VDL01 RCBOサーキットブレーカ - 2P/4P 調節可能な残留電流保護(最大90A)

  • rcbo circuit breaker VDL01 with 2P/4P options and adjustable current pairs (5/15A → 60/90A), designed for mains/feeder protection.

  • Normal & Type S (time-delay) residual protection with IΔn 300 mA / 500 mA, coordinated selectivity for upstream devices.

  • Icn 3 kA, 230/240 V & 400/415 V, digital current display, anti-tamper design; built to NF C 61450 / NF C 62411 / IEC 61009.

お見積もり

カテゴリー:

rcbo circuit breaker VDL01 is a two- or four-pole adjustable device combining residual-current and overcurrent protection for mains and feeder circuits, with selectable Normal and Type S (time-delay) characteristics.

概要

VDL01 integrates residual-current and overcurrent protection into a compact 2P/4P form.
It features adjustable current pairs to match upstream/downstream coordination and
offers Normal そして タイプS (time-delay) residual functions with higher
sensitivities (IΔn 300 mA / 500 mA) suitable for main/feeder selectivity.
A digital current display and anti-tamper design improve on-site setting and security.

主な特徴

  • ポール: 2P そして 4P for single- and three-phase systems
  • Adjustable current pairs: 5/15 A, 10/30 A, 15/45 A, 30/60 A, 60/90 A
  • Residual modes: Normal & タイプS (time-delay for selective protection)
  • 感度(IΔn): 300 mA / 500 mA
  • 破断能力(Icn): 3 kA
  • Rated voltage: 230/240 V そして 400/415 V, 50/60 Hz
  • Digital current display; anti-tamper design; temperature-insensitive operation
  • 標準: NF C 61450, NF C 62411, IEC 61009

RCBO Circuit Breaker Technical Data — VDL01

パラメータVDL01 (2P)VDL01 (4P)
ポール2P4P
Adjustable current pairs (A)5/15, 10/30, 15/45, 30/60, 60/90
定格電圧 (Ue)230/240 V400/415 V
頻度50/60 Hz
Residual modeNormal / Type S (time-delay)
定格残留電流 (IΔn)300 mA / 500 mA
破断容量(Icn)3 kA
Indication / InterfaceDigital current display; anti-tamper design
Temperature sensitivityInsensitive (per product note)
規格NF C 61450; NF C 62411; IEC 61009

アプリケーション

  • Mains and feeder circuits requiring selective residual protection (Type S)
  • Commercial and public buildings with coordinated upstream devices
  • Three-phase distribution where 4P selectivity and higher IΔn are needed
  • Panels needing adjustable current pairs for field tuning
 

規格とコンプライアンス

Designed in accordance with NF C 61450, NF C 62411そして IEC 61009. Check local codes for selectivity and discrimination requirements.

よくあるご質問

What does Type S mean on VDL01?

Type S is a time-delay residual function that helps achieve selectivity with downstream RCD/RCBOs, reducing nuisance trips on mains/feeder circuits.

How do the adjustable current pairs work?

You can select among 5/15, 10/30, 15/45, 30/60, and 60/90 A pairs to match the protected feeder and upstream device, using the built-in digital display to verify settings.

When should I choose 4P over 2P?

Use 4P for three-phase systems or when neutral switching and full four-pole isolation are required; 2P fits single-phase feeders.

Which IΔn should I use?

VDL01 offers 300 mA and 500 mA suited for upstream selectivity. Choose per local codes and coordination studies.