KGLD Dual Power Automatic Transfer Switch (20–3200A)

Kuangya KGLD series isolated dual power automatic transfer switch (ATS), covering 20A–3200A, designed for reliable power grid ↔ generator changeover.

Features fast switching, integrated ATS controller, motor drive mechanism, high dielectric withstand, and >8000 operations lifespan.

Suitable for hospitals, banks, high-rise buildings, industrial plants, and other critical applications requiring uninterrupted power supply.

お見積もり

について KGLD Series Dual Power Automatic Transfer Switch (ATS) is a reliable dual power automatic transfer switch designed for switching between main and standby power or grid and generator.
With a compact design, high switching speed, and compliance with IEC 60947-6-1, the KGLD series ensures stable operation in critical facilities.
It provides automatic transfer, electrical and mechanical interlock, and an optional forced “0” position for maintenance.

アプリケーション

  • Hospitals, banks, and data centers requiring continuous power

  • Industrial facilities using 自動転送スイッチ equipment

  • Residential and commercial buildings with dual source power supply

  • Generator backup systems with dual power automatic transfer switch

主な特徴

  • Wide current range: 20–1600A, suitable for various ATS switch applications

  • Rated working voltage: AC400V, insulation up to 1000V

  • High short-circuit capacity: up to 120kA

  • Fast switching: conversion time 0.45s–1.2s

  • IEC 60947-6-1 / GB/T14048.11 ATS規格に適合

  • Supports both manual and automatic transfer operation

  • Available in 3P and 4P models, ideal as a dual power automatic transfer switch for commercial and industrial projects

Main Technical Parameters

Rated Current (A)Rated Insulation Voltage Ui (V)Rated Impulse Withstand Voltage Uimp (kV)Rated Working Voltage Ue (V)AC-31A Rated Current (A)AC-35A Rated Current (A)AC-33A Rated Current (A)Rated Making CapacityRated Breaking CapacityRated Limited Short Circuit Capacity (kA)Rated Short-time Withstand Current (kA)Conversion Time I↔II (s)Control VoltageMotor Power Start (W)Motor Power Normal (W)Weight (kg)
207508AC40020202010 Ie8 Ie5070.45AC220300557.0
407508AC40040404010 Ie8 Ie5070.45AC220300557.0
637508AC40063636310 Ie8 Ie5070.45AC220300557.2
807508AC40080808010 Ie8 Ie5070.45AC220300557.2
1007508AC40010010010010 Ie8 Ie5070.45AC220300557.5
1257508AC40012512512510 Ie8 Ie5070.45AC220325627.5
1607508AC40016016016010 Ie8 Ie5070.45AC220335628.8
2507508AC40025025025010 Ie8 Ie5070.45AC220335629.0
4007508AC40040040040010 Ie8 Ie5090.6AC2203357416.5
6307508AC40063063063010 Ie8 Ie5090.6AC2203357417.0
800100012AC40080080080010 Ie8 Ie70131.2AC2204409032.0
1000100012AC4001000100080010 Ie8 Ie70261.2AC2204409836.0
1250100012AC4001250100080010 Ie8 Ie100501.2AC2204409840.0
1600100012AC40016001600100010 Ie8 Ie120501.2AC2204409843.0

Main Circuit Wiring

The KGLD automatic transfer switch provides multiple wiring modes depending on system design, including:

  • Economical connection type (below 100A)
  • Passive signal + active fire terminal connection mode (100–630A)
  • Fully automatic connection (160–1600A)
  • Full automatic “0” forced setting (both sources disconnected)
  • Generator signal output connection mode
  • Automatic + Manual (remote control)
  • Wiring with controller (100–1600A)

Detailed wiring diagrams are available in the product catalog and should be strictly followed during installation.

規格とコンプライアンス

The KGLD series conforms to the following international standards:

  • IEC 60947-1 / GB/T 14048.1 (Low-voltage switchgear and controlgear – General rules)
  • IEC 60947-3 / GB/T 14048.3 (Switch disconnectors, isolators, fuse-combination units)
  • IEC 60947-6-1 / GB/T 14048.11 (Automatic transfer switching equipment – ATS)
  • Certified for safety, performance, and long service life

セレクションガイド

When choosing a KGLD automatic transfer switch, consider the following factors:

  1. Rated Current (20A–1600A) → Select based on total load.
  2. ポール → 3P for three-phase three-wire, 4P for three-phase four-wire systems.
  3. Control Method → Automatic or manual; remote control optional.
  4. Conversion Time → 0.45s–1.2s depending on model.
  5. Short-circuit Capacity → Up to 120kA for larger ratings.
  6. Installation Method → Panel mounted or door-mounted handle.
  7. Standards & Certification → Verify IEC/GB conformity and project compliance.

よくあるご質問

What is the main difference between KGLD and KGQ2 series?

KGLD is motor-driven automatic ATS with wide current range (20–1600A), while KGQ2 focuses on molded case dual power switches with different application emphasis.

Can KGLD be used with a generator as backup?

Yes. It supports grid-to-generator transfer, with automatic voltage detection and secure switching.

Does KGLD support remote control?

Yes, wiring modes include manual remote control and controller-based operation for smart systems.

What is the service life of KGLD?

Mechanical endurance ≥8000 operations, electrical endurance ≥6000 operations under rated conditions.

Is it certified?

Yes, compliant with IEC 60947-6-1, IEC 60947-3, GB/T14048.11, and related standards.

レビュー

レビューはまだありません。

“KGLD Dual Power Automatic Transfer Switch (20–3200A)” の口コミを投稿します

メールアドレスが公開されることはありません。 が付いている欄は必須項目です