VRL11 RCBO - Unipolaire + Neutre (1P+N) 5-40A

  • rcbo unipolaire (1P+N) modular RCBO for single-phase branches, Dans 5-40A, courbes B/C.

  • Type AC / Type A, sensibilités IΔn 6 / 10 / 30 / 100 / 300 mA; Icn 10 kA @ 240 V / 15 kA @ 120 V.

  • IEC/EN 61009-1 compliant; certified SEMKO / UKCA / CE / SAA.

Obtenir un devis

Catégorie :

rcbo unipolaire VRL11 integrates residual-current and overcurrent protection in a compact 1P+N footprint for single-phase boards, covering 5–40 A with Type AC/A residual protection and B/C tripping curves.

Vue d'ensemble

VRL11 is designed for residential and commercial distribution branches where reliable
RCD + MCB functionality is required in minimal space. It supports 240 V and 120 V grids
with high breaking capacities (10 kA @ 240 V; 15 kA @ 120 V), multiple residual
sensitivities from 6 mA to 300 mA, and curve B/C options to coordinate with upstream devices.

Caractéristiques principales

  • Facteur de forme : 1P+N (single-pole + neutral), modular DIN-rail
  • Courant nominal (In) : 5-40 A
  • Tension nominale (Ue) : 240 V CA / AC 120 V, 50/60 Hz
  • Type de courant résiduel : Type AC / Type A
  • Sensibilité (IΔn) : 6 / 10 / 30 / 100 / 300 mA
  • Courbes de déclenchement : B (3-5×In), C (5-10×In)
  • Capacité de rupture (Icn) : 10 kA @ 240 V; 15 kA à 120 V
  • Front test button (T); front wiring; compact installation depth
  • Compliance & certification: IEC/EN 61009-1; SEMKO, UKCA, CE, SAA

RCBO Single Pole Technical Data — VRL11

ParamètresVRL11
Pôles1P+N (unipolaire + neutre)
Courant nominal (In)5-40 A
Tension nominale (Ue)AC 240 V / AC 120 V
Fréquence50/60 Hz
Type de courant résiduelType AC / Type A
Courant résiduel nominal (IΔn)6 / 10 / 30 / 100 / 300 mA
MCB tripping curveB : 3-5 × In ; C : 5-10 × In
Capacité de rupture (Icn)10 kA @ 240 V; 15 kA @ 120 V
InstallationRail DIN ; câblage frontal ; bouton de test (T)
Recommended useResidential & commercial lighting/socket branches up to 40 A
NormesIEC/EN 61009-1
CertificationsSEMKO, UKCA, CE, SAA

Applications

  • Apartments & houses: lighting and socket circuits (≤ 40 A)
  • Commercial offices & retail: small-load branches
  • Public facilities: admin rooms, classrooms, auxiliary circuits

Downloads & Images

rcbo single pole VRL11 1P+N, 5–40A, Type AC/A, IΔn 6/10/30/100/300 mA, Icn 10 kA @240 V / 15 kA @120 V

Normes et conformité

Conforms to IEC/EN 61009-1. Certified by SEMKO, UKCA, CE, SAA.
Always coordinate with upstream devices and follow local codes for selectivity and fault levels.

FAQ

What distinguishes VRL11 from other 1P+N RCBOs?

VRL11 targets 5–40 A single-phase circuits on both 240 V and 120 V grids with high Icn (10 kA / 15 kA), Type AC/A residual protection and curve B/C options.

Which sensitivity (IΔn) is typical for sockets and lighting?

30 mA is most common; 6–10 mA for higher touch-safety; 100–300 mA per coordination and code requirements.

How do I choose between curve B and curve C?

Use B (3–5×In) for resistive/lightly inductive loads; use C (5–10×In) for higher inrush (motors, transformers). Verify discrimination with upstream protection.

Avis

Il n’y a pas encore d’avis.

Soyez le premier à laisser votre avis sur “VRL11 RCBO — Single-Pole + Neutral (1P+N) 5–40A”

Votre adresse e-mail ne sera pas publiée. Les champs obligatoires sont indiqués avec *