Date: September 28, 2025 · Publisher: Kuangya Blog
Legal Disclaimer: This article is for informational purposes only and does not constitute professional engineering advice. All designs must be reviewed and approved by a licensed professional engineer in accordance with applicable codes and standards before execution.
Safety: All work on electrical systems must be performed by qualified personnel following strict lockout-tagout (LOTO) procedures. No live-work instructions are provided.
Modern installations—especially those with VFDs, PV/ESS, and EV chargers—require a layered protection strategy that coordinates MCB/MCCB (overcurrent), RCCB/アールシーボ (shock/fire), エーエフディー (arc-faults), and AC SPDs / DC SPD (surges). This approach reduces nuisance tripping and blind spots while aligning with current standards for both AC and DC systems.
References: IEC (60364 series, product & installation standards) · IECウェブストア · NEC (NFPA) · UL Standards
Clear role boundaries for MCB/MCCB, RCD family (RCCB/RCBO), AFDD, and SPDs. Choose the right device for the right threat category.
装置 | Primary Function | Threat Mitigated | 代表的な場所 | Key Parameters | Standards (2025) |
---|---|---|---|---|---|
MCB / MCCB | Overcurrent protection (overload & short-circuit) | Thermal damage, conductor insulation failure | Service entrance / MSB; sub-distribution; final circuits | In; trip curve B/C/D; Icn / Icu / Ics; temperature derating | IEC 60898-1 (MCB); IEC 60947-2 (MCCB) |
RCCB | Residual-current protection (no overcurrent) | Electric shock / earth-fault fire | Upstream group protection in sub-DB/final circuits | Idn (10/30/100/300 mA); Type AC/A/F/B; Type S (selective) | IEC 61008-1; IEC 62423 (Type F/B) |
アールシーボ | Combined residual-current + overcurrent | 衝撃+過負荷/端子短絡 | Final circuits (replaces MCB + RCCB) | In; Idn ≤ 30 mA; curve B/C/D; Type A/F/B | IEC 61009-1; IEC 62423 (Type F/B) |
エーエフディー | Arc-fault detection & trip | Series/parallel arc faults (fire) | Final circuits with higher fire risk, often paired with MCB/RCBO | Detection algorithm, nuisance immunity, self-test/indication | IEC 62606; UL 1699 (AFCI, NA) |
SPD (AC) | Clamp surges in AC systems | Lightning/switching surges | Type 1/1+2: service entrance; Type 2: sub-DB; Type 3: point-of-use | Uc; Up; In/Iマックス (8/20); I小悪魔 (10/350); SCCR; coordination | IEC 61643-11 (AC) |
SPD (PV/DC) | Clamp surges in PV/ESS/EV DC circuits | Transient overvoltages on DC | PV combiner, ESS DC bus, DC charger interface | Uシーピーブイ/Uc; Up; In/Iマックス; polarity; earthing scheme | IEC 61643-31 (PV/DC) |
Design tip: Do not assume functional overlap—MCB/MCCB do not detect earth leakage; RCDs do not limit surges. Use each device for its specific threat and coordinate settings/selectivity across layers.
Major product standards for RCCB/RCBO updated in 2024; new AC SPD edition expected 2025—reference latest editions during design and submittals.
References: 国際電気標準会議 · NEC (NFPA) · UL Standards
Coordinate AC SPDs, RCCB/アールシーボそして エーエフディー across three layers to achieve safety and selectivity in low-voltage systems.
References: 国際電気標準会議 - NEC (NFPA) - UL Standards
Use DC-rated protection and DC SPD at each interface (array, DC bus/ESS, inverter/charger). Maintain correct polarity, short leads, and a consistent equipotential bonding network. Key standards reference: 国際電気標準会議.
Coordination tips: respect distance/decoupling between SPD stages; document cable lengths; confirm polarity and earthing scheme (TN/TT/IT) before energization.
Follow this workflow to size RCDs, アールシーボ, エーエフディー, and overcurrent/SPD devices for AC/DC systems. Use it with your one-line to keep selectivity and compliance.
Key standards reference: 国際電気標準会議.
Use this practical checklist to install and verify SPD, RCDs/RCBOsそして AFDDs while maintaining selectivity and compliance. For the latest normative guidance, refer to 国際電気標準会議.
メンテナンス schedule periodic inspection of RCD trip function, SPD indicators, tightening torque logs, and thermal scans on high-current joints. Update documentation after any device replacement.
Use this section to choose between RCCB そして アールシーボ types (A/F/B/S) and to deploy them with エーエフディー そして AC SPDs while keeping selectivity and uptime.
Key standard reference: see 国際電気標準会議. Always check the latest edition and the product datasheet of your specific device.
Prepare a complete package to support design review, construction, and handover. This improves compliance and speeds approvals for projects using アールシーボ, RCCB, エーエフディー, AC SPDsそして DC SPD. Key normative source: 国際電気標準会議.
ヒント Keep a revision-controlled PDF set for the submittal and a separate editable source set (CAD + calculation sheets). Update both after every approved change to avoid site/record mismatches.
Use this checklist to quickly diagnose nuisance trips, surge damage, and coordination issues in layered protection systems. For normative context, see 国際電気標準会議.
Quick win: Start from finals → SMDB → service when fault-finding. Isolate with RCBOs to avoid taking down healthy circuits; verify neutrals, bonding, and SPD lead dress before swapping hardware.
This section answers common design/installation questions for layered protection in LV systems. For normative guidance, see 国際電気標準会議. (Internal reading: RCCB, アールシーボ, エーエフディー, AC SPD, DC SPD.)
Shortcut: Design top-down (service → SMDB → finals) but commission bottom-up (finals → SMDB → service). This isolates faults and protects healthy circuits while you test.
Key standards reference: 国際電気標準会議.