Disjoncteur DC 4P 1000V 125A | KYDB-125-4P

  • Kuangya KYDB-125-4P is a disjoncteur dc 4p 1000v 125a, available in 63A / 80A / 100A / 125A.

  • Four-pole protection at 1000VDC with 6kA breaking capacity; Ui 690V, Uimp 6kV.

  • IEC 60947-2 compliant, DIN-rail installation for PV, ESS & industrial DC systems.

Obtenir un devis

Catégorie :

Vue d'ensemble

Le disjoncteur dc 4p 1000v 125a (model KYDB-125-4P) delivers heavy-duty four-pole DC protection for high-voltage PV combiner boxes, energy storage systems (ESS), and industrial DC distribution. Rated for 1000VDC and available in 63A / 80A / 100A / 125A, it provides reliable overload and short-circuit protection with a 6kA breaking capacity. Insulation performance is ensured by Ui 690V et Uimp 6kV, supporting long-term operation in demanding environments.

Caractéristiques principales

Spécifications

ModèleKYDB-125-4P
Pôles4P
Courant nominal (In)63A / 80A / 100A / 125A
Tension nominale (Ue)1000VDC
Rated Insulation Voltage (Ui)690V
Impulse Withstand Voltage (Uimp)6kV
Capacité de rupture (Icn/Ics)6kA / 6kA
Trip CharacteristicsC / D (thermal-magnetic)
Durée de vie mécanique20,000 operations
Durée de vie électrique2,000 operations
InstallationDIN-rail, width 72mm (18mm × 4 poles)
NormesIEC 60947-2, GB/T 14048.2

Wiring Diagram & Dimensions

125A-MCB DIMENSION

 

Applications

  • High-voltage PV combiner boxes and strings
  • Système de stockage d'énergie (ESS) Distribution de courant continu
  • Industrial DC control and distribution panels
  • Telecommunication and infrastructure DC power systems

FAQ

Q1: What is a dc circuit breaker 4p 1000v 125a?

A1: It is a four-pole miniature DC breaker rated at 1000VDC and up to 125A, designed to provide overload and short-circuit protection in high-voltage DC systems.

Q2: What current ratings are available?

A2: KYDB-125-4P supports 63A, 80A, 100A, and 125A.

Q3: What is the breaking capacity?

A3: The breaker offers a standard breaking capacity of 6kA (Icn/Ics).

Q4: Can it be used in PV and ESS systems?

A4: Yes, this disjoncteur dc 4p 1000v 125a is widely applied in Boîtes de raccordement PV et la distribution de courant continu de l'ESS.

Q5: Which standards does KYDB-125-4P comply with?

A5: It complies with IEC 60947-2, GB/T 14048.2, and meets CE & UL requirements.

Obtenir un devis

Contact Kuangya for datasheets, wiring diagrams, or OEM customization of KYDB-125-4P.

Nous contacter

Avis

Il n’y a pas encore d’avis.

Soyez le premier à laisser votre avis sur “DC Circuit Breaker 4P 1000V 125A | KYDB-125-4P”

Votre adresse e-mail ne sera pas publiée. Les champs obligatoires sont indiqués avec *