KY-40/G600 Dispositif de protection contre les surtensions en courant continu (Type 2, 600V)

  • Le 600v dc spd KY-40/G600 provides Type 2 surge protection for photovoltaic DC systems.
  • Compact DIN-rail design with status indication and optional alarm contacts, compliant with IEC 61643-31.
  • Suitable for PV combiner boxes and inverter DC terminals, with shared T2 wiring/dimension diagrams.
Obtenir un devis

Catégorie :

Vue d'ensemble

Le 600v dc spd KY-40/G600 is a Type 2 DC surge protective device conçu pour
Boîtes de raccordement PV, string inputs, and inverter DC terminals up to 600VDC.
It limits residual overvoltage caused by indirect lightning and switching surges, protecting PV equipment and cables.
Entièrement conforme à IEC 61643-31, CE, UKCA, and RoHS certifications.

Caractéristiques principales

Spécifications

TypeType 2 (T2)
Tension du système (Ucpv)600 V DC
Courant de décharge nominal (In)20 kA
Courant de décharge maximal (Imax)40 kA
Niveau de protection de la tension (Up)≤ 3.0 kV
Temps de réponse (ta)< 25 ns
Résistance aux courts-circuits des PV (Iscpv)20 kA
Mode de protection / TopologieType U
Contact d'alarme (en option)220V, 0.5A, NO/NC
Fusible amont recommandéLS7-50k (selon la fiche technique)
Câblage / Bornes6-35 mm² bornes à vis
MontageRail DIN 35 mm
Enceinte / InflammabilitéBoîtier en plastique, UL94-V0
Conditions de fonctionnement-40℃ ~ +70℃ ; ≤95% RH
Dimensions (L×H×P)36 × 83 × 67 mm
Normes et conformitéIEC 61643-31:2018, GB/T 18802.31, CE, UKCA, RoHS

Câblage et dimensions

Wiring diagram of 600v dc spd KY-40/G600 Type 2 surge protective device for solar photovoltaic systems
Schéma de câblage commun pour la série KY T2 (600V/1000V/1500V/2000V).
Dimension drawing of 600v dc spd KY-40/G600 Type 2 surge protective device for PV combiner box protection
Schéma dimensionnel partagé pour la série KY T2.

Applications

  • PV combiner boxes and inverter DC terminals operating at 600VDC.
  • Residential and small commercial rooftops requiring Type 2 surge protection.
  • Coordination with upstream fuses and disconnectors in distributed PV systems.

FAQs

Q1. When should I use a 600v dc spd Type 2 device in PV systems?

Use KY-40/G600 at PV string or inverter inputs to limit residual surge voltage from indirect lightning and switching events.

Q2. Can KY-40/G600 be installed inside a PV combiner box?

Yes. It is designed for PV combiner boxes and inverter DC terminals at 600VDC; follow the wiring diagram and datasheet terminals.

Q3. Does KY-40/G600 support remote alarm indication?

Yes. Alarm terminals (NO/NC) are reserved as per the datasheet, rated 220V 0.5A.

Q4. Which standards apply to KY-40/G600?

Les certifications IEC 61643-31, GB/T 18802.31, CE, UKCA et RoHS sont couvertes.

Request a Quote for 600v dc spd KY-40/G600