240Vサージ保護装置KYSPD-25T1-3+1|Kuangya

  • Four-pole 240Vサージ保護装置 (3+1) design for TN-S and TT systems.

  • Withstands Iimp 25 kA (10/350 μs) per pole, In 25 kA, Imax 100 kA.

  • Pluggable cartridge with indicator window; optional RC contacts; DIN rail mount.

お見積もり

カテゴリー:
The Kuangya KYSPD-25T1-3+1 is a four-pole 240Vサージ保護装置 designed for electrical panels in 230/400 V AC systems. With its 3+1 configuration, it provides enhanced protection for phase-to-neutral and neutral-to-earth paths. This 240Vサージ保護装置 is tested according to IEC/EN 61643-11 and withstands lightning currents up to Iimp 25 kA per pole (10/350 μs). It is ideal for service entrance installations where reliable first-stage protection is required.

主な特徴

  • Complies with IEC/EN 61643-11, Class I / Type 1.
  • 3+1 configuration: three phases plus neutral-to-earth protection.
  • Iimp 25 kA (10/350 μs) per pole; In 25 kA; Imax 100 kA.
  • Nominal system voltage Uo/Un: 230/400 V AC; suitable as a 240Vサージ保護装置.
  • Uc options: 320 / 385 / 440 V AC; voltage protection level (Up): ~1.6–2.0 kV.
  • Response time < 25 ns.
  • Pluggable replaceable cartridge with thermal disconnector and visual indicator.
  • Optional RC contacts for remote signaling.
  • Housing UL94 V-0 thermoplastic; IP20 built-in; DIN 35 mm rail mounting.

仕様

パラメータValue
Product CodeKYSPD-25T1-3+1
Category240V Surge Protection Device (Type 1 / Class I)
Nominal System Voltage (Uo/Un)230 / 400 V AC
Max. Continuous Operating Voltage (Uc)320 / 385 / 440 V AC
Nominal Discharge Current (In, 8/20 μs)25 kA
Max. Discharge Current (Imax, 8/20 μs)100 kA
Impulse Discharge Current (Iimp, 10/350 μs)25 kA per pole
Voltage Protection Level (Up)~1.6–2.0 kV
応答時間< 25 ns
Short-Circuit Current Rating (ISCCR)50 kA
Backup Fuse (max)315 A gL/gG
動作温度-40 °C … +70 °C
取り付け35 mm DIN rail (EN 60715)
EnclosureThermoplastic, UL94 V-0
Protection DegreeIP20 (built-in)
Remote SignalingOptional RC contacts
規格IEC 61643-11 / EN 61643-11

This 240Vサージ保護装置 is recommended for TN-S and TT earthing systems, delivering reliable first-stage lightning current handling.

配線と寸法

  • Connection diagram: kyspd-25t1-3+1-connection
  • 240v surge protection device 3+1 wiring diagram
  • Dimensions: kyspd-25t1-3+1-dimensions
  • 240v surge protection device 3+1 dimensions

アプリケーション

  • Service entrance protection for low-voltage panels.
  • First-stage 240Vサージ保護装置 in coordinated systems with Type 2 and Type 3 SPDs.
  • Commercial and industrial electrical panels requiring robust lightning protection.

よくあるご質問

Where should KYSPD-25T1-3+1 be installed?

It should be installed at the service entrance or main panel as a 240Vサージ保護装置.

What is the impulse discharge current rating?

について 240Vサージ保護装置 withstands Iimp 25 kA per pole (10/350 μs).

Can this device be used in TT systems?

Yes, the 3+1 design makes it suitable for TT as well as TN-S systems.

How can the module be replaced?

The pluggable cartridge design makes this 240Vサージ保護装置 easy to service.

Does it support remote monitoring?

はい、オプションのRC端子でリモート信号が可能です。

What standards does it comply with?

IEC/EN 61643-11 for AC surge protective devices.

お見積もり · Related products: AC MCB, 手動トランスファースイッチ

レビュー

レビューはまだありません。

“240V Surge Protection Device KYSPD-25T1-3+1 | Kuangya” の口コミを投稿します

メールアドレスが公開されることはありません。 が付いている欄は必須項目です