/4極残留電流サーキットブレーカ

  • RCCB 2ポール for reliable earth-leakage protection in single-phase and three-phase boards (2P/4P range)

  • In: 16–100A; IΔn: 10/30/100/300 mA; Ue: 240 V (2P) / 415 V (4P); Inc=IΔc up to 10 kA; Uimp 6 kV

  • AC / A / ASi options; IEC/EN 61008-1 with NF, ISI, UKCA, CE approvals

お見積もり

カテゴリー:

概要

The Kuangya VFL002 is an RCCB 2ポール (also available as 4 pole) residual current device engineered to
protect people and installations from electric shock and fire risk due to earth-leakage faults. It offers AC, A, and
high-immunity ASi detection classes, making it suitable for residential housing, commercial buildings, and light
industrial facilities. Selection covers rated currents from 16 A to 100 A and sensitivities from 10 mA to 300 mA.

Detection classes & tripping

  • AC class — trips for sinusoidal AC residual currents applied slowly or suddenly.
  • A class — AC plus pulsating DC residual currents.
  • ASi type — high-immunity A type (G/KV + Si behavior); filters transients/harmonics to reduce nuisance tripping.
  • Break time under IΔn (Normal): ≤ 100 ms
  • Short time delay: 10–300 ms (ASi, G, KV types)
  • Selective S type: 150–500 ms

主な特徴

  • Configurations: 2P / 4P with top or bottom supply, any mounting position
  • Rated current In: 16, 25, 32, 40, 63, 80, 100 A
  • Rated sensitivity IΔn: 10 mA (2P/4P 16–40 A), 30 mA, 100 mA, 300 mA
  • Rated voltage Ue: 2P: 240 V~; 4P: 415 V~   |   Ui: 500 V |   fn: 50/60 Hz
  • Rated residual making & breaking (IΔm): 500 A (In 16–40 A); 630 A (63 A); 800 A (80 A); 1000 A (100 A)
  • Inc = IΔc (conditional short-circuit): 6 kA or 10 kA (with upstream SCPD coordination)
  • Impulse withstand Uimp: 6 kV (1.2/50 μs); 誘電テスト: 2.5 kV / 1 min
  • 端子保護: IP20; fault current indicator provided
  • Ambient: −25 °C … +55 °C (daily average ≤ 35 °C); Storage: −40 °C … +70 °C
  • Standards/Approvals: IEC/EN 61008-1; NF, ISI, UKCA, CE

技術データ

スタンダードIEC/EN 61008-1
モデルVFL002
ポール2P、4P
定格電流 (In)16A、25A、32A、40A、63A、80A、100A
定格感度 (IΔn)10 mA (16–40 A), 30 mA, 100 mA, 300 mA
定格電圧 (Ue)2P:240V、4P:415V
絶縁電圧 (Ui)500 V
定格周波数50/60 Hz
Rated residual making & breaking (IΔm)500 A (In = 16–40 A); 630 A (In = 63 A); 800 A (In = 80 A); 1000 A (In = 100 A)
条件付き短絡(Inc = IΔc)6000 A, 10000 A
Waveform sensitivityAC, A, ASi
Tripping time classesInstantaneous / Short time delay (10–300 ms) / Selective S (150–500 ms)
Break time under IΔn (Normal)≤ 100 ms
インパルス耐量(Uimp)6 kV
Dielectric test voltage2.5 kV (1 min at power frequency)
Pollution degree2
Electrical life≥ 2000 operations
Mechanical life≥ 2000 operations
Fault current indicatorYes
端子保護度IP20
Ambient temperature (avg ≤ 35 °C)-25 °C ~ +55 °C
保存温度-40 °C ~ +70 °C
Terminal connectionケーブル / ピン型バスバー
Terminal size (cable, top/bottom)25–35 mm²; 18–3 / 18–2 AWG (per size class)
Terminal size (busbar, top/bottom)10/16 mm²; 18–8 / 18–5 AWG
締め付けトルク2.5 N·m (≈ 22 in-lbs)
取り付けDIN rail EN 60715 (35 mm), fast clip
ConnectionFrom top and bottom
ApprovalsNF, ISI, UKCA, CE

アプリケーション

  • Single-phase boards requiring an RCCB 2ポール device at 240 V~
  • Three-phase distribution using 4P at 415 V~ with coordinated upstream SCPD
  • Loads with electronics and frequent transients — use ASi high-immunity version

認証

準拠 IEC/EN 61008-1; certified NF, ISI, UKCA, CE.

よくあるご質問

When do I choose 2P vs 4P?

Use 2P for single-phase 240 V~ systems and 4P for three-phase 415 V~ systems.

What sensitivity should I select?

10/30 mA for additional personal protection; 100/300 mA for fire protection and selectivity.

How to coordinate conditional short-circuit rating?

Use an upstream breaker/fuse so the installation respects Inc = IΔc (6 kA / 10 kA) under fault conditions.

rccb 2 pole VFL002 Kuangya, 2P/4P 16–100A 10/30/100/300 mA