現代の電気安全におけるRCCBとRCBOデバイスの不可欠な役割 — Traditional MCBs stop overcurrents, but they can’t save lives from lethal earth-leakage shock. This guide explains why RCCB is essential for life protection and how アールシーボ integrates leakage + overcurrent into one compact, circuit-level solution for homes, commercial sites, PV/ESS and EV charging.
The proliferation of electrical systems in modern buildings has elevated the importance of robust safety measures. While traditional Miniature Circuit Breakers (MCBs) have long provided essential protection against overcurrents, they are critically insufficient in mitigating the most lethal hazards: electric shock そして fires caused by earth leakage.
This report analyzes Residual Current Circuit Breakers (RCCBs) and Residual Current Circuit Breakers with Overcurrent Protection (RCBOs), highlighting the difference between RCCB and RCBO in terms of function, application, and compliance. Understanding these differences is essential for modern electrical safety design.
Correct application and regular testing of these devices, guided by IEC 61009, NEC, and related standards, are fundamental to building a secure and compliant electrical environment.
The history of electrical safety has evolved from basic fuses to advanced protective devices. Early systems used Miniature Circuit Breakers (MCBs) to protect against overcurrents caused by overloads or short circuits. MCBs use a thermal-magnetic trip mechanism to interrupt dangerous current surges and prevent cable overheating.
However, the tripping threshold of an MCB is typically in the ampere range, far too high to protect humans from lethal shock currents as low as 30 mA. This limitation left a critical vulnerability in electrical safety, necessitating the creation of Residual Current Devices.
A nuanced understanding of hazards explains why leakage protection is indispensable:
Residual Current Devices (RCDs), also known as RCCBs or GFCIs, were engineered to address these hazards. They automatically disconnect the power supply when they detect leakage currents, thereby preventing electrocution and reducing fire risk.
Today, international standards mandate RCD use in high-risk zones (bathrooms, outdoor circuits, EV chargers, PV installations). Their widespread adoption has significantly reduced fatal electrical injuries worldwide.
In a healthy single-phase circuit, the current in the live (phase) conductor equals the current in the neutral. If any difference arises, it means electricity is leaking — through damaged insulation, faulty equipment, or even the human body. This imbalance is called residual current, and it is precisely what an RCCB または アールシーボ detects to trip instantly.
Live current = Neutral current → Net current = 0 → No trip.
Live current ≠ Neutral current → Leakage to earth → Device trips.
At the heart of every RCD is a differential current transformer. The live and neutral conductors are wound on a toroidal core. In normal operation, their magnetic fields cancel out. During leakage, an imbalance induces a voltage in a sensing coil, activating a relay that forces the breaker contacts open.
This progression reflects how IEC & UL standards evolved from property protection (fire prevention) to human life protection. The adoption of 30 mA RCCBs in residential and commercial buildings has dramatically reduced electrical fatalities.
A Residual Current Circuit Breaker (RCCB) is a dedicated earth-leakage protective device. It continuously monitors the balance between phase そして neutral currents and trips the circuit when an imbalance is detected, preventing electric shock そして leakage-caused fires.
An RCCB does not protect against overcurrent or short circuit. A high but balanced fault current (with no leakage) will not trip an RCCB. Consequently, an RCCB must be paired with a Miniature Circuit Breaker or fuse. This limitation defines a key part of the RCCB vs RCBO difference: while RCCBs focus solely on earth-leakage protection, RCBOs integrate both leakage and overcurrent protection in a single device.
Design tip: Use an RCBO-per-circuit layout to localize faults and avoid nuisance-wide outages.
Design tip: 用途 アールシーボ when you need both leakage and overcurrent protection on a single final circuit to avoid nuisance-wide outages and save space.
A Residual Current Circuit Breaker with Overcurrent Protection (RCBO) combines the RCCB’s leakage detection with the MCB’s overcurrent trip in a single device. This “all-in-one” unit provides comprehensive protection against electric shock, overload, and short circuit, making it a preferred choice in modern installations.
Uses a differential current transformer to detect leakage imbalance. Trips within < 30–40 ms to prevent electrocution.
サーマルエレメント(バイメタルストリップ)は過負荷で曲がります、 磁気コイルは短絡→断線に瞬時に反応します。
業界の動向 多くの商業用および住宅用プロジェクトは、次のように移行している。 メインRCCB1個+MCB複数個から 個々のRCBO 回路あたり 回復力を確保し、迷惑なトリップを最小限に抑える。
のどちらかを選択する。 エムシービー, RCCBそして アールシーボ そのためには、それぞれの機能を明確に理解する必要がある。 以下の表は、その主な違いを示している:
特徴 | エムシービー | RCCB | アールシーボ |
---|---|---|---|
主な目的 | 過負荷や短絡から配線を保護 | 漏電による感電や火災から人を守る | 総合:漏電+過負荷+短絡 |
何を検知するか | 過電流(熱+磁気) | 電流アンバランス(残留電流) | インバランスと過電流の両方 |
保護 | ケーブルの過熱、機器の損傷 | 感電、漏電による火災 | 衝撃、火災、過負荷、短絡 |
必要スペース | 1モジュール | 2-4モジュール | 1-2モジュール |
追加デバイスの必要性 | あり(漏電のためRCCBが必要) | あり(過電流用MCBが必要) | なし(自給自足) |
重要な洞察 現代の実務では、多くのプロジェクトが、次のような方向にシフトしている。 RCBO-per-circuit アーキテクチャー これにより、1つのRCCBでビル全体の電力を遮断するような迷惑なトリップを避けることができます、 代わりに、影響を受ける回路のみに保護を局所化します。
すべてではない RCCB または RCBOs 同じ故障波形を検出する。 より多くの インバーター、EV充電器、ドライブ 使用時には、正しいタイプの漏電遮断器を選ぶことが重要です。
純粋な正弦波ACのみを検出。抵抗負荷(ヒーター、オーブン)に適しています。
AC+脈動DCを検出。電子機器(洗濯機、調光器)のある回路に必要。
AC、脈動DC、スムーズDCを検出。 EV充電器、PVインバーター、VFDに不可欠.
複合電流の場合、例えば可変速モーターを備えた電化製品。
時間遅延による選択型。調整用カスケード保護に使用。
⚠️ 誤ったタイプ(例えば、EV充電器のACタイプ)を使用すると、システムが故障する可能性がある。 直流障害に無防備. 漏電遮断器のタイプは、必ず負荷の特性に合わせます。
漏電保護装置(RCCB/RCBO)は検出できません。 アークフォルト 接続の緩みやワイヤの損傷が原因。 これらのアークは 10,000°F標準的なブレーカーを落とすことなく、断熱材や木材に引火する。 これに対処するために アークフォルト検出装置(AFDD) が開発された。
特徴 | アールシーボ | エーエフディー |
---|---|---|
主な目的 | 衝撃と過電流から保護 | アークフォルトによる火災を防止 |
何を検知するか | 残留電流、過負荷、短絡 | 電気波形におけるアークの「シグネチャー |
検出メカニズム | 差動トランス+サーマル/マグネティック | 波形を解析するマイクロプロセッサー |
シナジー | 衝撃と電流の危険 | アーク火災をカバーすることでRCBOを補完 |
✅ 重層システム(RCBO+AFDD)は、最も完全な保護を提供する: RCBO = 衝撃と電流 | AFDD = アーク火災. 現在、多くの新しい建築基準法では、その両方が義務付けられている。
バスルーム、キッチン、屋外コンセント、ランドリールーム、地下室には30mAのRCCB/RCBOが必要。 寝室や居住空間では、アーク火災のリスクを軽減するためにAFDDを採用するケースが増えている。
厨房、調理ゾーン、屋上空調、屋外照明はRCBOを使用する。 ITルームとサーバーラックは、UPSとVFDが存在するため、タイプBのRCBOが有効である。
可変周波数ドライブ(VFD)、UPSシステム、充電装置にはタイプBのRCBOが必要です。 長いケーブル配線や屋外フィーダは、アークフォルト保護用のAFDDと組み合わせるのが最適です。
EV充電器には、タイプBまたは同等の直流感応装置が必要である。 PVおよびESSシステムは、インバータ回路用に設計されたRCBOを使用し、系統連系コードに準拠する必要がある。
RCCBとRCBOは、「設置して終わり」の装置ではない。その性能は、定期的なテストと検査にかかっている:
調査によると、漏電遮断器の適切な設置およびメンテナンスにより、職場での死亡事故が大幅に減少しています。 施設が必要な保護を欠いたり、定期的な機器のテストを怠ったりした場合、法的責任が適用される可能性があります。
残留電流サーキットブレーカ(RCCB)および過電流保護付き残留電流サーキットブレーカ(RCBO)は、オプションの追加ではなく、現代の低電圧安全の基礎です。 オプションの追加ではなく、最新の低電圧安全の基礎です。RCCB は、過電流専用デバイスが残した生命安全のギャップを埋めるものです。 RCCBは、危険な漏電を数十ミリ秒以内に遮断することで、過電流専用機器に残された生命安全のギャップを埋めます。RCBOは、漏電 漏電、過負荷、短絡の各機能を単一の回路レベルのデバイスに統合することで、この保護機能を拡張します。 回復力を高め、配線を簡素化し、迷惑な停電を減らします。
正しい選択 漏電遮断器タイプ (AC、A、B、F、S)は、EV充電器、PVインバータ、UPSシステム、可変速ドライブが複雑な残留電流波形を導入するようになった現在、設計上不可欠なものとなっています、 UPSシステム、可変速ドライブが複雑な残留電流波形を導入するためです。アークフォルトが懸念される場合 AFDDs を補完する独立した防火レイヤーを追加する。 アールシーボ 衝撃および過電流保護。これらのデバイスを組み合わせることで は、現代の規範とベストプラクティスに沿った重層的な防御を実施します。
設計者、請負業者、施設管理者にとって、進むべき道は明確である。 30 mA 個人保護 必要に応じて最終回路に個人保護装置を使用する。 タイプB 直流漏れや高周波漏れの可能性がある場合は、以下のように実装する。 RCBO-per-circuit アーキテクチャーで故障を特定し、スケジュールを立てる 定期的な機能テスト プロフェッショナルな 検査。これらのステップにより、コンプライアンスを測定可能なリスク削減と運用アップタイムに変換します。