RCCB VFL008 - Disjoncteur à courant résiduel

  • Circuit breaker RCCB type protection for residential, commercial, and light-industrial systems

  • 2P/4P options, rated current 16–100 A, sensitivities 30/100/300 mA, Ue 240 V (2P) / 415 V (4P)

  • IEC/EN 61008-1 compliance, high endurance, DIN-rail mounting, CE & UKCA

Obtenir un devis

Catégorie :

Vue d'ensemble

The Kuangya VFL008 disjoncteur type rccb disconnects the circuit when residual current exceeds the
preset threshold, preventing electric shock and fire hazards due to insulation faults. Available in both 2-pole and
4-pole versions, this circuit breaker rccb type suits single-phase and three-phase distribution boards in homes,
offices, and light-industrial facilities.

Caractéristiques principales

  • Pôles : 2P / 4P
  • Rated current (In): 16, 25, 32, 40, 63, 80, 100 A
  • Rated sensitivity (IΔn): 30 / 100 / 300 mA
  • Rated voltage (Ue): 240 V~ (2P) / 415 V~ (4P)
  • Insulation voltage (Ui): 500 V |   Frequency: 50/60 Hz
  • Residual making & breaking (IΔm): 500 A (In 16-40 A) ; 630 A (63 A) ; 800 A (80 A) ; 1000 A (100 A)
  • Conditional short-circuit current (Inc = IΔc): 6 kA / 10 kA (with upstream SCPD coordination)
  • Impulse withstand (Uimp): 6 kV; Essai diélectrique : 2.5 kV (1 min)
  • Endurance: ≥20,000 mechanical / ≥2000 electrical operations
  • Protection des bornes : IP20; fault current indicator
  • En milieu ambiant : −25 °C to +55 °C (daily avg ≤ 35 °C); Stockage : −40 °C to +70 °C
  • Câblage : cable 25–35 mm² or pin-type busbar; top/bottom connection
  • Montage : DIN rail EN 60715 (35 mm), fast clip
  • Normes/Approbations : IEC/EN 61008-1; CE / UKCA

Données techniques

ModèleVFL008
Pôles2P, 4P
Courant nominal (In)16A, 25A, 32A, 40A, 63A, 80A, 100A
Sensibilité nominale (IΔn)30 mA, 100 mA, 300 mA
Tension nominale (Ue)2P: 240 V~; 4P: 415 V~
Insulation voltage (Ui)500 V
Rated frequency50/60 Hz
Residual making & breaking (IΔm)500 A (In = 16–40 A); 630 A (In = 63 A); 800 A (In = 80 A); 1000 A (In = 100 A)
Conditional short-circuit (Inc = IΔc)6000 A, 10000 A
Tripping time classesInstantaneous / Short time delay (10–300 ms) / Selective S (150–500 ms)
Break time under IΔn (Normal)≤ 100 ms
Impulse withstand (Uimp)6 kV
Dielectric test voltage2.5 kV (1 min)
Pollution degree2
Electrical life≥ 2000 operations
Mechanical life≥ 2000 operations
Terminal protection degreeIP20
Ambient temperature (avg ≤ 35 °C)−25 °C to +55 °C
Température de stockage−40 °C to +70 °C
Terminal connectionCâble / Barre collectrice à broches
Terminal size (cable)25–35 mm²; 18–3 / 18–2 AWG
Terminal size (busbar)10/16 mm²; 18–8 / 18–5 AWG
Tightening torque2.5 N·m (≈ 22 in-lbs)
MontageDIN rail EN 60715 (35 mm)
ConnexionTop and bottom
AgrémentsCE, UKCA

Applications

  • Residential distribution boards (30 mA additional protection)
  • Commercial buildings requiring coordinated leakage and short-circuit protection
  • Light-industrial panels; consider short-time-delay or S-selective per coordination study

circuit breaker rccb type VFL008 Kuangya 2P/4P 16–100A 30/100/300 mA

Avis

Il n’y a pas encore d’avis.

Soyez le premier à laisser votre avis sur “RCCB VFL008 — Residual Current Circuit Breaker”

Votre adresse e-mail ne sera pas publiée. Les champs obligatoires sont indiqués avec *