RCCB VKL11F - 残留電流ブレーカ

  • Kuangya VKL11F タイプf rccb for mixed-frequency residual-current protection in single- and three-phase systems

  • 2P/4P, In 16–100 A; IΔn 10/30/100/300 mA; Ue 240 V (2P) / 415 V (4P); Ui 500 V; 50/60 Hz

  • Uimp 4/6 kV; Inc = IΔc 6/10 kA (with upstream SCPD); IP20 terminals; DIN-rail EN 60715

お見積もり

カテゴリー:

概要

The VKL11F タイプf rccb detects earth leakage including mixed-frequency components that commonly
occur with inverters, VFD-driven motors, and UPS equipment. It disconnects the circuit when residual current
exceeds the set threshold to protect people and installations against electric shock and fire hazards.
Available as 2P (single-phase) and 4P (three-phase).

主な特徴

  • ポール: 2P / 4P
  • 定格電流(In): 16, 25, 32, 40, 63, 80, 100 A
  • 定格感度(IΔn): 10 / 30 / 100 / 300 mA
  • 定格電圧 (Ue): 240 V~ (2P) / 415 V~ (4P)
  • 絶縁電圧(Ui): 500 V   |   Frequency: 50/60 Hz
  • 残留とブレーク(IΔm): 500 / 630 / 800 / 1000 A (per In group)
  • Conditional short-circuit current: Inc = IΔc 6 kA / 10 kA (with upstream SCPD)
  • インパルス耐量(Uimp): 4 kV / 6 kV
  • Dielectric test voltage: 2.5 kV for 1 min (power frequency)
  • Tripping behavior: Instantaneous; Short time delay (10–300 ms); Selective S (150–500 ms)
  • Break time under IΔn (Normal): ≤ 100 ms
  • Terminal protection degree: IP20
  • Endurance: ≥ 20,000 mechanical / ≥ 2,000 electrical operations
  • Mounting: DIN rail EN 60715 (35 mm), fast clip

技術データ

モデルVKL11F
スタンダードIEC/EN 61008-1
ポール2P、4P
定格電流 (In)16A、25A、32A、40A、63A、80A、100A
定格感度 (IΔn)10mA、30mA、100mA、300mA
定格電圧 (Ue)2P:240V、4P:415V
絶縁電圧 (Ui)500 V
定格周波数50/60 Hz
残留とブレーク(IΔm)500 A(16-40 A時); 630 A(63 A時); 800 A(80 A時); 1000 A(100 A時)
Conditional short-circuit current (Inc = IΔc)6000 A, 10000 A (with upstream SCPD)
インパルス耐量(Uimp)4 kV / 6 kV
Dielectric test voltage2.5 kV, 1 min
Tripping classesInstantaneous / Short time delay (10–300 ms) / Selective S (150–500 ms)
Break time under IΔn≤ 100 ms (Normal type)
Pollution degree2
Electrical life≥ 2000 operations
Mechanical life≥ 20000 operations
端子保護度IP20
周囲温度−25 °C to +55 °C (daily average ≤ 35 °C)
保存温度-40 °C ~ +70 °C
Terminal connectionケーブル / ピン型バスバー
Terminal size (cable)25–35 mm²; 18–3 / 18–2 AWG
Terminal size (busbar)10/16 mm²; 18–8 / 18–5 AWG
締め付けトルク2.5 N·m (≈ 22 in-lbs)
取り付けDIN rail EN 60715 (35 mm)
ConnectionTop and bottom
Waveform classType F (mixed-frequency residual currents)

アプリケーション

  • Inverter/UPS outputs, VFD-driven motors, appliances with mixed-frequency leakage
  • Residential, commercial, and light-industrial panels requiring タイプf rccb protection
  • Installations coordinated with upstream SCPD for 6/10 kA conditional ratings

type f rccb VKL11F Kuangya 2P/4P 16–100A 10/30/100/300 mA